Effect of stenting on the near-infrared spectroscopy-derived lipid core burden index of carotid artery plaque
C. Štěchovský, P. Hájek, M. Horváth, J. Veselka,
Language English Country France
Document type Journal Article
- MeSH
- Plaque, Atherosclerotic * surgery MeSH
- Spectroscopy, Near-Infrared MeSH
- Ultrasonography, Interventional MeSH
- Humans MeSH
- Lipids MeSH
- Coronary Artery Disease * MeSH
- Predictive Value of Tests MeSH
- Carotid Stenosis * surgery MeSH
- Stents * MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
AIMS: Catheter-based intravascular near-infrared spectroscopy (NIRS) detects a lipid signal from atherosclerotic plaque. The aim of this study was to describe the effect of carotid artery stenting (CAS) on the lipid signal in a carotid stenosis. METHODS AND RESULTS: We performed NIRS combined with intravascular ultrasound (IVUS) during 120 CAS procedures. Minimal luminal area (MLA) and plaque burden (PB) at the site of MLA were measured with IVUS and lipid core burden index (LCBI), maximal LCBI in a 4 mm segment of the artery (LCBImax) and LCBI in a 4 mm segment at the site of MLA (LCBImla) with NIRS-derived chemograms. NIRS-IVUS imaging was performed at baseline, after stent implantation and after balloon post-dilatation. The most common lesion type was the fibrocalcific plaque (76%). Lipid-rich plaque (LCBImax ≥400) was present in 33% of carotid stenoses and in 20% at the site of MLA. Median MLA increased significantly from baseline to stent implantation (3.63 mm2 to 5.56 mm2, p<0.001) and to post-dilatation (5.56 mm2 to 12.03 mm2, p<0.001). Median LCBI, LCBImax and LCBImla significantly decreased from baseline to stent implantation: LCBI (60 to 8, p<0.001), LCBImax (294 to 60, p<0.001) and LCBImla (124 to 0, p<0.001). Post-dilatation of the stent had no further significant effect on median LCBI (8 to 5, p=0.890), LCBImax (60 to 50, p=0.690) and LCBImla (0 to 0, p=0.438). CONCLUSIONS: Carotid artery stenting significantly reduced the NIRS-derived lipid core burden index at the stented segment.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc19035155
- 003
- CZ-PrNML
- 005
- 20191011104402.0
- 007
- ta
- 008
- 191007s2019 fr f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.4244/EIJ-D-17-01054 $2 doi
- 035 __
- $a (PubMed)29957596
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a fr
- 100 1_
- $a Štěchovský, Cyril $u Department of Cardiology, Second Faculty of Medicine, Charles University, University Hospital Motol, Prague, Czech Republic.
- 245 10
- $a Effect of stenting on the near-infrared spectroscopy-derived lipid core burden index of carotid artery plaque / $c C. Štěchovský, P. Hájek, M. Horváth, J. Veselka,
- 520 9_
- $a AIMS: Catheter-based intravascular near-infrared spectroscopy (NIRS) detects a lipid signal from atherosclerotic plaque. The aim of this study was to describe the effect of carotid artery stenting (CAS) on the lipid signal in a carotid stenosis. METHODS AND RESULTS: We performed NIRS combined with intravascular ultrasound (IVUS) during 120 CAS procedures. Minimal luminal area (MLA) and plaque burden (PB) at the site of MLA were measured with IVUS and lipid core burden index (LCBI), maximal LCBI in a 4 mm segment of the artery (LCBImax) and LCBI in a 4 mm segment at the site of MLA (LCBImla) with NIRS-derived chemograms. NIRS-IVUS imaging was performed at baseline, after stent implantation and after balloon post-dilatation. The most common lesion type was the fibrocalcific plaque (76%). Lipid-rich plaque (LCBImax ≥400) was present in 33% of carotid stenoses and in 20% at the site of MLA. Median MLA increased significantly from baseline to stent implantation (3.63 mm2 to 5.56 mm2, p<0.001) and to post-dilatation (5.56 mm2 to 12.03 mm2, p<0.001). Median LCBI, LCBImax and LCBImla significantly decreased from baseline to stent implantation: LCBI (60 to 8, p<0.001), LCBImax (294 to 60, p<0.001) and LCBImla (124 to 0, p<0.001). Post-dilatation of the stent had no further significant effect on median LCBI (8 to 5, p=0.890), LCBImax (60 to 50, p=0.690) and LCBImla (0 to 0, p=0.438). CONCLUSIONS: Carotid artery stenting significantly reduced the NIRS-derived lipid core burden index at the stented segment.
- 650 12
- $a stenóza arteria carotis $x chirurgie $7 D016893
- 650 12
- $a nemoci koronárních tepen $7 D003324
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a lipidy $7 D008055
- 650 12
- $a aterosklerotický plát $x chirurgie $7 D058226
- 650 _2
- $a prediktivní hodnota testů $7 D011237
- 650 _2
- $a blízká infračervená spektroskopie $7 D019265
- 650 12
- $a stenty $7 D015607
- 650 _2
- $a intervenční ultrasonografie $7 D018084
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Hájek, Petr
- 700 1_
- $a Horváth, Martin
- 700 1_
- $a Veselka, Josef
- 773 0_
- $w MED00184784 $t EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology $x 1969-6213 $g Roč. 15, č. 3 (2019), s. e289-e296
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/29957596 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20191007 $b ABA008
- 991 __
- $a 20191011104822 $b ABA008
- 999 __
- $a ok $b bmc $g 1451815 $s 1073705
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2019 $b 15 $c 3 $d e289-e296 $e 20190612 $i 1969-6213 $m EuroIntervention $n EuroIntervention $x MED00184784
- LZP __
- $a Pubmed-20191007