-
Something wrong with this record ?
Feasibility Evaluation of Metamaterial Microwave Sensors for Non-Invasive Blood Glucose Monitoring
L. Malena, O. Fiser, PR. Stauffer, T. Drizdal, J. Vrba, D. Vrba
Language English Country Switzerland
Document type Journal Article
Grant support
LTC19031; SGS21/179/OHK4/3T/17
Ministry of Education, Youth and Sports of the Czech Republic; Student Grant Competition of CTU
NLK
Directory of Open Access Journals
from 2001
PubMed Central
from 2003
Europe PubMed Central
from 2003
ProQuest Central
from 2001-01-01
Open Access Digital Library
from 2001-01-01
Open Access Digital Library
from 2003-01-01
Health & Medicine (ProQuest)
from 2001-01-01
ROAD: Directory of Open Access Scholarly Resources
from 2001
PubMed
34696084
DOI
10.3390/s21206871
Knihovny.cz E-resources
- MeSH
- Blood Glucose * MeSH
- Humans MeSH
- Microwaves MeSH
- Monitoring, Physiologic MeSH
- Blood Glucose Self-Monitoring * MeSH
- Feasibility Studies MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
The use of microwave technology is currently under investigation for non-invasive estimation of glycemia in patients with diabetes. Due to their construction, metamaterial (MTM)-based sensors have the potential to provide higher sensitivity of the phase shift of the S21 parameter (∠S21) to changes in glucose concentration compared to standard microstrip transmission line (MSTL)-based sensors. In this study, a MSTL sensor and three MTM sensors with 5, 7, and 9 MTM unit cells are exposed to liquid phantoms with different dielectric properties mimicking a change in blood glucose concentration from 0 to 14 mmol/L. Numerical models were created for the individual experiments, and the calculated S-parameters show good agreement with experimental results, expressed by the maximum relative error of 8.89% and 0.96% at a frequency of 1.99 GHz for MSTL and MTM sensor with nine unit cells, respectively. MTM sensors with an increasing number of cells show higher sensitivity of 0.62° per mmol/L and unit cell to blood glucose concentration as measured by changes in ∠S21. In accordance with the numerical simulations, the MTM sensor with nine unit cells showed the highest sensitivity of the sensors proposed by us, with an average of 3.66° per mmol/L at a frequency of 1.99 GHz, compared to only 0.48° per mmol/L for the MSTL sensor. The multi-cell MTM sensor has the potential to proceed with evaluation of human blood samples.
Department of Radiation Oncology Thomas Jefferson University Philadelphia PA 19107 USA
Faculty of Biomedical Engineering Czech Technical University Prague 160 00 Prague Czech Republic
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22003454
- 003
- CZ-PrNML
- 005
- 20220127150221.0
- 007
- ta
- 008
- 220113s2021 sz f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.3390/s21206871 $2 doi
- 035 __
- $a (PubMed)34696084
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a sz
- 100 1_
- $a Malena, Lukas $u Faculty of Biomedical Engineering, Czech Technical University in Prague, 160 00 Prague, Czech Republic
- 245 10
- $a Feasibility Evaluation of Metamaterial Microwave Sensors for Non-Invasive Blood Glucose Monitoring / $c L. Malena, O. Fiser, PR. Stauffer, T. Drizdal, J. Vrba, D. Vrba
- 520 9_
- $a The use of microwave technology is currently under investigation for non-invasive estimation of glycemia in patients with diabetes. Due to their construction, metamaterial (MTM)-based sensors have the potential to provide higher sensitivity of the phase shift of the S21 parameter (∠S21) to changes in glucose concentration compared to standard microstrip transmission line (MSTL)-based sensors. In this study, a MSTL sensor and three MTM sensors with 5, 7, and 9 MTM unit cells are exposed to liquid phantoms with different dielectric properties mimicking a change in blood glucose concentration from 0 to 14 mmol/L. Numerical models were created for the individual experiments, and the calculated S-parameters show good agreement with experimental results, expressed by the maximum relative error of 8.89% and 0.96% at a frequency of 1.99 GHz for MSTL and MTM sensor with nine unit cells, respectively. MTM sensors with an increasing number of cells show higher sensitivity of 0.62° per mmol/L and unit cell to blood glucose concentration as measured by changes in ∠S21. In accordance with the numerical simulations, the MTM sensor with nine unit cells showed the highest sensitivity of the sensors proposed by us, with an average of 3.66° per mmol/L at a frequency of 1.99 GHz, compared to only 0.48° per mmol/L for the MSTL sensor. The multi-cell MTM sensor has the potential to proceed with evaluation of human blood samples.
- 650 12
- $a krevní glukóza $7 D001786
- 650 12
- $a selfmonitoring glykemie $7 D015190
- 650 _2
- $a studie proveditelnosti $7 D005240
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mikrovlny $7 D008872
- 650 _2
- $a monitorování fyziologických funkcí $7 D008991
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Fiser, Ondrej $u Faculty of Biomedical Engineering, Czech Technical University in Prague, 160 00 Prague, Czech Republic
- 700 1_
- $a Stauffer, Paul R $u Department of Radiation Oncology, Thomas Jefferson University, Philadelphia, PA 19107, USA
- 700 1_
- $a Drizdal, Tomas $u Faculty of Biomedical Engineering, Czech Technical University in Prague, 160 00 Prague, Czech Republic
- 700 1_
- $a Vrba, Jan $u Faculty of Biomedical Engineering, Czech Technical University in Prague, 160 00 Prague, Czech Republic
- 700 1_
- $a Vrba, David $u Faculty of Biomedical Engineering, Czech Technical University in Prague, 160 00 Prague, Czech Republic
- 773 0_
- $w MED00008309 $t Sensors (Basel, Switzerland) $x 1424-8220 $g Roč. 21, č. 20 (2021)
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/34696084 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20220113 $b ABA008
- 991 __
- $a 20220127150217 $b ABA008
- 999 __
- $a ok $b bmc $g 1751033 $s 1154603
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2021 $b 21 $c 20 $e 20211016 $i 1424-8220 $m Sensors $n Sensors Basel $x MED00008309
- GRA __
- $a LTC19031; SGS21/179/OHK4/3T/17 $p Ministry of Education, Youth and Sports of the Czech Republic; Student Grant Competition of CTU
- LZP __
- $a Pubmed-20220113