Je něco špatně v tomto záznamu ?
Ankle-foot orthosis design between the tradition and the computerized perspectives
A. Darwich, H. Nazha, A. Sliman, W. Abbas,
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články
PubMed
31782688
DOI
10.1177/0391398819890348
Knihovny.cz E-zdroje
- MeSH
- analýza metodou konečných prvků MeSH
- biomechanika MeSH
- chůze fyziologie MeSH
- design s pomocí počítače MeSH
- design vybavení metody MeSH
- hlezenní kloub fyziologie MeSH
- lidé MeSH
- neurologické poruchy chůze * etiologie patofyziologie terapie MeSH
- ortézy nohy (od hlezna dolů) * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
This study focuses on the drop foot case related to hyperthyroidism of the ankle joint resulting in the relaxation of the toes during walking. This condition requires treatment using an ankle-foot orthosis. Traditional orthosis techniques lack precision and depend on the skill of the fabricator. This research aims to make a bias in ankle-foot orthosis design and analysis methods, where a complete methodology of numerical design and testing has been proposed using advanced engineering software. A numerical model of the patient's foot was generated and used to design an ankle-foot orthosis model using SolidWorks. The designed model was mechanically analyzed by the finite element method using ANSYS Workbench 16.1 under different static and dynamic loading conditions. The ankle-foot orthosis model was numerically designed and analyzed before the manufacturing process. This is believed to reduce time and material loss and foster the use of numerical models in biomedical applications. This study suggests focusing on the design and analysis of orthoses according to the patient's measurements. This is expected to increase the comfort and raise the level of treatment. Numerical design methods also enable precise manufacturing using computerized devices such as three-dimensional printers.
Faculty of Biomedical Engineering Al Andalus University for Medical Sciences Tartous Syria
Faculty of Mechanical Engineering Czech Technical University Prague Prague Czech Republic
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc20028213
- 003
- CZ-PrNML
- 005
- 20210114153235.0
- 007
- ta
- 008
- 210105s2020 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1177/0391398819890348 $2 doi
- 035 __
- $a (PubMed)31782688
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Darwich, Ayham $u Faculty of Biomedical Engineering, Al-Andalus University for Medical Sciences, Tartous, Syria. Faculty of Technical Engineering, University of Tartous, Tartous, Syria.
- 245 10
- $a Ankle-foot orthosis design between the tradition and the computerized perspectives / $c A. Darwich, H. Nazha, A. Sliman, W. Abbas,
- 520 9_
- $a This study focuses on the drop foot case related to hyperthyroidism of the ankle joint resulting in the relaxation of the toes during walking. This condition requires treatment using an ankle-foot orthosis. Traditional orthosis techniques lack precision and depend on the skill of the fabricator. This research aims to make a bias in ankle-foot orthosis design and analysis methods, where a complete methodology of numerical design and testing has been proposed using advanced engineering software. A numerical model of the patient's foot was generated and used to design an ankle-foot orthosis model using SolidWorks. The designed model was mechanically analyzed by the finite element method using ANSYS Workbench 16.1 under different static and dynamic loading conditions. The ankle-foot orthosis model was numerically designed and analyzed before the manufacturing process. This is believed to reduce time and material loss and foster the use of numerical models in biomedical applications. This study suggests focusing on the design and analysis of orthoses according to the patient's measurements. This is expected to increase the comfort and raise the level of treatment. Numerical design methods also enable precise manufacturing using computerized devices such as three-dimensional printers.
- 650 _2
- $a hlezenní kloub $x fyziologie $7 D000843
- 650 _2
- $a biomechanika $7 D001696
- 650 _2
- $a design s pomocí počítače $7 D017076
- 650 _2
- $a design vybavení $x metody $7 D004867
- 650 _2
- $a analýza metodou konečných prvků $7 D020342
- 650 12
- $a ortézy nohy (od hlezna dolů) $7 D061826
- 650 12
- $a neurologické poruchy chůze $x etiologie $x patofyziologie $x terapie $7 D020233
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a chůze $x fyziologie $7 D016138
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Nazha, Hasan $u Faculty of Biomedical Engineering, Al-Andalus University for Medical Sciences, Tartous, Syria. Faculty of Technical Engineering, University of Tartous, Tartous, Syria.
- 700 1_
- $a Sliman, Aleen $u Faculty of Biomedical Engineering, Al-Andalus University for Medical Sciences, Tartous, Syria.
- 700 1_
- $a Abbas, William $u Faculty of Mechanical Engineering, Czech Technical University in Prague, Prague, Czech Republic.
- 773 0_
- $w MED00002289 $t The International journal of artificial organs $x 1724-6040 $g Roč. 43, č. 5 (2020), s. 354-361
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/31782688 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y a $z 0
- 990 __
- $a 20210105 $b ABA008
- 991 __
- $a 20210114153232 $b ABA008
- 999 __
- $a ok $b bmc $g 1608548 $s 1119393
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $b 43 $c 5 $d 354-361 $e 20191129 $i 1724-6040 $m The International Journal of Artificial Organs $n Int. J. Artif. Organs (Testo stamp.) $x MED00002289
- LZP __
- $a Pubmed-20210105