Je něco špatně v tomto záznamu ?
The effect of polymeric membrane surface on HaCaT cell properties
T. Kobiela, M. Milner-Krawczyk, E. Łukowska, P. Dobrzyński, M. Pastusiak, A. Smola-Dmochowska, J. Lukes, K. Bobecka-Wesołowska, A. Chwojnowski,
Jazyk angličtina Země Anglie, Velká Británie
Typ dokumentu časopisecké články
- MeSH
- buněčné linie MeSH
- fluorescenční mikroskopie MeSH
- keratinocyty účinky léků fyziologie MeSH
- lidé MeSH
- membrány chemie MeSH
- mikroskopie atomárních sil MeSH
- polymery chemická syntéza toxicita MeSH
- povrchové vlastnosti * MeSH
- testování materiálů * MeSH
- viabilita buněk MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
The control of the surface properties is an important issue for applicability of polymer membranes interacting with cells. In this work, the influence of surface roughness and stiffness of two polymer membranes on viability and mechanical properties of keratinocytes was studied. Terpolimer polyglicolide, polycaprolactone and polylactide, (PGA-PCL-PLA) and copolymer polycaprolactone, polyglicolide (PGA-PCL) substrates were used for membranes fabrication. Surface modification - the hydrolysis of the obtained membranes was carried out. The analysis of membranes' surface properties revealed that RMS surface roughness and roughness factor of PGA-PCL-PLA membrane decreased after hydrolysis while its stiffness increased. In contrast, the PGA-PCL membrane stiffness was only slightly affected by NaOH treatment. Immortalized human keratinocytes (HaCaT) were grown under standard conditions on the surface of the studied membranes and characterized by means of atomic force microscopy and fluorescence microcopy. The results showed the substrate-dependent effect on cells' properties.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc18033797
- 003
- CZ-PrNML
- 005
- 20181016121428.0
- 007
- ta
- 008
- 181008s2017 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1016/j.micron.2017.07.006 $2 doi
- 035 __
- $a (PubMed)28759806
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Kobiela, Tomasz $u Institute of Biotechnology, Faculty of Chemistry, Warsaw University of Technology, Noakowskiego 3, 00-664 Warsaw, Poland. Electronic address: kobiela@ch.pw.edu.pl.
- 245 14
- $a The effect of polymeric membrane surface on HaCaT cell properties / $c T. Kobiela, M. Milner-Krawczyk, E. Łukowska, P. Dobrzyński, M. Pastusiak, A. Smola-Dmochowska, J. Lukes, K. Bobecka-Wesołowska, A. Chwojnowski,
- 520 9_
- $a The control of the surface properties is an important issue for applicability of polymer membranes interacting with cells. In this work, the influence of surface roughness and stiffness of two polymer membranes on viability and mechanical properties of keratinocytes was studied. Terpolimer polyglicolide, polycaprolactone and polylactide, (PGA-PCL-PLA) and copolymer polycaprolactone, polyglicolide (PGA-PCL) substrates were used for membranes fabrication. Surface modification - the hydrolysis of the obtained membranes was carried out. The analysis of membranes' surface properties revealed that RMS surface roughness and roughness factor of PGA-PCL-PLA membrane decreased after hydrolysis while its stiffness increased. In contrast, the PGA-PCL membrane stiffness was only slightly affected by NaOH treatment. Immortalized human keratinocytes (HaCaT) were grown under standard conditions on the surface of the studied membranes and characterized by means of atomic force microscopy and fluorescence microcopy. The results showed the substrate-dependent effect on cells' properties.
- 650 _2
- $a buněčné linie $7 D002460
- 650 _2
- $a viabilita buněk $7 D002470
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a keratinocyty $x účinky léků $x fyziologie $7 D015603
- 650 12
- $a testování materiálů $7 D008422
- 650 _2
- $a membrány $x chemie $7 D008566
- 650 _2
- $a mikroskopie atomárních sil $7 D018625
- 650 _2
- $a fluorescenční mikroskopie $7 D008856
- 650 _2
- $a polymery $x chemická syntéza $x toxicita $7 D011108
- 650 12
- $a povrchové vlastnosti $7 D013499
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Milner-Krawczyk, Małgorzata $u Institute of Biotechnology, Faculty of Chemistry, Warsaw University of Technology, Noakowskiego 3, 00-664 Warsaw, Poland.
- 700 1_
- $a Łukowska, Ewa $u Nałęcz Institute of Biocybernetics and Biomedical Engineering Polish Academy of Sciences, Trojdena 4, 109-02 Warsaw, Poland.
- 700 1_
- $a Dobrzyński, Piotr $u Centre of Polymer and Carbon Materials Polish Academy of Sciences, M. Curie-Skłodowskiej 34, 41-819 Zabrze, Poland.
- 700 1_
- $a Pastusiak, Małgorzata $u Centre of Polymer and Carbon Materials Polish Academy of Sciences, M. Curie-Skłodowskiej 34, 41-819 Zabrze, Poland.
- 700 1_
- $a Smola-Dmochowska, Anna $u Centre of Polymer and Carbon Materials Polish Academy of Sciences, M. Curie-Skłodowskiej 34, 41-819 Zabrze, Poland.
- 700 1_
- $a Lukes, Jaroslav $u Czech Technical University in Prague, Faculty of Mechanical Engineering, Technicka 4, 16607 Praha, Czechia.
- 700 1_
- $a Bobecka-Wesołowska, Konstancja $u Faculty of Mathematics and Information Science, Warsaw University of Technology, Koszykowa 75, 00-662 Warsaw, Poland.
- 700 1_
- $a Chwojnowski, Andrzej $u Nałęcz Institute of Biocybernetics and Biomedical Engineering Polish Academy of Sciences, Trojdena 4, 109-02 Warsaw, Poland.
- 773 0_
- $w MED00006023 $t Micron (Oxford, England 1993) $x 1878-4291 $g Roč. 101, č. - (2017), s. 162-169
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/28759806 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20181008 $b ABA008
- 991 __
- $a 20181016121926 $b ABA008
- 999 __
- $a ok $b bmc $g 1340298 $s 1030791
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2017 $b 101 $c - $d 162-169 $e 20170720 $i 1878-4291 $m Micron $n Micron $x MED00006023
- LZP __
- $a Pubmed-20181008