Acute efficacy of contiguous versus temporally discontiguous point-by-point radiofrequency pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a randomized study
B. Aldhoon, P. Peichl, P. Osmančík, P. Konečný, J. Kautzner, D. Wichterle
Language English Country Netherlands
Document type Journal Article, Randomized Controlled Trial
NLK
ProQuest Central
from 1997-07-01 to 1 year ago
Medline Complete (EBSCOhost)
from 2011-01-01 to 1 year ago
Health & Medicine (ProQuest)
from 1997-07-01 to 1 year ago
- MeSH
- Adenosine MeSH
- Atrial Fibrillation * surgery MeSH
- Catheter Ablation * MeSH
- Humans MeSH
- Recurrence MeSH
- Pulmonary Veins * surgery MeSH
- Treatment Outcome MeSH
- Check Tag
- Humans MeSH
- Male MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Randomized Controlled Trial MeSH
PURPOSE: Durable pulmonary vein (PV) isolation (PVI) determines the clinical success of catheter ablation for atrial fibrillation. In this randomized study, we investigated whether the temporally discontiguous deployment of ablation lesions adversely affected the acute efficacy of PVI. METHODS: Thirty-six consecutive patients with drug-refractory paroxysmal atrial fibrillation (aged 59 ± 11, 58% males) were randomized 1:1 to either discontiguous (D-PVI) or contiguous (C-PVI) encircling radiofrequency (RF) lesions around ipsilateral PVs. A contact force-sensing catheter was used targeting a final interlesion distance < 6 mm and the ablation index of 400-450 (anterior wall) and 300-350 (posterior wall). The study endpoint was defined as failure of first-pass PVI or acute PV reconnection during a waiting time (> 30 min) followed by adenosine challenge. RESULTS: The total RF time, number of RF lesions, and mean interlesion distance were comparable in both groups. Total endpoint rates were 1/36 (3%) in the D-PVI vs 4/36 (11%) in the C-PVI groups; P = 0.34 for superiority, P = 0.008 for non-inferiority. Adenosine-induced reconnection of right PVs was the only endpoint in the D-PVI group. In the C-PVI group, first-pass PVI failed in 2 right PVs and spontaneous reconnection occurred in 2 other circles (left and right PVs). CONCLUSION: Temporally discontiguous deployment of RF lesions is not associated with lower procedural PVI efficacy when strict criteria for interlesion distance and ablation index are applied. The development of local edema around each ablation site does not prevent effective RF lesion formation at adjacent positions. TRIAL REGISTRATION: clinicaltrials.gov (NCT03332862).
1st Faculty of Medicine Charles University Prague Czech Republic
3rd Faculty of Medicine Charles University Prague Czech Republic
Institute for Clinical and Experimental Medicine Prague Czech Republic
University Hospital Kralovske Vinohrady Prague Czech Republic
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc22024609
- 003
- CZ-PrNML
- 005
- 20221031100445.0
- 007
- ta
- 008
- 221017s2022 ne f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1007/s10840-021-01113-9 $2 doi
- 035 __
- $a (PubMed)34988847
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a ne
- 100 1_
- $a Aldhoon, Bashar $u Institute for Clinical and Experimental Medicine, Prague, Czech Republic $1 https://orcid.org/http://orcid.org/000000021845847X
- 245 10
- $a Acute efficacy of contiguous versus temporally discontiguous point-by-point radiofrequency pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a randomized study / $c B. Aldhoon, P. Peichl, P. Osmančík, P. Konečný, J. Kautzner, D. Wichterle
- 520 9_
- $a PURPOSE: Durable pulmonary vein (PV) isolation (PVI) determines the clinical success of catheter ablation for atrial fibrillation. In this randomized study, we investigated whether the temporally discontiguous deployment of ablation lesions adversely affected the acute efficacy of PVI. METHODS: Thirty-six consecutive patients with drug-refractory paroxysmal atrial fibrillation (aged 59 ± 11, 58% males) were randomized 1:1 to either discontiguous (D-PVI) or contiguous (C-PVI) encircling radiofrequency (RF) lesions around ipsilateral PVs. A contact force-sensing catheter was used targeting a final interlesion distance < 6 mm and the ablation index of 400-450 (anterior wall) and 300-350 (posterior wall). The study endpoint was defined as failure of first-pass PVI or acute PV reconnection during a waiting time (> 30 min) followed by adenosine challenge. RESULTS: The total RF time, number of RF lesions, and mean interlesion distance were comparable in both groups. Total endpoint rates were 1/36 (3%) in the D-PVI vs 4/36 (11%) in the C-PVI groups; P = 0.34 for superiority, P = 0.008 for non-inferiority. Adenosine-induced reconnection of right PVs was the only endpoint in the D-PVI group. In the C-PVI group, first-pass PVI failed in 2 right PVs and spontaneous reconnection occurred in 2 other circles (left and right PVs). CONCLUSION: Temporally discontiguous deployment of RF lesions is not associated with lower procedural PVI efficacy when strict criteria for interlesion distance and ablation index are applied. The development of local edema around each ablation site does not prevent effective RF lesion formation at adjacent positions. TRIAL REGISTRATION: clinicaltrials.gov (NCT03332862).
- 650 _2
- $a adenosin $7 D000241
- 650 12
- $a fibrilace síní $x chirurgie $7 D001281
- 650 12
- $a katetrizační ablace $7 D017115
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 12
- $a venae pulmonales $x chirurgie $7 D011667
- 650 _2
- $a recidiva $7 D012008
- 650 _2
- $a výsledek terapie $7 D016896
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a randomizované kontrolované studie $7 D016449
- 700 1_
- $a Peichl, Petr $u Institute for Clinical and Experimental Medicine, Prague, Czech Republic
- 700 1_
- $a Osmančík, Pavel $u University Hospital Kralovske Vinohrady, Prague, Czech Republic $u Third Faculty of Medicine, Charles University, Prague, Czech Republic
- 700 1_
- $a Konečný, Petr $u Institute for Clinical and Experimental Medicine, Prague, Czech Republic
- 700 1_
- $a Kautzner, Josef $u Institute for Clinical and Experimental Medicine, Prague, Czech Republic
- 700 1_
- $a Wichterle, Dan $u Institute for Clinical and Experimental Medicine, Prague, Czech Republic $u First Faculty of Medicine, Charles University, Prague, Czech Republic
- 773 0_
- $w MED00008134 $t Journal of interventional cardiac electrophysiology $x 1572-8595 $g Roč. 64, č. 3 (2022), s. 661-667
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/34988847 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y p $z 0
- 990 __
- $a 20221017 $b ABA008
- 991 __
- $a 20221031100443 $b ABA008
- 999 __
- $a ok $b bmc $g 1854374 $s 1175899
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2022 $b 64 $c 3 $d 661-667 $e 20220106 $i 1572-8595 $m Journal of interventional cardiac electrophysiology $n J Interv Card Electrophysiol $x MED00008134
- LZP __
- $a Pubmed-20221017