OBJECTIVE: The light emitted from the endoscope during transcanal endoscopic ear surgery (TEES) heats the intratympanic space. This heat may potentially be dangerous to nearby important structures, as documented by in vitro and by animal and cadaveric studies. The aim of our work was to monitor middle ear temperatures during TEES in vivo. STUDY DESIGN: Cohort study. SETTING: Tertiary referral hospital. PATIENTS: Four patients (15-69 yrs old) underwent transcanal endoscopic tympanoplasties for chronic perforation or retraction. INTERVENTION: After elevating the tympanomeatal flap, a thermocouple was placed in the middle ear to measure the heat generated by a 30° Hopkins rod telescope (11 cm long, 2.7 mm wide) and fiberoptic light emitting diode light source. MAIN OUTCOME MEASURES: Middle ear temperature in the retrotympanum was monitored under these conditions: at 50 and 100% light intensity, after removing and wiping the endoscope tip, during suctioning and following middle ear irrigation. RESULTS: Maximum middle ear temperature ranged from 36.26-37.30°C. Pulling out and wiping the endoscope caused no change or minimal decrease of 0.16°C. Middle ear irrigation caused a temperature drop of 2.05°C to 5.11°C. Suctioning was associated with a drop from 0.24°C to 3.91°C that was dependent on the depth of the endoscopic tip. CONCLUSION: Middle ear temperatures during TEES using a Hopkins rod telescope and light-emitting diode light source reach values corresponding to physiological body temperature, and do not reach dangerous levels.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22003848
003      
CZ-PrNML
005      
20220127145809.0
007      
ta
008      
220113s2021 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1097/MAO.0000000000003142 $2 doi
035    __
$a (PubMed)33741819
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Beláková, Petra $u Department of Otorhinolaryngology and Head and Neck Surgery, Faculty Hospital and Faculty of Medicine and Dentistry, Palacky University Olomouc, Olomouc, Czech Republic
245    10
$a In Vivo Measurements of Middle Ear Temperature During Transcanal Endoscopic Ear Surgery / $c P. Beláková, R. Salzman, M. Hyravý, J. Heřman
520    9_
$a OBJECTIVE: The light emitted from the endoscope during transcanal endoscopic ear surgery (TEES) heats the intratympanic space. This heat may potentially be dangerous to nearby important structures, as documented by in vitro and by animal and cadaveric studies. The aim of our work was to monitor middle ear temperatures during TEES in vivo. STUDY DESIGN: Cohort study. SETTING: Tertiary referral hospital. PATIENTS: Four patients (15-69 yrs old) underwent transcanal endoscopic tympanoplasties for chronic perforation or retraction. INTERVENTION: After elevating the tympanomeatal flap, a thermocouple was placed in the middle ear to measure the heat generated by a 30° Hopkins rod telescope (11 cm long, 2.7 mm wide) and fiberoptic light emitting diode light source. MAIN OUTCOME MEASURES: Middle ear temperature in the retrotympanum was monitored under these conditions: at 50 and 100% light intensity, after removing and wiping the endoscope tip, during suctioning and following middle ear irrigation. RESULTS: Maximum middle ear temperature ranged from 36.26-37.30°C. Pulling out and wiping the endoscope caused no change or minimal decrease of 0.16°C. Middle ear irrigation caused a temperature drop of 2.05°C to 5.11°C. Suctioning was associated with a drop from 0.24°C to 3.91°C that was dependent on the depth of the endoscopic tip. CONCLUSION: Middle ear temperatures during TEES using a Hopkins rod telescope and light-emitting diode light source reach values corresponding to physiological body temperature, and do not reach dangerous levels.
650    12
$a tělesná teplota $7 D001831
650    _2
$a kohortové studie $7 D015331
650    _2
$a střední ucho $x chirurgie $7 D004432
650    _2
$a endoskopie $7 D004724
650    _2
$a lidé $7 D006801
650    12
$a otologické chirurgické výkony $7 D013506
650    _2
$a teplota $7 D013696
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Salzman, Richard
700    1_
$a Hyravý, Martin
700    1_
$a Heřman, Jan
773    0_
$w MED00006516 $t Otology & neurotology : official publication of the American Otological Society, American Neurotology Society [and] European Academy of Otology and Neurotology $x 1537-4505 $g Roč. 42, č. 8 (2021), s. e1037-e1041
856    41
$u https://pubmed.ncbi.nlm.nih.gov/33741819 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20220113 $b ABA008
991    __
$a 20220127145805 $b ABA008
999    __
$a ok $b bmc $g 1751345 $s 1154997
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 42 $c 8 $d e1037-e1041 $e 20210901 $i 1537-4505 $m Otology & neurotology $n Otol Neurotol $x MED00006516
LZP    __
$a Pubmed-20220113

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...