-
Something wrong with this record ?
Hemocompatibility Testing of Blood-Contacting Implants in a Flow Loop Model Mimicking Human Blood Flow
A. Link, G. Cattaneo, E. Brynda, T. Riedel, J. Kucerova, C. Schlensak, HP. Wendel, S. Krajewski, T. Michel,
Language English Country United States
Document type Journal Article, Research Support, Non-U.S. Gov't, Video-Audio Media
PubMed
32202530
DOI
10.3791/60610
Knihovny.cz E-resources
- MeSH
- beta-Thromboglobulin metabolism MeSH
- Biomarkers metabolism MeSH
- Models, Biological * MeSH
- Blood Vessel Prosthesis * MeSH
- Heparin pharmacology MeSH
- Immune System metabolism MeSH
- Complement System Proteins metabolism MeSH
- Blood Circulation drug effects physiology MeSH
- Blood Cell Count MeSH
- Plasma MeSH
- Humans MeSH
- Blood Specimen Collection MeSH
- Pancreatic Elastase metabolism MeSH
- Stents MeSH
- Materials Testing methods MeSH
- Check Tag
- Humans MeSH
- Publication type
- Video-Audio Media MeSH
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
The growing use of medical devices (e.g., vascular grafts, stents, and cardiac catheters) for temporary or permanent purposes that remain in the body's circulatory system demands a reliable and multiparametric approach that evaluates the possible hematologic complications caused by these devices (i.e., activation and destruction of blood components). Comprehensive in vitro hemocompatibility testing of blood-contacting implants is the first step towards successful in vivo implementation. Therefore, extensive analysis according to the International Organization for Standardization 10993-4 (ISO 10993-4) is mandatory prior to clinical application. The presented flow loop describes a sensitive model to analyze the hemostatic performance of stents (in this case, neurovascular) and reveal adverse effects. The use of fresh human whole blood and gentle blood sampling are essential to avoid the preactivation of blood. The blood is perfused through a heparinized tubing containing the test specimen by using a peristaltic pump at a rate of 150 mL/min at 37 °C for 60 min. Before and after perfusion, hematologic markers (i.e., blood cell count, hemoglobin, hematocrit, and plasmatic markers) indicating the activation of leukocytes (polymorphonuclear [PMN]-elastase), platelets (β-thromboglobulin [β-TG]), the coagulation system (thombin-antithrombin III [TAT]), and the complement cascade (SC5b-9) are analyzed. In conclusion, we present an essential and reliable model for extensive hemocompatibility testing of stents and other blood-contacting devices prior to clinical application.
Department of Thoracic Cardiac and Vascular Surgery University Hospital Tuebingen
Institute of Biomedical Engineering University of Stuttgart
Institute of Macromolecular Chemistry Academy of Sciences of the Czech Republic
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc20025148
- 003
- CZ-PrNML
- 005
- 20201222155102.0
- 007
- ta
- 008
- 201125s2020 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.3791/60610 $2 doi
- 035 __
- $a (PubMed)32202530
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Link, Antonia $u Department of Thoracic, Cardiac and Vascular Surgery, University Hospital Tuebingen.
- 245 10
- $a Hemocompatibility Testing of Blood-Contacting Implants in a Flow Loop Model Mimicking Human Blood Flow / $c A. Link, G. Cattaneo, E. Brynda, T. Riedel, J. Kucerova, C. Schlensak, HP. Wendel, S. Krajewski, T. Michel,
- 520 9_
- $a The growing use of medical devices (e.g., vascular grafts, stents, and cardiac catheters) for temporary or permanent purposes that remain in the body's circulatory system demands a reliable and multiparametric approach that evaluates the possible hematologic complications caused by these devices (i.e., activation and destruction of blood components). Comprehensive in vitro hemocompatibility testing of blood-contacting implants is the first step towards successful in vivo implementation. Therefore, extensive analysis according to the International Organization for Standardization 10993-4 (ISO 10993-4) is mandatory prior to clinical application. The presented flow loop describes a sensitive model to analyze the hemostatic performance of stents (in this case, neurovascular) and reveal adverse effects. The use of fresh human whole blood and gentle blood sampling are essential to avoid the preactivation of blood. The blood is perfused through a heparinized tubing containing the test specimen by using a peristaltic pump at a rate of 150 mL/min at 37 °C for 60 min. Before and after perfusion, hematologic markers (i.e., blood cell count, hemoglobin, hematocrit, and plasmatic markers) indicating the activation of leukocytes (polymorphonuclear [PMN]-elastase), platelets (β-thromboglobulin [β-TG]), the coagulation system (thombin-antithrombin III [TAT]), and the complement cascade (SC5b-9) are analyzed. In conclusion, we present an essential and reliable model for extensive hemocompatibility testing of stents and other blood-contacting devices prior to clinical application.
- 650 _2
- $a biologické markery $x metabolismus $7 D015415
- 650 _2
- $a krevní obraz $7 D001772
- 650 _2
- $a krevní oběh $x účinky léků $x fyziologie $7 D001775
- 650 _2
- $a odběr vzorku krve $7 D001800
- 650 12
- $a cévní protézy $7 D001807
- 650 _2
- $a komplement $x metabolismus $7 D003165
- 650 _2
- $a heparin $x farmakologie $7 D006493
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a imunitní systém $x metabolismus $7 D007107
- 650 _2
- $a testování materiálů $x metody $7 D008422
- 650 12
- $a biologické modely $7 D008954
- 650 _2
- $a pankreatická elastasa $x metabolismus $7 D010196
- 650 _2
- $a krevní plazma $7 D010949
- 650 _2
- $a stenty $7 D015607
- 650 _2
- $a beta-thromboglobulin $x metabolismus $7 D001620
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 655 _2
- $a audiovizuální média $7 D059040
- 700 1_
- $a Cattaneo, Giorgio $u Acandis GmbH; Institute of Biomedical Engineering, University of Stuttgart.
- 700 1_
- $a Brynda, Eduard $u Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic.
- 700 1_
- $a Riedel, Tomas $u Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic.
- 700 1_
- $a Kucerova, Johanka $u Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic.
- 700 1_
- $a Schlensak, Christian $u Department of Thoracic, Cardiac and Vascular Surgery, University Hospital Tuebingen.
- 700 1_
- $a Wendel, Hans Peter $u Department of Thoracic, Cardiac and Vascular Surgery, University Hospital Tuebingen.
- 700 1_
- $a Krajewski, Stefanie $u Department of Thoracic, Cardiac and Vascular Surgery, University Hospital Tuebingen.
- 700 1_
- $a Michel, Tatjana $u Department of Thoracic, Cardiac and Vascular Surgery, University Hospital Tuebingen; tatjana.michel@uni-tuebingen.de.
- 773 0_
- $w MED00190569 $t Journal of visualized experiments : JoVE $x 1940-087X $g č. 157 (2020)
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/32202530 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20201125 $b ABA008
- 991 __
- $a 20201222155058 $b ABA008
- 999 __
- $a ok $b bmc $g 1599293 $s 1115834
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $c 157 $e 20200305 $i 1940-087X $m Journal of visualized experiments $n J. vis. exp. $x MED00190569
- LZP __
- $a Pubmed-20201125