• Je něco špatně v tomto záznamu ?

In-line coupling of supported liquid membrane extraction across nanofibrous membrane to capillary electrophoresis for analysis of basic drugs from undiluted body fluids

M. Dvořák, P. Kubáň,

. 2019 ; 40 (18-19) : 2398-2406. [pub] 20190104

Jazyk angličtina Země Německo

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc20006676

Grantová podpora
16-09135S Grant Agency of the Czech Republic - International
68081715 Czech Academy of Sciences - International

Planar polyamide 6 nanofibrous membrane was for the first time used in direct coupling of supported liquid membrane (SLM) extraction to CE analysis. Disposable microextraction device with the nanofibrous membrane was preassembled and stored for immediate use. The membrane in the device was impregnated with 1 µL of 1-ethyl-2-nitrobenzene and the device was subsequently filled with 10 µL of acceptor solution (10 mM HCl) and 15 µL of donor solution (sample). The device was in-line coupled to CE system for selective extraction and direct injection, separation and quantification of model basic drugs (nortriptyline, haloperidol, loperamide and papaverine) from standard saline solutions (150 mM NaCl) and from undiluted human body fluids (urine and blood plasma). Compared to standard polypropylene supporting material, the nanofibrous membrane demonstrated superior characteristics in terms of lower consumption of organic solvents, constant volumes of operational solutions, full transparency and possibility to preassemble the devices. Extraction parameters were better or comparable for the nanofibrous vs. the polypropylene membrane and the hyphenated SLM-CE method with the nanofibrous membrane was characterized by good repeatability (RSD ≤ 11.3%), linearity (r2 ≥ 0.9953; 0.5-20 mg/L), sensitivity (LOD ≤ 0.4 mg/L) and transfer (27-126%) of the basic drugs.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc20006676
003      
CZ-PrNML
005      
20200518132903.0
007      
ta
008      
200511s2019 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1002/elps.201800487 $2 doi
035    __
$a (PubMed)30580438
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Dvořák, Miloš $u Institute of Analytical Chemistry of the Czech Academy of Sciences, Brno, Czech Republic.
245    10
$a In-line coupling of supported liquid membrane extraction across nanofibrous membrane to capillary electrophoresis for analysis of basic drugs from undiluted body fluids / $c M. Dvořák, P. Kubáň,
520    9_
$a Planar polyamide 6 nanofibrous membrane was for the first time used in direct coupling of supported liquid membrane (SLM) extraction to CE analysis. Disposable microextraction device with the nanofibrous membrane was preassembled and stored for immediate use. The membrane in the device was impregnated with 1 µL of 1-ethyl-2-nitrobenzene and the device was subsequently filled with 10 µL of acceptor solution (10 mM HCl) and 15 µL of donor solution (sample). The device was in-line coupled to CE system for selective extraction and direct injection, separation and quantification of model basic drugs (nortriptyline, haloperidol, loperamide and papaverine) from standard saline solutions (150 mM NaCl) and from undiluted human body fluids (urine and blood plasma). Compared to standard polypropylene supporting material, the nanofibrous membrane demonstrated superior characteristics in terms of lower consumption of organic solvents, constant volumes of operational solutions, full transparency and possibility to preassemble the devices. Extraction parameters were better or comparable for the nanofibrous vs. the polypropylene membrane and the hyphenated SLM-CE method with the nanofibrous membrane was characterized by good repeatability (RSD ≤ 11.3%), linearity (r2 ≥ 0.9953; 0.5-20 mg/L), sensitivity (LOD ≤ 0.4 mg/L) and transfer (27-126%) of the basic drugs.
650    _2
$a elektroforéza kapilární $x přístrojové vybavení $x metody $7 D019075
650    _2
$a design vybavení $7 D004867
650    _2
$a lidé $7 D006801
650    _2
$a lineární modely $7 D016014
650    12
$a membrány umělé $7 D008567
650    _2
$a chemické modely $7 D008956
650    _2
$a nanovlákna $x chemie $7 D057139
650    _2
$a léčivé přípravky $x krev $x izolace a purifikace $x moč $7 D004364
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a senzitivita a specificita $7 D012680
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Kubáň, Pavel $u Institute of Analytical Chemistry of the Czech Academy of Sciences, Brno, Czech Republic.
773    0_
$w MED00001508 $t Electrophoresis $x 1522-2683 $g Roč. 40, č. 18-19 (2019), s. 2398-2406
856    41
$u https://pubmed.ncbi.nlm.nih.gov/30580438 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20200511 $b ABA008
991    __
$a 20200518132902 $b ABA008
999    __
$a ok $b bmc $g 1525534 $s 1096732
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2019 $b 40 $c 18-19 $d 2398-2406 $e 20190104 $i 1522-2683 $m Electrophoresis $n Electrophoresis $x MED00001508
GRA    __
$a 16-09135S $p Grant Agency of the Czech Republic $2 International
GRA    __
$a 68081715 $p Czech Academy of Sciences $2 International
LZP    __
$a Pubmed-20200511

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...