Emerging investigator series: air conditioning filters as a sampler for semi-volatile organic compounds in indoor and near-building air

SR. Jílková, L. Melymuk, J. Klánová,

. 2020 ; 22 (12) : 2322-2331. [pub] 2020Dec16

Language English Country Great Britain

Document type Journal Article

Organic compounds like flame retardants (FRs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs) and polycyclic aromatic hydrocarbons (PAHs) are consistently found in both indoor and outdoor environments. There are many possible matrices for measurement of these compounds (e.g. indoor dust, air - passive and active air samples), but all methods have limitations, like the heterogeneous distribution of indoor dust, or noisy active air samplers. We used filters from building-wide heating, ventilation and air conditioning (HVAC) units to evaluate levels of PAHs, PCBs, OCPs and NFRs in indoor and outdoor environments, and to evaluate whether this method is feasible for screening semivolatile organic compounds (SVOCs) in indoor and near-building outdoor environments. Detectable levels of FRs, PCBs, OCPs and PAHs were found, demonstrating that HVAC filters do collect SVOCs, with generally higher levels of PAHs in the incoming air filters and higher levels of PCBs, OCPs and FRs in the outgoing air filters. Levels of FRs, PCBs and OCPs in outgoing air were comparable to those measured using conventional active air sampling in the same building. The advantages of using HVAC filters are (1) integrated and homogeneous samples, as the whole building is sampled over typically a long timescale (months), and (2) samples are easy and cheap to collect and do not require prior deployment of samplers. The key disadvantage is that HVAC filters are not designed for analytical chemistry and thus the filter materials can have variable or unknown gas sorption and particle capture, and can have strong matrix effects during analysis.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc20027575
003      
CZ-PrNML
005      
20210114152109.0
007      
ta
008      
210105s2020 xxk f 000 0|eng||
009      
AR
024    7_
$a 10.1039/d0em00284d $2 doi
035    __
$a (PubMed)33130833
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxk
100    1_
$a Jílková, Simona Rozárka $u RECETOX, Masaryk University, Brno, Czech Republic. lisa.melymuk@recetox.muni.cz.
245    10
$a Emerging investigator series: air conditioning filters as a sampler for semi-volatile organic compounds in indoor and near-building air / $c SR. Jílková, L. Melymuk, J. Klánová,
520    9_
$a Organic compounds like flame retardants (FRs), polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs) and polycyclic aromatic hydrocarbons (PAHs) are consistently found in both indoor and outdoor environments. There are many possible matrices for measurement of these compounds (e.g. indoor dust, air - passive and active air samples), but all methods have limitations, like the heterogeneous distribution of indoor dust, or noisy active air samplers. We used filters from building-wide heating, ventilation and air conditioning (HVAC) units to evaluate levels of PAHs, PCBs, OCPs and NFRs in indoor and outdoor environments, and to evaluate whether this method is feasible for screening semivolatile organic compounds (SVOCs) in indoor and near-building outdoor environments. Detectable levels of FRs, PCBs, OCPs and PAHs were found, demonstrating that HVAC filters do collect SVOCs, with generally higher levels of PAHs in the incoming air filters and higher levels of PCBs, OCPs and FRs in the outgoing air filters. Levels of FRs, PCBs and OCPs in outgoing air were comparable to those measured using conventional active air sampling in the same building. The advantages of using HVAC filters are (1) integrated and homogeneous samples, as the whole building is sampled over typically a long timescale (months), and (2) samples are easy and cheap to collect and do not require prior deployment of samplers. The key disadvantage is that HVAC filters are not designed for analytical chemistry and thus the filter materials can have variable or unknown gas sorption and particle capture, and can have strong matrix effects during analysis.
650    _2
$a klimatizace $7 D000389
650    12
$a vzduchové filtry $7 D061808
650    12
$a látky znečišťující vzduch $x analýza $7 D000393
650    12
$a znečištění vzduchu ve vnitřním prostředí $x analýza $7 D016902
650    _2
$a monitorování životního prostředí $7 D004784
650    12
$a retardanty hoření $x analýza $7 D005411
650    12
$a polychlorované bifenyly $x analýza $7 D011078
650    12
$a polycyklické aromatické uhlovodíky $x analýza $7 D011084
650    12
$a těkavé organické sloučeniny $x analýza $7 D055549
655    _2
$a časopisecké články $7 D016428
700    1_
$a Melymuk, Lisa $u RECETOX, Masaryk University, Brno, Czech Republic. lisa.melymuk@recetox.muni.cz.
700    1_
$a Klánová, Jana $u RECETOX, Masaryk University, Brno, Czech Republic. lisa.melymuk@recetox.muni.cz.
773    0_
$w MED00184537 $t Environmental science. Processes & impacts $x 2050-7895 $g Roč. 22, č. 12 (2020), s. 2322-2331
856    41
$u https://pubmed.ncbi.nlm.nih.gov/33130833 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y a $z 0
990    __
$a 20210105 $b ABA008
991    __
$a 20210114152108 $b ABA008
999    __
$a ok $b bmc $g 1607910 $s 1118755
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2020 $b 22 $c 12 $d 2322-2331 $e 2020Dec16 $i 2050-7895 $m Environmental science. Processes & impacts $n Environ Sci Process Impacts $x MED00184537
LZP    __
$a Pubmed-20210105

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...