Detail
Article
Online article
FT
Medvik - BMC
  • Something wrong with this record ?

Distance-based paper device using polydiacetylene liposome as a chromogenic substance for rapid and in-field analysis of quaternary ammonium compounds

B. Chutvirasakul, N. Nuchtavorn, M. Macka, L. Suntornsuk,

. 2020 ; 412 (13) : 3221-3230. [pub] 20200402

Language English Country Germany

Document type Journal Article

Grant support
Grant no. PHD/0177/2558 Thailand Research Fund through the Royal Golden Jubilee Ph.D. Program, the Higher Education Commission and Mahidol University
19-02108S Czech Science Foundation

E-resources Online Full text

NLK ProQuest Central from 2011-01-01 to 1 year ago
Medline Complete (EBSCOhost) from 2003-01-01 to 1 year ago
Health & Medicine (ProQuest) from 2011-01-01 to 1 year ago

This work presents an affordable distance-based microfluidic paper-based device (μPAD), using polydiacetylene (PDA) liposome as a chromogenic substance with a smartphone-based photo editor, for rapid and in-field analysis of quaternary ammonium compounds (QACs) (e.g., didecyldimethylammonium chloride (DDAC), benzyldimethyltetradecyl ammonium chloride (BAC), and cetylpyridinium chloride (CPC)). In-field analysis of these compounds is important to ensure their antimicrobial activity and user safety since they are widely utilized as disinfectants in households and hospitals. The μPAD featured a thermometer-like shape consisting of a sample reservoir and a microchannel as the detection zone, which was pre-deposited with PDA liposome. The color change from blue to red appeared in the presence of QACs and the color bar lengths were proportional to the QAC concentrations. Reactions of QACs with the PDA required a specific pH range (from pH 4.0 to 10.0) and a readout time of 7 min. Analytical performance characteristics of the device were tested with DDAC, BAC, and CPC showing acceptable specificity, accuracy (96.1-109.4%), and precision (%RSDs ≤ 9.3%). Limits of detection and quantitation were in the ranges of 20 to 80 and 70 to 250 μM, respectively. Feasibility of the newly developed device was demonstrated for in-field analysis of QACs in fumigation solution providing comparable results with those obtained from a colorimetric assay (P > 0.05). The proposed device shows potentials for further applications of other analytes since it offers speed, simplicity, and affordability for in-field analysis, especially in remote areas where expertise, resources, and infrastructures are limited. Graphical abstract.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc20019242
003      
CZ-PrNML
005      
20201123123816.0
007      
ta
008      
201103s2020 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1007/s00216-020-02583-y $2 doi
035    __
$a (PubMed)32242258
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Chutvirasakul, Boonta $u Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Mahidol University, 447 Sri-Ayudhaya Rd., Rajathevee, Bangkok, 10400, Thailand. Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Srinakharinwirot University, 63 Moo 7 Rangsit-Nakornnayok Road, Ongkharak, Ongkharak, Nakornnayok, 26120, Thailand.
245    10
$a Distance-based paper device using polydiacetylene liposome as a chromogenic substance for rapid and in-field analysis of quaternary ammonium compounds / $c B. Chutvirasakul, N. Nuchtavorn, M. Macka, L. Suntornsuk,
520    9_
$a This work presents an affordable distance-based microfluidic paper-based device (μPAD), using polydiacetylene (PDA) liposome as a chromogenic substance with a smartphone-based photo editor, for rapid and in-field analysis of quaternary ammonium compounds (QACs) (e.g., didecyldimethylammonium chloride (DDAC), benzyldimethyltetradecyl ammonium chloride (BAC), and cetylpyridinium chloride (CPC)). In-field analysis of these compounds is important to ensure their antimicrobial activity and user safety since they are widely utilized as disinfectants in households and hospitals. The μPAD featured a thermometer-like shape consisting of a sample reservoir and a microchannel as the detection zone, which was pre-deposited with PDA liposome. The color change from blue to red appeared in the presence of QACs and the color bar lengths were proportional to the QAC concentrations. Reactions of QACs with the PDA required a specific pH range (from pH 4.0 to 10.0) and a readout time of 7 min. Analytical performance characteristics of the device were tested with DDAC, BAC, and CPC showing acceptable specificity, accuracy (96.1-109.4%), and precision (%RSDs ≤ 9.3%). Limits of detection and quantitation were in the ranges of 20 to 80 and 70 to 250 μM, respectively. Feasibility of the newly developed device was demonstrated for in-field analysis of QACs in fumigation solution providing comparable results with those obtained from a colorimetric assay (P > 0.05). The proposed device shows potentials for further applications of other analytes since it offers speed, simplicity, and affordability for in-field analysis, especially in remote areas where expertise, resources, and infrastructures are limited. Graphical abstract.
655    _2
$a časopisecké články $7 D016428
700    1_
$a Nuchtavorn, Nantana $u Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Mahidol University, 447 Sri-Ayudhaya Rd., Rajathevee, Bangkok, 10400, Thailand.
700    1_
$a Macka, Mirek $u Australian Centre for Research on Separation Science (ACROSS) and School of Natural Sciences, University of Tasmania, Private Bag 75, Hobart, 7001, Australia. Department of Chemistry and Biochemistry, Mendel University in Brno, Zemedelska 1, CZ-613 00, Brno, Czech Republic. Central European Institute of Technology, Brno University of Technology, Purkynova 123, CZ-612 00, Brno, Czech Republic.
700    1_
$a Suntornsuk, Leena $u Department of Pharmaceutical Chemistry, Faculty of Pharmacy, Mahidol University, 447 Sri-Ayudhaya Rd., Rajathevee, Bangkok, 10400, Thailand. leena.sun@mahidol.ac.th.
773    0_
$w MED00006638 $t Analytical and bioanalytical chemistry $x 1618-2650 $g Roč. 412, č. 13 (2020), s. 3221-3230
856    41
$u https://pubmed.ncbi.nlm.nih.gov/32242258 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20201103 $b ABA008
991    __
$a 20201123123815 $b ABA008
999    __
$a ind $b bmc $g 1586022 $s 1109440
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2020 $b 412 $c 13 $d 3221-3230 $e 20200402 $i 1618-2650 $m Analytical and bioanalytical chemistry $n Anal Bioanal Chem $x MED00006638
GRA    __
$a Grant no. PHD/0177/2558 $p Thailand Research Fund through the Royal Golden Jubilee Ph.D. Program, the Higher Education Commission and Mahidol University
GRA    __
$a 19-02108S $p Czech Science Foundation
LZP    __
$a Pubmed-20201103

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...