Detail
Článek
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Antibacterial activity of titanium dioxide and Ag-incorporated DLC thin films

Veronika Vymětalová, Miroslav Jelínek, Petr Písařík, Jan Mikšovský, Jan Remsa, Veronika Řasová

. 2016 ; 46 (3) : 65-68.

Jazyk angličtina Země Česko

Perzistentní odkaz   https://www.medvik.cz/link/bmc19015225

Titanium dioxide (TiO2) and Ag-incorporated diamond-like carbon (DLC) films were prepared on different substrates. The films were prepared by pulsed laser deposition (PLD). TiO2 and Ag were selected due to their potential values as biomaterials. Silver is effective against a wide range of spectrum including Gram-negative and Gram-positive bacteria and yeast. TiO2 and Ag-incorporated DLC thin films are suitable candidates for application on biomedical devices and implants due to their biocompatibility, chemical inertness, and mechanical properties. Thin films are widely used in coronary artery stents, dental implants, heart valves and other vascular devices. The microstructure and antibacterial properties of TiO2 and silver-doped diamond-like carbon (DLC) films have been investigated. The films structural quality was evaluated using SEM microscopy, AFM microscopy and Raman spectroscopy. The antibacterial activity was determined using Gram-negative bacteria Escherichia coli and Gram-positive bacteria Bacillus subtilis. Our results demonstrate that the TiO2, nitrogen doped titanium oxides TON and Ag-incorporated DLC films are potentially useful as biomedical materials having good antibacterial properties.

Bibliografie atd.

Literatura

000      
00000naa a2200000 a 4500
001      
bmc19015225
003      
CZ-PrNML
005      
20210629234513.0
007      
ta
008      
190428s2016 xr a f 000 0|eng||
009      
AR
040    __
$a ABA008 $d ABA008 $e AACR2 $b cze
041    0_
$a eng
044    __
$a xr
100    1_
$a Vymětalová, Veronika, $d 1966- $7 mzk2008448535 $u Czech Technical University in Prague, Faculty of Biomedical Engineering, Kladno, Czech Republic
245    10
$a Antibacterial activity of titanium dioxide and Ag-incorporated DLC thin films / $c Veronika Vymětalová, Miroslav Jelínek, Petr Písařík, Jan Mikšovský, Jan Remsa, Veronika Řasová
504    __
$a Literatura
520    9_
$a Titanium dioxide (TiO2) and Ag-incorporated diamond-like carbon (DLC) films were prepared on different substrates. The films were prepared by pulsed laser deposition (PLD). TiO2 and Ag were selected due to their potential values as biomaterials. Silver is effective against a wide range of spectrum including Gram-negative and Gram-positive bacteria and yeast. TiO2 and Ag-incorporated DLC thin films are suitable candidates for application on biomedical devices and implants due to their biocompatibility, chemical inertness, and mechanical properties. Thin films are widely used in coronary artery stents, dental implants, heart valves and other vascular devices. The microstructure and antibacterial properties of TiO2 and silver-doped diamond-like carbon (DLC) films have been investigated. The films structural quality was evaluated using SEM microscopy, AFM microscopy and Raman spectroscopy. The antibacterial activity was determined using Gram-negative bacteria Escherichia coli and Gram-positive bacteria Bacillus subtilis. Our results demonstrate that the TiO2, nitrogen doped titanium oxides TON and Ag-incorporated DLC films are potentially useful as biomedical materials having good antibacterial properties.
650    _2
$a lidé $7 D006801
650    12
$a oxidy $x terapeutické užití $7 D010087
650    12
$a titan $x terapeutické užití $7 D014025
650    _2
$a farmaceutická technologie $7 D013678
650    _2
$a lékové formy $7 D004304
650    _2
$a antibakteriální látky $x terapeutické užití $7 D000900
650    _2
$a specializované použití chemických látek $7 D020313
650    _2
$a stříbro $x terapeutické užití $7 D012834
650    _2
$a gramnegativní bakterie $7 D006090
700    1_
$a Jelínek, Miroslav, $d 1946- $7 mzk2005306629 $u Czech Technical University in Prague, Faculty of Biomedical Engineering, Kladno, Czech Republic
700    1_
$a Písařík, Petr $7 _AN101031 $u Czech Technical University in Prague, Faculty of Biomedical Engineering, Kladno, Czech Republic
700    1_
$a Mikšovský, Jan $7 _AN068528 $u Czech Technical University in Prague, Faculty of Biomedical Engineering, Kladno, Czech Republic
700    1_
$a Remsa, Jan $7 xx0194140 $u Czech Technical University in Prague, Faculty of Biomedical Engineering, Kladno, Czech Republic
700    1_
$a Řasová, Veronika $7 xx0256661 $u Czech Technical University in Prague, Faculty of Biomedical Engineering, Kladno, Czech Republic
773    0_
$t Lékař a technika $x 0301-5491 $g Roč. 46, č. 3 (2016), s. 65-68 $w MED00011033
856    41
$u https://ojs.cvut.cz/ojs/index.php/CTJ/article/view/4186/4042 $y plný text volně přístupný
910    __
$a ABA008 $b B 1367 $c 1071 b $y p $z 0
990    __
$a 20190428103001 $b ABA008
991    __
$a 20210629234509 $b ABA008
999    __
$a ok $b bmc $g 1398975 $s 1053703
BAS    __
$a 3
BMC    __
$a 2016 $b 46 $c 3 $d 65-68 $i 0301-5491 $m Lékař a technika $n Lék. tech. $x MED00011033
LZP    __
$c NLK183 $d 20210629 $a NLK 2019-15/dk

Citační ukazatele

Nahrávání dat...

Možnosti archivace

Nahrávání dat...