Automated seizure detection using wearable devices: A clinical practice guideline of the International League Against Epilepsy and the International Federation of Clinical Neurophysiology
S. Beniczky, S. Wiebe, J. Jeppesen, WO. Tatum, M. Brazdil, Y. Wang, ST. Herman, P. Ryvlin
Language English Country United States
Document type Journal Article, Practice Guideline
NLK
Free Medical Journals
from 1997 to 1 year ago
Wiley Free Content
from 1997 to 4 years ago
PubMed
33666944
DOI
10.1111/epi.16818
Knihovny.cz E-resources
- MeSH
- Monitoring, Ambulatory instrumentation methods standards MeSH
- Child MeSH
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Adolescent MeSH
- Young Adult MeSH
- Wearable Electronic Devices * standards MeSH
- Child, Preschool MeSH
- Aged MeSH
- Seizures diagnosis physiopathology MeSH
- Check Tag
- Child MeSH
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Adolescent MeSH
- Young Adult MeSH
- Child, Preschool MeSH
- Aged MeSH
- Publication type
- Journal Article MeSH
- Practice Guideline MeSH
The objective of this clinical practice guideline (CPG) is to provide recommendations for healthcare personnel working with patients with epilepsy on the use of wearable devices for automated seizure detection in patients with epilepsy, in outpatient, ambulatory settings. The Working Group of the International League Against Epilepsy (ILAE) and the International Federation of Clinical Neurophysiology (IFCN) developed the CPG according to the methodology proposed by the ILAE Epilepsy Guidelines Working Group. We reviewed the published evidence using The Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) statement and evaluated the evidence and formulated the recommendations following the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system. We found high level of evidence for the accuracy of automated detection of generalized tonic-clonic seizures (GTCS) and focal-to-bilateral tonic-clonic seizures (FBTCS) and recommend the use of wearable automated seizure detection devices for selected patients when accurate detection of GTCS and FBTCS is recommended as a clinical adjunct. We also found a moderate level of evidence for seizure types without GTCS or FBTCS. However, it was uncertain whether the detected alarms resulted in meaningful clinical outcomes for the patients. We recommend using clinically validated devices for automated detection of GTCS and FBTCS, especially in unsupervised patients, where alarms can result in rapid intervention (weak/conditional recommendation). At present, we do not recommend clinical use of the currently available devices for other seizure types (weak/conditional recommendation). Further research and development are needed to improve the performance of automated seizure detection and to document their accuracy and clinical utility.
Department of Clinical Medicine Aarhus University Aarhus C Denmark
Department of Clinical Neurophysiology Aarhus University Hospital Aarhus C Denmark
Department of Neurology Barrow Neurological Institute Phoenix AZ USA
Department of Neurology Mayo Clinic Jacksonville Florida USA
Department of Neurology Xuanwu Hospital Capital Medical University Beijing China
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc21026005
- 003
- CZ-PrNML
- 005
- 20211026133305.0
- 007
- ta
- 008
- 211013s2021 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1111/epi.16818 $2 doi
- 035 __
- $a (PubMed)33666944
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Beniczky, Sándor $u Department of Clinical Neurophysiology, Danish Epilepsy Centre and Aarhus University Hospital, Dianalund, Denmark $u Department of Clinical Medicine, Aarhus University, Aarhus C, Denmark
- 245 10
- $a Automated seizure detection using wearable devices: A clinical practice guideline of the International League Against Epilepsy and the International Federation of Clinical Neurophysiology / $c S. Beniczky, S. Wiebe, J. Jeppesen, WO. Tatum, M. Brazdil, Y. Wang, ST. Herman, P. Ryvlin
- 520 9_
- $a The objective of this clinical practice guideline (CPG) is to provide recommendations for healthcare personnel working with patients with epilepsy on the use of wearable devices for automated seizure detection in patients with epilepsy, in outpatient, ambulatory settings. The Working Group of the International League Against Epilepsy (ILAE) and the International Federation of Clinical Neurophysiology (IFCN) developed the CPG according to the methodology proposed by the ILAE Epilepsy Guidelines Working Group. We reviewed the published evidence using The Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) statement and evaluated the evidence and formulated the recommendations following the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system. We found high level of evidence for the accuracy of automated detection of generalized tonic-clonic seizures (GTCS) and focal-to-bilateral tonic-clonic seizures (FBTCS) and recommend the use of wearable automated seizure detection devices for selected patients when accurate detection of GTCS and FBTCS is recommended as a clinical adjunct. We also found a moderate level of evidence for seizure types without GTCS or FBTCS. However, it was uncertain whether the detected alarms resulted in meaningful clinical outcomes for the patients. We recommend using clinically validated devices for automated detection of GTCS and FBTCS, especially in unsupervised patients, where alarms can result in rapid intervention (weak/conditional recommendation). At present, we do not recommend clinical use of the currently available devices for other seizure types (weak/conditional recommendation). Further research and development are needed to improve the performance of automated seizure detection and to document their accuracy and clinical utility.
- 650 _2
- $a mladiství $7 D000293
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a dítě $7 D002648
- 650 _2
- $a předškolní dítě $7 D002675
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a ambulantní monitorování $x přístrojové vybavení $x metody $x normy $7 D018670
- 650 _2
- $a záchvaty $x diagnóza $x patofyziologie $7 D012640
- 650 12
- $a nositelná elektronika $x normy $7 D000076251
- 650 _2
- $a mladý dospělý $7 D055815
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a směrnice pro lékařskou praxi $7 D017065
- 700 1_
- $a Wiebe, Samuel $u Department of Clinical Neurosciences and Clinical Research Unit, Cumming School of Medicine, University of Calgary, Calgary, Canada
- 700 1_
- $a Jeppesen, Jesper $u Department of Clinical Neurophysiology, Aarhus University Hospital, Aarhus C, Denmark
- 700 1_
- $a Tatum, William O $u Department of Neurology, Mayo Clinic, Jacksonville, Florida, USA
- 700 1_
- $a Brazdil, Milan $u Brno Epilepsy Center, Department of Neurology, St. Anne's University Hospital and Medical Faculty of Masaryk University, Brno, Czech Republic $u Behavioral and Social Neuroscience Research Group, Central European Institute of Technology, Masaryk University, Brno, Czech Republic
- 700 1_
- $a Wang, Yuping $u Department of Neurology, Xuanwu Hospital, Capital Medical University, Beijing, China
- 700 1_
- $a Herman, Susan T $u Department of Neurology, Barrow Neurological Institute, Phoenix, AZ, USA
- 700 1_
- $a Ryvlin, Philippe $u Department of Clinical Neurosciences, Centre Hospitalier Universitaire Vaudois, Université de Lausanne, Lausanne, Switzerland
- 773 0_
- $w MED00001567 $t Epilepsia $x 1528-1167 $g Roč. 62, č. 3 (2021), s. 632-646
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/33666944 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20211013 $b ABA008
- 991 __
- $a 20211026133311 $b ABA008
- 999 __
- $a ok $b bmc $g 1714882 $s 1146512
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2021 $b 62 $c 3 $d 632-646 $e - $i 1528-1167 $m Epilepsia $n Epilepsia $x MED00001567
- LZP __
- $a Pubmed-20211013