COMPARISON OF DIFFERENT TECHNIQUES FOR EVALUATION OF DOSE DISTRIBUTIONS IN RADIOTHERAPY USING RADIOCHROMIC EBT3 FILMS

V. Dufek, I. Horakova, I. Koniarova,

. 2019 ; 186 (2-3) : 357-361. [pub] 2019Dec31

Jazyk angličtina Země Velká Británie

Typ dokumentu srovnávací studie, hodnotící studie, časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc20025371

In radiotherapy, radiochromic films can be used for verification of delivery of dose distributions calculated by treatment planning systems. The main objective of this work was to compare three different techniques for evaluation of dose distributions for prostate cancer treatment plans using radiochromic EBT3 films. These techniques are: red channel evaluation taking into account only a response of irradiated film (R), red channel evaluation taking into account a response of unirradiated and irradiated film (Rcor) and multichannel evaluation in FilmQA software (RGB). Also comparison between film and MatriXX measurement was performed. Comparison showed that gamma analysis passing rates strongly depend on evaluation technique and on a model of scanner for digitizing films. The highest gamma passing rates were obtained with red channel evaluation taking into account a response of unirradiated and irradiated film using Epson V750 scanner (Rcor) and multichannel evaluation in FilmQA using Epson 11000XL scanner.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc20025371
003      
CZ-PrNML
005      
20201222153851.0
007      
ta
008      
201125s2019 xxk f 000 0|eng||
009      
AR
024    7_
$a 10.1093/rpd/ncz231 $2 doi
035    __
$a (PubMed)31711200
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Dufek, V $u Medical Exposure Section, National Radiation Protection Institute, Prague, Czech Republic. Department of Radiological Physics, Na Bulovce Hospital, Prague, Czech Republic.
245    10
$a COMPARISON OF DIFFERENT TECHNIQUES FOR EVALUATION OF DOSE DISTRIBUTIONS IN RADIOTHERAPY USING RADIOCHROMIC EBT3 FILMS / $c V. Dufek, I. Horakova, I. Koniarova,
520    9_
$a In radiotherapy, radiochromic films can be used for verification of delivery of dose distributions calculated by treatment planning systems. The main objective of this work was to compare three different techniques for evaluation of dose distributions for prostate cancer treatment plans using radiochromic EBT3 films. These techniques are: red channel evaluation taking into account only a response of irradiated film (R), red channel evaluation taking into account a response of unirradiated and irradiated film (Rcor) and multichannel evaluation in FilmQA software (RGB). Also comparison between film and MatriXX measurement was performed. Comparison showed that gamma analysis passing rates strongly depend on evaluation technique and on a model of scanner for digitizing films. The highest gamma passing rates were obtained with red channel evaluation taking into account a response of unirradiated and irradiated film using Epson V750 scanner (Rcor) and multichannel evaluation in FilmQA using Epson 11000XL scanner.
650    _2
$a algoritmy $7 D000465
650    _2
$a kalibrace $7 D002138
650    _2
$a filmová dozimetrie $x přístrojové vybavení $x metody $7 D005373
650    _2
$a záření gama $7 D005720
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    12
$a fantomy radiodiagnostické $7 D019047
650    _2
$a nádory prostaty $x radioterapie $7 D011471
650    _2
$a celková dávka radioterapie $7 D011879
650    _2
$a plánování radioterapie pomocí počítače $x metody $7 D011880
650    _2
$a radioterapie s modulovanou intenzitou $x metody $7 D050397
655    _2
$a srovnávací studie $7 D003160
655    _2
$a hodnotící studie $7 D023362
655    _2
$a časopisecké články $7 D016428
700    1_
$a Horakova, I $u Medical Exposure Section, National Radiation Protection Institute, Prague, Czech Republic.
700    1_
$a Koniarova, I $u Medical Exposure Section, National Radiation Protection Institute, Prague, Czech Republic.
773    0_
$w MED00004029 $t Radiation protection dosimetry $x 1742-3406 $g Roč. 186, č. 2-3 (2019), s. 357-361
856    41
$u https://pubmed.ncbi.nlm.nih.gov/31711200 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20201125 $b ABA008
991    __
$a 20201222153847 $b ABA008
999    __
$a ok $b bmc $g 1599516 $s 1116057
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2019 $b 186 $c 2-3 $d 357-361 $e 2019Dec31 $i 1742-3406 $m Radiation protection dosimetry $n Radiat Prot Dosimetry $x MED00004029
LZP    __
$a Pubmed-20201125

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...