Robust and high-throughput lipidomic quantitation of human blood samples using flow injection analysis with tandem mass spectrometry for clinical use

J. Idkowiak, R. Jirásko, D. Kolářová, J. Bártl, T. Hájek, M. Antonelli, Z. Vaňková, D. Wolrab, R. Hrstka, H. Študentová, B. Melichar, K. Pešková, M. Holčapek

. 2023 ; 415 (5) : 935-951. [pub] 20230104

Jazyk angličtina Země Německo

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/bmc23004320
E-zdroje Online Plný text

NLK ProQuest Central od 2011-01-01 do Před 1 rokem
Medline Complete (EBSCOhost) od 2003-01-01 do Před 1 rokem
Health & Medicine (ProQuest) od 2011-01-01 do Před 1 rokem

Direct infusion of lipid extracts into the ion source of a mass spectrometer is a well-established method for lipid analysis. In most cases, nanofluidic devices are used for sample introduction. However, flow injection analysis (FIA) based on sample infusion from a chromatographic pump can offer a simple alternative to shotgun-based approaches. Here, we describe important modification of a method based on FIA and tandem mass spectrometry (MS/MS). We focus on minimizing contamination of the FIA/MS both to render the lipidomic platform more robust and to increase its capacity and applicability for long-sequence measurements required in clinical applications. Robust validation of the developed method confirms its suitability for lipid quantitation in human plasma analysis. Measurements of standard human plasma reference material (NIST SRM 1950) and a set of plasma samples collected from kidney cancer patients and from healthy volunteers yielded highly similar results between FIA-MS/MS and ultra-high-performance supercritical fluid chromatography (UHPSFC)/MS, thereby demonstrating that all modifications have practically no effect on the statistical output. Newly modified FIA-MS/MS allows for the quantitation of 141 lipid species in plasma (11 major lipid classes) within 5.7 min. Finally, we tested the method in a clinical laboratory of the General University Hospital in Prague. In the clinical setting, the method capacity reached 257 samples/day. We also show similar performance of the classification models trained based on the results obtained in clinical settings and the analytical laboratory at the University of Pardubice. Together, these findings demonstrate the high potential of the modified FIA-MS/MS for application in clinical laboratories to measure plasma and serum lipid profiles.

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc23004320
003      
CZ-PrNML
005      
20230425141304.0
007      
ta
008      
230418s2023 gw f 000 0|eng||
009      
AR
024    7_
$a 10.1007/s00216-022-04490-w $2 doi
035    __
$a (PubMed)36598539
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a gw
100    1_
$a Idkowiak, Jakub $u Faculty of Chemical Technology, Department of Analytical Chemistry, University of Pardubice, Studentská 573, 532 10, Pardubice, Czech Republic
245    10
$a Robust and high-throughput lipidomic quantitation of human blood samples using flow injection analysis with tandem mass spectrometry for clinical use / $c J. Idkowiak, R. Jirásko, D. Kolářová, J. Bártl, T. Hájek, M. Antonelli, Z. Vaňková, D. Wolrab, R. Hrstka, H. Študentová, B. Melichar, K. Pešková, M. Holčapek
520    9_
$a Direct infusion of lipid extracts into the ion source of a mass spectrometer is a well-established method for lipid analysis. In most cases, nanofluidic devices are used for sample introduction. However, flow injection analysis (FIA) based on sample infusion from a chromatographic pump can offer a simple alternative to shotgun-based approaches. Here, we describe important modification of a method based on FIA and tandem mass spectrometry (MS/MS). We focus on minimizing contamination of the FIA/MS both to render the lipidomic platform more robust and to increase its capacity and applicability for long-sequence measurements required in clinical applications. Robust validation of the developed method confirms its suitability for lipid quantitation in human plasma analysis. Measurements of standard human plasma reference material (NIST SRM 1950) and a set of plasma samples collected from kidney cancer patients and from healthy volunteers yielded highly similar results between FIA-MS/MS and ultra-high-performance supercritical fluid chromatography (UHPSFC)/MS, thereby demonstrating that all modifications have practically no effect on the statistical output. Newly modified FIA-MS/MS allows for the quantitation of 141 lipid species in plasma (11 major lipid classes) within 5.7 min. Finally, we tested the method in a clinical laboratory of the General University Hospital in Prague. In the clinical setting, the method capacity reached 257 samples/day. We also show similar performance of the classification models trained based on the results obtained in clinical settings and the analytical laboratory at the University of Pardubice. Together, these findings demonstrate the high potential of the modified FIA-MS/MS for application in clinical laboratories to measure plasma and serum lipid profiles.
650    _2
$a lidé $7 D006801
650    12
$a tandemová hmotnostní spektrometrie $x metody $7 D053719
650    12
$a lipidomika $x metody $7 D000081362
650    _2
$a průtoková injekční analýza $7 D017022
650    _2
$a krevní plazma $x chemie $7 D010949
650    _2
$a lipidy $x analýza $7 D008055
655    _2
$a časopisecké články $7 D016428
700    1_
$a Jirásko, Robert $u Faculty of Chemical Technology, Department of Analytical Chemistry, University of Pardubice, Studentská 573, 532 10, Pardubice, Czech Republic. robert.jirasko@upce.cz $1 https://orcid.org/0000000157955017 $7 xx0090410
700    1_
$a Kolářová, Denisa $u Faculty of Chemical Technology, Department of Analytical Chemistry, University of Pardubice, Studentská 573, 532 10, Pardubice, Czech Republic
700    1_
$a Bártl, Josef $u Department of Pediatrics and Inherited Metabolic Disorders, Charles University, First Faculty of Medicine and General University Hospital in Prague, Ke Karlovu 2, 12808 2, Prague, Czech Republic
700    1_
$a Hájek, Tomáš $u Faculty of Chemical Technology, Department of Analytical Chemistry, University of Pardubice, Studentská 573, 532 10, Pardubice, Czech Republic
700    1_
$a Antonelli, Michela $u Faculty of Chemical Technology, Department of Analytical Chemistry, University of Pardubice, Studentská 573, 532 10, Pardubice, Czech Republic
700    1_
$a Vaňková, Zuzana $u Faculty of Chemical Technology, Department of Analytical Chemistry, University of Pardubice, Studentská 573, 532 10, Pardubice, Czech Republic
700    1_
$a Wolrab, Denise $u Faculty of Chemical Technology, Department of Analytical Chemistry, University of Pardubice, Studentská 573, 532 10, Pardubice, Czech Republic
700    1_
$a Hrstka, Roman $u Research Centre for Applied Molecular Oncology, Masaryk Memorial Cancer Institute, Žlutý kopec 7, 656 53, Brno, Czech Republic
700    1_
$a Študentová, Hana $u Medical School and Teaching Hospital, Department of Oncology, Palacký University, I.P. Pavlova 6, 775 20, Olomouc, Czech Republic
700    1_
$a Melichar, Bohuslav $u Medical School and Teaching Hospital, Department of Oncology, Palacký University, I.P. Pavlova 6, 775 20, Olomouc, Czech Republic
700    1_
$a Pešková, Karolína $u Department of Pediatrics and Inherited Metabolic Disorders, Charles University, First Faculty of Medicine and General University Hospital in Prague, Ke Karlovu 2, 12808 2, Prague, Czech Republic
700    1_
$a Holčapek, Michal $u Faculty of Chemical Technology, Department of Analytical Chemistry, University of Pardubice, Studentská 573, 532 10, Pardubice, Czech Republic
773    0_
$w MED00006638 $t Analytical and bioanalytical chemistry $x 1618-2650 $g Roč. 415, č. 5 (2023), s. 935-951
856    41
$u https://pubmed.ncbi.nlm.nih.gov/36598539 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y p $z 0
990    __
$a 20230418 $b ABA008
991    __
$a 20230425141300 $b ABA008
999    __
$a ok $b bmc $g 1924790 $s 1190529
BAS    __
$a 3
BAS    __
$a PreBMC-MEDLINE
BMC    __
$a 2023 $b 415 $c 5 $d 935-951 $e 20230104 $i 1618-2650 $m Analytical and bioanalytical chemistry $n Anal Bioanal Chem $x MED00006638
LZP    __
$a Pubmed-20230418

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...