-
Je něco špatně v tomto záznamu ?
Hybrid and Model-Based Iterative Reconstruction Influences the Volumetry of Visceral and Subcutaneous Adipose Tissue on Ultra-Low-Dose CT
L. Lambert, M. Novak, M. Siklova, E. Krauzova, V. Stich, A. Burgetova
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články, práce podpořená grantem
PubMed
32929884
DOI
10.1002/oby.22945
Knihovny.cz E-zdroje
- MeSH
- algoritmy MeSH
- dospělí MeSH
- lidé MeSH
- počítačová rentgenová tomografie metody MeSH
- podkožní tuk diagnostické zobrazování MeSH
- studie případů a kontrol MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mužské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
OBJECTIVE: The aim of this study was to compare three different reconstruction algorithms for the volumetry of the visceral adipose tissue (VAT) and subcutaneous adipose tissue (SAT) on ultra-low-dose computed tomography (CT) images. METHODS: Thirty-seven male patients underwent ultra-low-dose CT at the level of the fourth lumbar vertebra (22.5 mm in z-axis). The acquisitions were reconstructed in 5-mm slices with 50% overlap using filtered back projection (FBP), hybrid iterative reconstruction (HIR), and iterative model-based reconstruction (IMR) techniques. The volume of VAT and SAT was measured using an interactive seed-growing segmentation and by thresholding (-30 to -190 HU). RESULTS: The volume of SAT measured by the interactive method was smaller in FBP compared with both HIR (P = 0.0011) and IMR (P = 0.0034), and the volume of VAT was greater in IMR compared with HIR (P = 0.0253) or FBP (P = 0.0065). Using the thresholding method, IMR volumes of VAT were greater compared with HIR (P < 0.0001), and volumes of SAT were greater compared with both HIR and FBP (both P ≤ 0.0001). The VAT to SAT ratio was greater in IMR compared with HIR or FBP (both P < 0.0001). CONCLUSIONS: There are significant differences among FBP, HIR, and IMR in the volumetry of SAT and VAT, their ratios, and attenuation measured on ultra-low-dose images.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21011957
- 003
- CZ-PrNML
- 005
- 20230110093447.0
- 007
- ta
- 008
- 210420s2020 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1002/oby.22945 $2 doi
- 035 __
- $a (PubMed)32929884
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Lambert, Lukas $u Department of Radiology, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic
- 245 10
- $a Hybrid and Model-Based Iterative Reconstruction Influences the Volumetry of Visceral and Subcutaneous Adipose Tissue on Ultra-Low-Dose CT / $c L. Lambert, M. Novak, M. Siklova, E. Krauzova, V. Stich, A. Burgetova
- 520 9_
- $a OBJECTIVE: The aim of this study was to compare three different reconstruction algorithms for the volumetry of the visceral adipose tissue (VAT) and subcutaneous adipose tissue (SAT) on ultra-low-dose computed tomography (CT) images. METHODS: Thirty-seven male patients underwent ultra-low-dose CT at the level of the fourth lumbar vertebra (22.5 mm in z-axis). The acquisitions were reconstructed in 5-mm slices with 50% overlap using filtered back projection (FBP), hybrid iterative reconstruction (HIR), and iterative model-based reconstruction (IMR) techniques. The volume of VAT and SAT was measured using an interactive seed-growing segmentation and by thresholding (-30 to -190 HU). RESULTS: The volume of SAT measured by the interactive method was smaller in FBP compared with both HIR (P = 0.0011) and IMR (P = 0.0034), and the volume of VAT was greater in IMR compared with HIR (P = 0.0253) or FBP (P = 0.0065). Using the thresholding method, IMR volumes of VAT were greater compared with HIR (P < 0.0001), and volumes of SAT were greater compared with both HIR and FBP (both P ≤ 0.0001). The VAT to SAT ratio was greater in IMR compared with HIR or FBP (both P < 0.0001). CONCLUSIONS: There are significant differences among FBP, HIR, and IMR in the volumetry of SAT and VAT, their ratios, and attenuation measured on ultra-low-dose images.
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a algoritmy $7 D000465
- 650 _2
- $a studie případů a kontrol $7 D016022
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a podkožní tuk $x diagnostické zobrazování $7 D050151
- 650 _2
- $a počítačová rentgenová tomografie $x metody $7 D014057
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Novák, Matěj $u Department of Radiology, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic $7 xx0237560
- 700 1_
- $a Siklova, Michaela $u Department of Pathophysiology, Third Faculty of Medicine, Charles University, Prague, Czech Republic
- 700 1_
- $a Krauzova, Eva $u Department of Pathophysiology, Third Faculty of Medicine, Charles University, Prague, Czech Republic
- 700 1_
- $a Stich, Vladimir $u Department of Pathophysiology, Third Faculty of Medicine, Charles University, Prague, Czech Republic
- 700 1_
- $a Burgetova, Andrea $u Department of Radiology, First Faculty of Medicine, Charles University and General University Hospital in Prague, Prague, Czech Republic
- 773 0_
- $w MED00150944 $t Obesity $x 1930-739X $g Roč. 28, č. 11 (2020), s. 2083-2089
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/32929884 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20210420 $b ABA008
- 991 __
- $a 20230110093443 $b ABA008
- 999 __
- $a ok $b bmc $g 1650353 $s 1132336
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2020 $b 28 $c 11 $d 2083-2089 $e 20200914 $i 1930-739X $m Obesity $n Obesity (Silver Spring) $x MED00150944
- LZP __
- $a Pubmed-20210420