Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Application of capillary electrophoresis-nano-electrospray ionization-mass spectrometry for the determination of N-nitrosodimethylamine in pharmaceuticals

R. Řemínek, F. Foret, DS. Chung

. 2021 ; 42 (4) : 334-341. [pub] 20210114

Jazyk angličtina Země Německo

Typ dokumentu časopisecké články, práce podpořená grantem

Perzistentní odkaz   https://www.medvik.cz/link/bmc22004643

After a presence of highly hepatotoxic and potentially carcinogenic N-nitrosodimethylamine was detected in certain lots of sartan, ranitidine, metformin, and other pharmaceuticals, local regulatory authorities issued recalls of suspected products, and concerns of the pharmacotherapy safety were widely discussed. Since then, testing of a representative sample of each produced lot of these pharmaceuticals is required as a part of quality control processes. Hence, an interface-free CE-nanoESI system coupled with MS detection was employed for the development of a simple and economical method for quantitative detection of this contaminant in the valsartan drug substances and finished formulations used as model matrices. In this arrangement, a fused-silica capillary was used as both a separation column and a nanoESI emitter providing high ionization efficiency and sensitivity. The optimized procedure was found to have sufficient selectivity, linearity, accuracy, and precision. The established LOD and LOQ values were 0.3 and 1.0 ng/mL, respectively. The practical applicability of the method was tested by analyses of commercially available Valsacor® tablets. The results obtained prove that the developed procedure represents a promising alternative to currently available GC- and LC-based methods. Furthermore, after an adjustment of the separation conditions, the CE-nanoESI/MS system can be conceptually used for the determination of NDMA in other suspected pharmaceuticals.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22004643
003      
CZ-PrNML
005      
20220127145108.0
007      
ta
008      
220113s2021 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1002/elps.202000303 $2 doi
035    __
$a (PubMed)33368407
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Řemínek, Roman $u Institute of Analytical Chemistry of the Czech Academy of Sciences, v. v. i., Brno, Czech Republic
245    10
$a Application of capillary electrophoresis-nano-electrospray ionization-mass spectrometry for the determination of N-nitrosodimethylamine in pharmaceuticals / $c R. Řemínek, F. Foret, DS. Chung
520    9_
$a After a presence of highly hepatotoxic and potentially carcinogenic N-nitrosodimethylamine was detected in certain lots of sartan, ranitidine, metformin, and other pharmaceuticals, local regulatory authorities issued recalls of suspected products, and concerns of the pharmacotherapy safety were widely discussed. Since then, testing of a representative sample of each produced lot of these pharmaceuticals is required as a part of quality control processes. Hence, an interface-free CE-nanoESI system coupled with MS detection was employed for the development of a simple and economical method for quantitative detection of this contaminant in the valsartan drug substances and finished formulations used as model matrices. In this arrangement, a fused-silica capillary was used as both a separation column and a nanoESI emitter providing high ionization efficiency and sensitivity. The optimized procedure was found to have sufficient selectivity, linearity, accuracy, and precision. The established LOD and LOQ values were 0.3 and 1.0 ng/mL, respectively. The practical applicability of the method was tested by analyses of commercially available Valsacor® tablets. The results obtained prove that the developed procedure represents a promising alternative to currently available GC- and LC-based methods. Furthermore, after an adjustment of the separation conditions, the CE-nanoESI/MS system can be conceptually used for the determination of NDMA in other suspected pharmaceuticals.
650    _2
$a dimethylnitrosamin $x analýza $7 D004128
650    12
$a kontaminace léku $7 D004340
650    _2
$a elektroforéza kapilární $x metody $7 D019075
650    _2
$a lineární modely $7 D016014
650    _2
$a nanotechnologie $7 D036103
650    _2
$a reprodukovatelnost výsledků $7 D015203
650    _2
$a senzitivita a specificita $7 D012680
650    _2
$a hmotnostní spektrometrie s elektrosprejovou ionizací $x metody $7 D021241
650    _2
$a tablety $7 D013607
650    _2
$a valsartan $x chemie $7 D000068756
655    _2
$a časopisecké články $7 D016428
655    _2
$a práce podpořená grantem $7 D013485
700    1_
$a Foret, František $u Institute of Analytical Chemistry of the Czech Academy of Sciences, v. v. i., Brno, Czech Republic
700    1_
$a Chung, Doo Soo $u Department of Chemistry, Seoul National University, Seoul, Korea
773    0_
$w MED00001508 $t Electrophoresis $x 1522-2683 $g Roč. 42, č. 4 (2021), s. 334-341
856    41
$u https://pubmed.ncbi.nlm.nih.gov/33368407 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20220113 $b ABA008
991    __
$a 20220127145104 $b ABA008
999    __
$a ok $b bmc $g 1751951 $s 1155792
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2021 $b 42 $c 4 $d 334-341 $e 20210114 $i 1522-2683 $m Electrophoresis $n Electrophoresis $x MED00001508
LZP    __
$a Pubmed-20220113

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...