• Je něco špatně v tomto záznamu ?

An improved design of a passive sampler for polar organic compounds based on diffusion in agarose hydrogel

J. Urík, B. Vrana,

. 2019 ; 26 (15) : 15273-15284. [pub] 20190330

Jazyk angličtina Země Německo

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc19034678

Grantová podpora
603437 FP7-ENV-2013
LM2015051 Ministerstvo Školství, Mládeže a Tělovýchovy
CZ.02.1.01/0.0/0.0/16_013/0001761 European Structural and Investment Funds, Operational Programme Research, Development, Education

E-zdroje Online Plný text

NLK ProQuest Central od 1997-03-01 do Před 1 rokem
Health & Medicine (ProQuest) od 1997-03-01 do Před 1 rokem
Public Health Database (ProQuest) od 1997-03-01 do Před 1 rokem

Passive samplers based on diffusive gradients in thin hydrogel films (DGT) were recently modified for sampling of polar organic compounds in water. However, since the sampling rates of the commonly used DGT design with the surface area of 3.1 cm2 are low, we propose to increase them by applying a two-sided design with a larger sampling surface area of 22.7 cm2. The sampler design consists of two sorptive hydrogel disks compressed between two diffusive hydrogel disk layers strengthened by nylon netting and held together by two stainless steel rings. Sorbent/water distribution coefficients (KSW) were determined, and the sampler was calibrated for monitoring 11 perfluoroalkyl substances and 12 pharmaceuticals and personal care products in water at laboratory conditions using a closed system with artificial flow generated by submersible pumps. A field performance test was conducted at five locations in the Morava River basin in Czech Republic. The median value of laboratory-derived sampling rates was 43 mL day-1 with extreme values of 2 mL day-1 and 90 mL day-1 for perfluorotridecanoic and perfluoroheptanoic acids, respectively. The log KSW values of tested compounds ranged from 3.18 to 5.47 L kg-1, and the estimated halftime to attain sampler-water equilibrium ranged from 2 days to more than 28 days, which is the maximum recommended exposure period, considering potential issues with the stability of hydrogel. The sampler can be used for assessment of spatial trends as well as estimation of aqueous concentration of investigated polar compounds.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc19034678
003      
CZ-PrNML
005      
20191010111840.0
007      
ta
008      
191007s2019 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1007/s11356-019-04843-6 $2 doi
035    __
$a (PubMed)30929173
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Urík, Jakub $u Faculty of Science, Research Centre for Toxic Compounds in the Environment (RECETOX), Masaryk University, Kamenice 753/5, Pavilon A29, 625 00, Brno, Czech Republic.
245    13
$a An improved design of a passive sampler for polar organic compounds based on diffusion in agarose hydrogel / $c J. Urík, B. Vrana,
520    9_
$a Passive samplers based on diffusive gradients in thin hydrogel films (DGT) were recently modified for sampling of polar organic compounds in water. However, since the sampling rates of the commonly used DGT design with the surface area of 3.1 cm2 are low, we propose to increase them by applying a two-sided design with a larger sampling surface area of 22.7 cm2. The sampler design consists of two sorptive hydrogel disks compressed between two diffusive hydrogel disk layers strengthened by nylon netting and held together by two stainless steel rings. Sorbent/water distribution coefficients (KSW) were determined, and the sampler was calibrated for monitoring 11 perfluoroalkyl substances and 12 pharmaceuticals and personal care products in water at laboratory conditions using a closed system with artificial flow generated by submersible pumps. A field performance test was conducted at five locations in the Morava River basin in Czech Republic. The median value of laboratory-derived sampling rates was 43 mL day-1 with extreme values of 2 mL day-1 and 90 mL day-1 for perfluorotridecanoic and perfluoroheptanoic acids, respectively. The log KSW values of tested compounds ranged from 3.18 to 5.47 L kg-1, and the estimated halftime to attain sampler-water equilibrium ranged from 2 days to more than 28 days, which is the maximum recommended exposure period, considering potential issues with the stability of hydrogel. The sampler can be used for assessment of spatial trends as well as estimation of aqueous concentration of investigated polar compounds.
650    _2
$a difuze $7 D004058
650    _2
$a fluorokarbony $x chemie $7 D005466
650    _2
$a kyseliny heptylové $x chemie $7 D006538
650    _2
$a hydrogely $x chemie $7 D020100
650    _2
$a organické látky $x chemie $7 D009930
650    _2
$a řeky $x chemie $7 D045483
650    _2
$a sefarosa $x chemie $7 D012685
650    _2
$a voda $7 D014867
650    _2
$a chemické látky znečišťující vodu $x analýza $7 D014874
651    _2
$a Česká republika $7 D018153
655    _2
$a časopisecké články $7 D016428
700    1_
$a Vrana, Branislav $u Faculty of Science, Research Centre for Toxic Compounds in the Environment (RECETOX), Masaryk University, Kamenice 753/5, Pavilon A29, 625 00, Brno, Czech Republic. vrana@recetox.muni.cz.
773    0_
$w MED00001558 $t Environmental science and pollution research international $x 1614-7499 $g Roč. 26, č. 15 (2019), s. 15273-15284
856    41
$u https://pubmed.ncbi.nlm.nih.gov/30929173 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20191007 $b ABA008
991    __
$a 20191010112259 $b ABA008
999    __
$a ok $b bmc $g 1451338 $s 1073228
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2019 $b 26 $c 15 $d 15273-15284 $e 20190330 $i 1614-7499 $m Environmental science and pollution research international $n Environ. sci. pollut. res. int. $x MED00001558
GRA    __
$a 603437 $p FP7-ENV-2013
GRA    __
$a LM2015051 $p Ministerstvo Školství, Mládeže a Tělovýchovy
GRA    __
$a CZ.02.1.01/0.0/0.0/16_013/0001761 $p European Structural and Investment Funds, Operational Programme Research, Development, Education
LZP    __
$a Pubmed-20191007

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...