Detail
Článek
Článek online
FT
Medvik - BMČ
  • Je něco špatně v tomto záznamu ?

Multimodal combination of neuroimaging methods for localizing the epileptogenic zone in MR-negative epilepsy

P. Říha, I. Doležalová, R. Mareček, M. Lamoš, M. Bartoňová, M. Kojan, M. Mikl, M. Gajdoš, L. Vojtíšek, M. Bartoň, O. Strýček, M. Pail, M. Brázdil, I. Rektor

. 2022 ; 12 (1) : 15158. [pub] 20220907

Jazyk angličtina Země Anglie, Velká Británie

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc22024460

Grantová podpora
NU21-04-00254 Czech Health Research Council
LM2018129 Czech-BioImaging MEYS CR

The objective was to determine the optimal combination of multimodal imaging methods (IMs) for localizing the epileptogenic zone (EZ) in patients with MR-negative drug-resistant epilepsy. Data from 25 patients with MR-negative focal epilepsy (age 30 ± 10 years, 16M/9F) who underwent surgical resection of the EZ and from 110 healthy controls (age 31 ± 9 years; 56M/54F) were used to evaluate IMs based on 3T MRI, FDG-PET, HD-EEG, and SPECT. Patients with successful outcomes and/or positive histological findings were evaluated. From 38 IMs calculated per patient, 13 methods were selected by evaluating the mutual similarity of the methods and the accuracy of the EZ localization. The best results in postsurgical patients for EZ localization were found for ictal/ interictal SPECT (SISCOM), FDG-PET, arterial spin labeling (ASL), functional regional homogeneity (ReHo), gray matter volume (GMV), cortical thickness, HD electrical source imaging (ESI-HD), amplitude of low-frequency fluctuation (ALFF), diffusion tensor imaging, and kurtosis imaging. Combining IMs provides the method with the most accurate EZ identification in MR-negative epilepsy. The PET, SISCOM, and selected MRI-post-processing techniques are useful for EZ localization for surgical tailoring.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc22024460
003      
CZ-PrNML
005      
20250423101400.0
007      
ta
008      
221017s2022 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1038/s41598-022-19121-8 $2 doi
035    __
$a (PubMed)36071087
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Říha, Pavel $u First Department of Neurology, St. Anne's University Hospital and Faculty of Medicine, Masaryk University, Brno, Czech Republic $u Multimodal and Functional Neuroimaging Research Group, CEITEC-Central European Institute of Technology, Masaryk University, Brno, Czech Republic $1 https://orcid.org/http://orcid.org/0000000213222038
245    10
$a Multimodal combination of neuroimaging methods for localizing the epileptogenic zone in MR-negative epilepsy / $c P. Říha, I. Doležalová, R. Mareček, M. Lamoš, M. Bartoňová, M. Kojan, M. Mikl, M. Gajdoš, L. Vojtíšek, M. Bartoň, O. Strýček, M. Pail, M. Brázdil, I. Rektor
520    9_
$a The objective was to determine the optimal combination of multimodal imaging methods (IMs) for localizing the epileptogenic zone (EZ) in patients with MR-negative drug-resistant epilepsy. Data from 25 patients with MR-negative focal epilepsy (age 30 ± 10 years, 16M/9F) who underwent surgical resection of the EZ and from 110 healthy controls (age 31 ± 9 years; 56M/54F) were used to evaluate IMs based on 3T MRI, FDG-PET, HD-EEG, and SPECT. Patients with successful outcomes and/or positive histological findings were evaluated. From 38 IMs calculated per patient, 13 methods were selected by evaluating the mutual similarity of the methods and the accuracy of the EZ localization. The best results in postsurgical patients for EZ localization were found for ictal/ interictal SPECT (SISCOM), FDG-PET, arterial spin labeling (ASL), functional regional homogeneity (ReHo), gray matter volume (GMV), cortical thickness, HD electrical source imaging (ESI-HD), amplitude of low-frequency fluctuation (ALFF), diffusion tensor imaging, and kurtosis imaging. Combining IMs provides the method with the most accurate EZ identification in MR-negative epilepsy. The PET, SISCOM, and selected MRI-post-processing techniques are useful for EZ localization for surgical tailoring.
650    _2
$a dospělí $7 D000328
650    _2
$a zobrazování difuzních tenzorů $7 D056324
650    _2
$a elektroencefalografie $7 D004569
650    12
$a epilepsie $x diagnostické zobrazování $x chirurgie $7 D004827
650    12
$a fluorodeoxyglukosa F18 $7 D019788
650    _2
$a lidé $7 D006801
650    _2
$a magnetická rezonanční tomografie $x metody $7 D008279
650    _2
$a neurozobrazování $x metody $7 D059906
650    _2
$a mladý dospělý $7 D055815
655    _2
$a časopisecké články $7 D016428
700    1_
$a Doležalová, Irena $u First Department of Neurology, St. Anne's University Hospital and Faculty of Medicine, Masaryk University, Brno, Czech Republic $1 https://orcid.org/http://orcid.org/0000000231664817
700    1_
$a Mareček, Radek $u Multimodal and Functional Neuroimaging Research Group, CEITEC-Central European Institute of Technology, Masaryk University, Brno, Czech Republic $1 https://orcid.org/http://orcid.org/0000000183993455
700    1_
$a Lamoš, Martin $u Multimodal and Functional Neuroimaging Research Group, CEITEC-Central European Institute of Technology, Masaryk University, Brno, Czech Republic $1 https://orcid.org/http://orcid.org/0000000312764342
700    1_
$a Bartoňová, Michaela $u First Department of Neurology, St. Anne's University Hospital and Faculty of Medicine, Masaryk University, Brno, Czech Republic $u Multimodal and Functional Neuroimaging Research Group, CEITEC-Central European Institute of Technology, Masaryk University, Brno, Czech Republic $1 https://orcid.org/http://orcid.org/0000000306805646
700    1_
$a Kojan, Martin $u First Department of Neurology, St. Anne's University Hospital and Faculty of Medicine, Masaryk University, Brno, Czech Republic $u Multimodal and Functional Neuroimaging Research Group, CEITEC-Central European Institute of Technology, Masaryk University, Brno, Czech Republic $1 https://orcid.org/https://orcid.org/0000000254036135
700    1_
$a Mikl, Michal $u Multimodal and Functional Neuroimaging Research Group, CEITEC-Central European Institute of Technology, Masaryk University, Brno, Czech Republic $1 https://orcid.org/http://orcid.org/000000031190346X
700    1_
$a Gajdoš, Martin $u Multimodal and Functional Neuroimaging Research Group, CEITEC-Central European Institute of Technology, Masaryk University, Brno, Czech Republic $1 https://orcid.org/http://orcid.org/0000000327807472
700    1_
$a Vojtíšek, Lubomír $u Multimodal and Functional Neuroimaging Research Group, CEITEC-Central European Institute of Technology, Masaryk University, Brno, Czech Republic $1 https://orcid.org/http://orcid.org/0000000240276568 $7 xx0331412
700    1_
$a Bartoň, Marek $u Multimodal and Functional Neuroimaging Research Group, CEITEC-Central European Institute of Technology, Masaryk University, Brno, Czech Republic
700    1_
$a Strýček, Ondřej $u First Department of Neurology, St. Anne's University Hospital and Faculty of Medicine, Masaryk University, Brno, Czech Republic $1 https://orcid.org/http://orcid.org/0000000336369056
700    1_
$a Pail, Martin $u First Department of Neurology, St. Anne's University Hospital and Faculty of Medicine, Masaryk University, Brno, Czech Republic $1 https://orcid.org/http://orcid.org/0000000320594822
700    1_
$a Brázdil, Milan $u First Department of Neurology, St. Anne's University Hospital and Faculty of Medicine, Masaryk University, Brno, Czech Republic $u Multimodal and Functional Neuroimaging Research Group, CEITEC-Central European Institute of Technology, Masaryk University, Brno, Czech Republic $1 https://orcid.org/http://orcid.org/0000000179792343
700    1_
$a Rektor, Ivan $u First Department of Neurology, St. Anne's University Hospital and Faculty of Medicine, Masaryk University, Brno, Czech Republic. ivan.rektor@fnusa.cz $u Multimodal and Functional Neuroimaging Research Group, CEITEC-Central European Institute of Technology, Masaryk University, Brno, Czech Republic. ivan.rektor@fnusa.cz $1 https://orcid.org/http://orcid.org/0000000296357404
773    0_
$w MED00182195 $t Scientific reports $x 2045-2322 $g Roč. 12, č. 1 (2022), s. 15158
856    41
$u https://pubmed.ncbi.nlm.nih.gov/36071087 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20221017 $b ABA008
991    __
$a 20250423101401 $b ABA008
999    __
$a ok $b bmc $g 1854270 $s 1175750
BAS    __
$a 3
BAS    __
$a PreBMC
BMC    __
$a 2022 $b 12 $c 1 $d 15158 $e 20220907 $i 2045-2322 $m Scientific reports $n Sci Rep $x MED00182195
GRA    __
$a NU21-04-00254 $p Czech Health Research Council
GRA    __
$a LM2018129 Czech-BioImaging $p MEYS CR
LZP    __
$a Pubmed-20221017

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...