-
Something wrong with this record ?
Fast elastic registration of soft tissues under large deformations
I. Peterlík, H. Courtecuisse, R. Rohling, P. Abolmaesumi, C. Nguan, S. Cotin, S. Salcudean,
Language English Country Netherlands
Document type Journal Article, Research Support, Non-U.S. Gov't, Validation Study
- MeSH
- Algorithms MeSH
- Finite Element Analysis MeSH
- Biomechanical Phenomena MeSH
- Abdomen diagnostic imaging surgery MeSH
- Surgery, Computer-Assisted methods MeSH
- Elasticity Imaging Techniques * MeSH
- Humans MeSH
- Liver Diseases diagnostic imaging surgery MeSH
- Intraoperative Period MeSH
- Tomography, X-Ray Computed * MeSH
- Computer Simulation MeSH
- Cone-Beam Computed Tomography * MeSH
- Patient Positioning MeSH
- Radiographic Image Interpretation, Computer-Assisted methods MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
- Validation Study MeSH
A fast and accurate fusion of intra-operative images with a pre-operative data is a key component of computer-aided interventions which aim at improving the outcomes of the intervention while reducing the patient's discomfort. In this paper, we focus on the problematic of the intra-operative navigation during abdominal surgery, which requires an accurate registration of tissues undergoing large deformations. Such a scenario occurs in the case of partial hepatectomy: to facilitate the access to the pathology, e.g. a tumor located in the posterior part of the right lobe, the surgery is performed on a patient in lateral position. Due to the change in patient's position, the resection plan based on the pre-operative CT scan acquired in the supine position must be updated to account for the deformations. We suppose that an imaging modality, such as the cone-beam CT, provides the information about the intra-operative shape of an organ, however, due to the reduced radiation dose and contrast, the actual locations of the internal structures necessary to update the planning are not available. To this end, we propose a method allowing for fast registration of the pre-operative data represented by a detailed 3D model of the liver and its internal structure and the actual configuration given by the organ surface extracted from the intra-operative image. The algorithm behind the method combines the iterative closest point technique with a biomechanical model based on a co-rotational formulation of linear elasticity which accounts for large deformations of the tissue. The performance, robustness and accuracy of the method is quantitatively assessed on a control semi-synthetic dataset with known ground truth and a real dataset composed of nine pairs of abdominal CT scans acquired in supine and flank positions. It is shown that the proposed surface-matching method is capable of reducing the target registration error evaluated of the internal structures of the organ from more than 40 mm to less then 10 mm. Moreover, the control data is used to demonstrate the compatibility of the method with intra-operative clinical scenario, while the real datasets are utilized to study the impact of parametrization on the accuracy of the method. The method is also compared to a state-of-the art intensity-based registration technique in terms of accuracy and performance.
Department of Electrical Engineering University of British Columbia Vancouver BC Canada
ICube University of Strasbourg CNRS Strasbourg France
Institute of Computer Science Masaryk University Brno Czech Republic
Urology Department Vancouver General Hospital Vancouver BC Canada
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19028587
- 003
- CZ-PrNML
- 005
- 20190823131055.0
- 007
- ta
- 008
- 190813s2018 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.media.2017.12.006 $2 doi
- 035 __
- $a (PubMed)29414434
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Peterlík, Igor $u MIMESIS, Inria Nancy, France; ICube, University of Strasbourg, CNRS, Strasbourg, France; Institute of Computer Science, Masaryk University, Brno, Czech Republic. Electronic address: igor.peterlik@inria.fr.
- 245 10
- $a Fast elastic registration of soft tissues under large deformations / $c I. Peterlík, H. Courtecuisse, R. Rohling, P. Abolmaesumi, C. Nguan, S. Cotin, S. Salcudean,
- 520 9_
- $a A fast and accurate fusion of intra-operative images with a pre-operative data is a key component of computer-aided interventions which aim at improving the outcomes of the intervention while reducing the patient's discomfort. In this paper, we focus on the problematic of the intra-operative navigation during abdominal surgery, which requires an accurate registration of tissues undergoing large deformations. Such a scenario occurs in the case of partial hepatectomy: to facilitate the access to the pathology, e.g. a tumor located in the posterior part of the right lobe, the surgery is performed on a patient in lateral position. Due to the change in patient's position, the resection plan based on the pre-operative CT scan acquired in the supine position must be updated to account for the deformations. We suppose that an imaging modality, such as the cone-beam CT, provides the information about the intra-operative shape of an organ, however, due to the reduced radiation dose and contrast, the actual locations of the internal structures necessary to update the planning are not available. To this end, we propose a method allowing for fast registration of the pre-operative data represented by a detailed 3D model of the liver and its internal structure and the actual configuration given by the organ surface extracted from the intra-operative image. The algorithm behind the method combines the iterative closest point technique with a biomechanical model based on a co-rotational formulation of linear elasticity which accounts for large deformations of the tissue. The performance, robustness and accuracy of the method is quantitatively assessed on a control semi-synthetic dataset with known ground truth and a real dataset composed of nine pairs of abdominal CT scans acquired in supine and flank positions. It is shown that the proposed surface-matching method is capable of reducing the target registration error evaluated of the internal structures of the organ from more than 40 mm to less then 10 mm. Moreover, the control data is used to demonstrate the compatibility of the method with intra-operative clinical scenario, while the real datasets are utilized to study the impact of parametrization on the accuracy of the method. The method is also compared to a state-of-the art intensity-based registration technique in terms of accuracy and performance.
- 650 _2
- $a břicho $x diagnostické zobrazování $x chirurgie $7 D000005
- 650 _2
- $a algoritmy $7 D000465
- 650 _2
- $a biomechanika $7 D001696
- 650 _2
- $a počítačová simulace $7 D003198
- 650 12
- $a počítačová tomografie s kuželovým svazkem $7 D054893
- 650 12
- $a elastografie $7 D054459
- 650 _2
- $a analýza metodou konečných prvků $7 D020342
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a peroperační doba $7 D007432
- 650 _2
- $a nemoci jater $x diagnostické zobrazování $x chirurgie $7 D008107
- 650 _2
- $a polohování pacienta $7 D056888
- 650 _2
- $a rentgenový obraz - interpretace počítačová $x metody $7 D011857
- 650 _2
- $a chirurgie s pomocí počítače $x metody $7 D025321
- 650 12
- $a počítačová rentgenová tomografie $7 D014057
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 655 _2
- $a validační studie $7 D023361
- 700 1_
- $a Courtecuisse, Hadrien $u ICube, University of Strasbourg, CNRS, Strasbourg, France; MIMESIS, Inria Nancy, France.
- 700 1_
- $a Rohling, Robert $u Department of Electrical Engineering, University of British Columbia, Vancouver, BC, Canada.
- 700 1_
- $a Abolmaesumi, Purang $u Department of Electrical Engineering, University of British Columbia, Vancouver, BC, Canada.
- 700 1_
- $a Nguan, Christopher $u Urology Department, Vancouver General Hospital, Vancouver, BC, Canada.
- 700 1_
- $a Cotin, Stéphane $u MIMESIS, Inria Nancy, France; ICube, University of Strasbourg, CNRS, Strasbourg, France.
- 700 1_
- $a Salcudean, Septimiu $u Department of Electrical Engineering, University of British Columbia, Vancouver, BC, Canada.
- 773 0_
- $w MED00007107 $t Medical image analysis $x 1361-8423 $g Roč. 45, č. - (2018), s. 24-40
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/29414434 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20190813 $b ABA008
- 991 __
- $a 20190823131309 $b ABA008
- 999 __
- $a ok $b bmc $g 1433736 $s 1067047
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2018 $b 45 $c - $d 24-40 $e 20171220 $i 1361-8423 $m Medical image analysis $n Med Image Anal $x MED00007107
- LZP __
- $a Pubmed-20190813