Portable household air purifiers are widely used devices designed to maintain a high-quality level of indoor air. Portable air purifiers equipped with the high-efficiency air (HEPA) filter served 100 h in a household space occupied by two adults without any symptoms of respiratory tract infection. The main objective of the study was to determine microbial contamination on the HEPA filter and to investigate if the selected nanotextile monolayer made of polyamide 6 (PA6) nanofibers can capture potential microorganisms when installed downstream of the HEPA filter as the final filtration medium. Samples were taken from the inlet and outlet surfaces. Samples from the nanotextile were collected in the same manner as from the HEPA filter. QIAStat DX® 1.0 Analyzer using the Respiratory SARS CoV-2 Panel multiplex PCR detection system was selected for microorganism detection. Adenovirus was detected on the inlet surface of the HEPA filter. The outlet surface of the filter contained no viruses included in the Respiratory SARS CoV-2 Panel portfolio. The nanotextile monolayer was replaced twice during the 100 h of operation, so three pieces were used and all contained coronavirus 229 E. Coronavirus 229 E was then detected in the nasopharynx of one of the members of the household as well. It may be assumed that the selected nanotextile is capable of capturing a virus of a small size.
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc24008667
- 003
- CZ-PrNML
- 005
- 20240509114848.0
- 007
- ta
- 008
- 240509s2024 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1007/s12223-024-01137-4 $2 doi
- 035 __
- $a (PubMed)38353790
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Obitková, Daniela $u Department of Health Care Disciplines and Population Protection, Faculty of Biomedical Engineering, Czech Technical University in Prague , Náměstí Sítná, 3105, Kladno, Czech Republic $1 https://orcid.org/0000000174376383
- 245 10
- $a Virus removal by high-efficiency air (HEPA) filters and filtration capacity enhancement by nanotextiles: a pilot study / $c D. Obitková, M. Mráz, E. Pavlík
- 520 9_
- $a Portable household air purifiers are widely used devices designed to maintain a high-quality level of indoor air. Portable air purifiers equipped with the high-efficiency air (HEPA) filter served 100 h in a household space occupied by two adults without any symptoms of respiratory tract infection. The main objective of the study was to determine microbial contamination on the HEPA filter and to investigate if the selected nanotextile monolayer made of polyamide 6 (PA6) nanofibers can capture potential microorganisms when installed downstream of the HEPA filter as the final filtration medium. Samples were taken from the inlet and outlet surfaces. Samples from the nanotextile were collected in the same manner as from the HEPA filter. QIAStat DX® 1.0 Analyzer using the Respiratory SARS CoV-2 Panel multiplex PCR detection system was selected for microorganism detection. Adenovirus was detected on the inlet surface of the HEPA filter. The outlet surface of the filter contained no viruses included in the Respiratory SARS CoV-2 Panel portfolio. The nanotextile monolayer was replaced twice during the 100 h of operation, so three pieces were used and all contained coronavirus 229 E. Coronavirus 229 E was then detected in the nasopharynx of one of the members of the household as well. It may be assumed that the selected nanotextile is capable of capturing a virus of a small size.
- 650 _2
- $a lidé $7 D006801
- 650 12
- $a vzduchové filtry $7 D061808
- 650 _2
- $a pilotní projekty $7 D010865
- 650 12
- $a syndrom akutního respiračního selhání $7 D045169
- 650 _2
- $a filtrace $7 D005374
- 650 _2
- $a SARS-CoV-2 $7 D000086402
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Mráz, Milan $u Department of Health Care Disciplines and Population Protection, Faculty of Biomedical Engineering, Czech Technical University in Prague , Náměstí Sítná, 3105, Kladno, Czech Republic. milan.mraz@fbmi.cvut.cz $1 https://orcid.org/0000000298412833
- 700 1_
- $a Pavlík, Emil $u Faculty of Biomedical Engineering, Czech Technical University in Prague, Náměstí Sítná, 3105, Kladno, Czech Republic $u Medical Immunology and Microbiology Institute, 1st Medical Faculty, Charles University, Studničkova 7, Prague, Czech Republic $1 https://orcid.org/000000029132163X $7 jo2002104140
- 773 0_
- $w MED00011005 $t Folia microbiologica $x 1874-9356 $g Roč. 69, č. 2 (2024), s. 459-464
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/38353790 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20240509 $b ABA008
- 991 __
- $a 20240509114843 $b ABA008
- 999 __
- $a ok $b bmc $g 2088887 $s 1218448
- BAS __
- $a 3
- BAS __
- $a PreBMC-MEDLINE
- BMC __
- $a 2024 $b 69 $c 2 $d 459-464 $e 20240214 $i 1874-9356 $m Folia microbiologica $n Folia microbiol. (Prague) $x MED00011005
- LZP __
- $a Pubmed-20240509