Je něco špatně v tomto záznamu ?
In Vivo Measurements of Middle Ear Temperature During Transcanal Endoscopic Ear Surgery
P. Beláková, R. Salzman, M. Hyravý, J. Heřman
Jazyk angličtina Země Spojené státy americké
Typ dokumentu časopisecké články, práce podpořená grantem
- MeSH
- endoskopie MeSH
- kohortové studie MeSH
- lidé MeSH
- otologické chirurgické výkony * MeSH
- střední ucho chirurgie MeSH
- tělesná teplota * MeSH
- teplota MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
OBJECTIVE: The light emitted from the endoscope during transcanal endoscopic ear surgery (TEES) heats the intratympanic space. This heat may potentially be dangerous to nearby important structures, as documented by in vitro and by animal and cadaveric studies. The aim of our work was to monitor middle ear temperatures during TEES in vivo. STUDY DESIGN: Cohort study. SETTING: Tertiary referral hospital. PATIENTS: Four patients (15-69 yrs old) underwent transcanal endoscopic tympanoplasties for chronic perforation or retraction. INTERVENTION: After elevating the tympanomeatal flap, a thermocouple was placed in the middle ear to measure the heat generated by a 30° Hopkins rod telescope (11 cm long, 2.7 mm wide) and fiberoptic light emitting diode light source. MAIN OUTCOME MEASURES: Middle ear temperature in the retrotympanum was monitored under these conditions: at 50 and 100% light intensity, after removing and wiping the endoscope tip, during suctioning and following middle ear irrigation. RESULTS: Maximum middle ear temperature ranged from 36.26-37.30°C. Pulling out and wiping the endoscope caused no change or minimal decrease of 0.16°C. Middle ear irrigation caused a temperature drop of 2.05°C to 5.11°C. Suctioning was associated with a drop from 0.24°C to 3.91°C that was dependent on the depth of the endoscopic tip. CONCLUSION: Middle ear temperatures during TEES using a Hopkins rod telescope and light-emitting diode light source reach values corresponding to physiological body temperature, and do not reach dangerous levels.
Citace poskytuje Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22003848
- 003
- CZ-PrNML
- 005
- 20220127145809.0
- 007
- ta
- 008
- 220113s2021 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1097/MAO.0000000000003142 $2 doi
- 035 __
- $a (PubMed)33741819
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Beláková, Petra $u Department of Otorhinolaryngology and Head and Neck Surgery, Faculty Hospital and Faculty of Medicine and Dentistry, Palacky University Olomouc, Olomouc, Czech Republic
- 245 10
- $a In Vivo Measurements of Middle Ear Temperature During Transcanal Endoscopic Ear Surgery / $c P. Beláková, R. Salzman, M. Hyravý, J. Heřman
- 520 9_
- $a OBJECTIVE: The light emitted from the endoscope during transcanal endoscopic ear surgery (TEES) heats the intratympanic space. This heat may potentially be dangerous to nearby important structures, as documented by in vitro and by animal and cadaveric studies. The aim of our work was to monitor middle ear temperatures during TEES in vivo. STUDY DESIGN: Cohort study. SETTING: Tertiary referral hospital. PATIENTS: Four patients (15-69 yrs old) underwent transcanal endoscopic tympanoplasties for chronic perforation or retraction. INTERVENTION: After elevating the tympanomeatal flap, a thermocouple was placed in the middle ear to measure the heat generated by a 30° Hopkins rod telescope (11 cm long, 2.7 mm wide) and fiberoptic light emitting diode light source. MAIN OUTCOME MEASURES: Middle ear temperature in the retrotympanum was monitored under these conditions: at 50 and 100% light intensity, after removing and wiping the endoscope tip, during suctioning and following middle ear irrigation. RESULTS: Maximum middle ear temperature ranged from 36.26-37.30°C. Pulling out and wiping the endoscope caused no change or minimal decrease of 0.16°C. Middle ear irrigation caused a temperature drop of 2.05°C to 5.11°C. Suctioning was associated with a drop from 0.24°C to 3.91°C that was dependent on the depth of the endoscopic tip. CONCLUSION: Middle ear temperatures during TEES using a Hopkins rod telescope and light-emitting diode light source reach values corresponding to physiological body temperature, and do not reach dangerous levels.
- 650 12
- $a tělesná teplota $7 D001831
- 650 _2
- $a kohortové studie $7 D015331
- 650 _2
- $a střední ucho $x chirurgie $7 D004432
- 650 _2
- $a endoskopie $7 D004724
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a otologické chirurgické výkony $7 D013506
- 650 _2
- $a teplota $7 D013696
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Salzman, Richard
- 700 1_
- $a Hyravý, Martin
- 700 1_
- $a Heřman, Jan
- 773 0_
- $w MED00006516 $t Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology $x 1537-4505 $g Roč. 42, č. 8 (2021), s. e1037-e1041
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/33741819 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20220113 $b ABA008
- 991 __
- $a 20220127145805 $b ABA008
- 999 __
- $a ok $b bmc $g 1751345 $s 1154997
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2021 $b 42 $c 8 $d e1037-e1041 $e 20210901 $i 1537-4505 $m Otology & neurotology $n Otol Neurotol $x MED00006516
- LZP __
- $a Pubmed-20220113