Biosensors as Nano-Analytical Tools for COVID-19 Detection

A. Pradhan, P. Lahare, P. Sinha, N. Singh, B. Gupta, K. Kuca, KK. Ghosh, O. Krejcar

. 2021 ; 21 (23) : . [pub] 20211124

Jazyk angličtina Země Švýcarsko

Typ dokumentu časopisecké články, přehledy

Perzistentní odkaz   https://www.medvik.cz/link/bmc22003171

Selective, sensitive and affordable techniques to detect disease and underlying health issues have been developed recently. Biosensors as nanoanalytical tools have taken a front seat in this context. Nanotechnology-enabled progress in the health sector has aided in disease and pandemic management at a very early stage efficiently. This report reflects the state-of-the-art of nanobiosensor-based virus detection technology in terms of their detection methods, targets, limits of detection, range, sensitivity, assay time, etc. The article effectively summarizes the challenges with traditional technologies and newly emerging biosensors, including the nanotechnology-based detection kit for COVID-19; optically enhanced technology; and electrochemical, smart and wearable enabled nanobiosensors. The less explored but crucial piezoelectric nanobiosensor and the reverse transcription-loop mediated isothermal amplification (RT-LAMP)-based biosensor are also discussed here. The article could be of significance to researchers and doctors dedicated to developing potent, versatile biosensors for the rapid identification of COVID-19. This kind of report is needed for selecting suitable treatments and to avert epidemics.

000      
00000naa a2200000 a 4500
001      
bmc22003171
003      
CZ-PrNML
005      
20220127150616.0
007      
ta
008      
220113s2021 sz f 000 0|eng||
009      
AR
024    7_
$a 10.3390/s21237823 $2 doi
035    __
$a (PubMed)34883826
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a sz
100    1_
$a Pradhan, Anchal $u Center for Basic Sciences, Department of Chemistry, Pt. Ravishankar Shukla University, Raipur 492010, India
245    10
$a Biosensors as Nano-Analytical Tools for COVID-19 Detection / $c A. Pradhan, P. Lahare, P. Sinha, N. Singh, B. Gupta, K. Kuca, KK. Ghosh, O. Krejcar
520    9_
$a Selective, sensitive and affordable techniques to detect disease and underlying health issues have been developed recently. Biosensors as nanoanalytical tools have taken a front seat in this context. Nanotechnology-enabled progress in the health sector has aided in disease and pandemic management at a very early stage efficiently. This report reflects the state-of-the-art of nanobiosensor-based virus detection technology in terms of their detection methods, targets, limits of detection, range, sensitivity, assay time, etc. The article effectively summarizes the challenges with traditional technologies and newly emerging biosensors, including the nanotechnology-based detection kit for COVID-19; optically enhanced technology; and electrochemical, smart and wearable enabled nanobiosensors. The less explored but crucial piezoelectric nanobiosensor and the reverse transcription-loop mediated isothermal amplification (RT-LAMP)-based biosensor are also discussed here. The article could be of significance to researchers and doctors dedicated to developing potent, versatile biosensors for the rapid identification of COVID-19. This kind of report is needed for selecting suitable treatments and to avert epidemics.
650    12
$a biosenzitivní techniky $7 D015374
650    12
$a COVID-19 $7 D000086382
650    _2
$a lidé $7 D006801
650    _2
$a nanotechnologie $7 D036103
650    _2
$a techniky amplifikace nukleových kyselin $7 D021141
650    _2
$a pandemie $7 D058873
650    _2
$a SARS-CoV-2 $7 D000086402
650    _2
$a senzitivita a specificita $7 D012680
655    _2
$a časopisecké články $7 D016428
655    _2
$a přehledy $7 D016454
700    1_
$a Lahare, Preeti $u Center for Basic Sciences, Department of Chemistry, Pt. Ravishankar Shukla University, Raipur 492010, India
700    1_
$a Sinha, Priyank $u Center for Basic Sciences, Department of Chemistry, Pt. Ravishankar Shukla University, Raipur 492010, India
700    1_
$a Singh, Namrata $u Ramrao Adik Institute of Technology, DY Patil University, Nerul, Navi Mumbai 400706, India $u Department of Chemistry, Faculty of Science, University of Hradec Kralove, Rokitanskeho 62, 50003 Hradec Kralove, Czech Republic
700    1_
$a Gupta, Bhanushree $u Center for Basic Sciences, Department of Chemistry, Pt. Ravishankar Shukla University, Raipur 492010, India
700    1_
$a Kuca, Kamil $u Department of Chemistry, Faculty of Science, University of Hradec Kralove, Rokitanskeho 62, 50003 Hradec Kralove, Czech Republic $u Biomedical Research Center, University Hospital, Sokolska 581, 50005 Hradec Kralove, Czech Republic
700    1_
$a Ghosh, Kallol K $u Center for Basic Sciences, Department of Chemistry, Pt. Ravishankar Shukla University, Raipur 492010, India $u School of Studies in Chemistry, Pt. Ravishankar Shukla University, Raipur 492010, India
700    1_
$a Krejcar, Ondrej $u Center for Basic and Applied Research, Faculty of Informatics and Management, University of Hradec Kralove, Rokitanskeho 62, 50003 Hradec Kralove, Czech Republic
773    0_
$w MED00008309 $t Sensors (Basel, Switzerland) $x 1424-8220 $g Roč. 21, č. 23 (2021)
856    41
$u https://pubmed.ncbi.nlm.nih.gov/34883826 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20220113 $b ABA008
991    __
$a 20220127150612 $b ABA008
999    __
$a ok $b bmc $g 1750820 $s 1154320
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 21 $c 23 $e 20211124 $i 1424-8220 $m Sensors $n Sensors Basel $x MED00008309
LZP    __
$a Pubmed-20220113

Najít záznam

Citační ukazatele

Nahrávání dat...

Možnosti archivace

Nahrávání dat...