-
Something wrong with this record ?
Accuracy and Feasibility of Real-time Continuous Glucose Monitoring in Critically Ill Patients After Abdominal Surgery and Solid Organ Transplantation
B. Voglová Hagerf, M. Protus, L. Nemetova, M. Mraz, E. Kieslichova, E. Uchytilova, V. Indrova, J. Lelito, P. Girman, M. Haluzík, J. Franekova, V. Svirlochova, DC. Klonoff, MA. Kohn, A. Jabor
Language English Country United States
Document type Journal Article
Grant support
National Institute for Research of Metabolic and Cardiovascular Diseases (Programme EXCELES, ID Project No. LX22NPO5104) - Funded by the European Union - Next Generation EU) MH CZ - DRO (Institute for Clinical and Experimental Medicine - IKEM, IN 00023001)
Cooperatio Programme, section Medical Diagnostics and Basic Medical Sciences, Charles University, Prague, Czech Republic
NLK
Free Medical Journals
from 1978
Open Access Digital Library
from 1978-01-01 to 6 months ago
Open Access Digital Library
from 2000-01-01 to 6 months ago
Medline Complete (EBSCOhost)
from 1978-01-01
PubMed
38412005
DOI
10.2337/dc23-1663
Knihovny.cz E-resources
- MeSH
- Abdomen surgery MeSH
- Adult MeSH
- Continuous Glucose Monitoring MeSH
- Blood Glucose * analysis MeSH
- Critical Illness * MeSH
- Middle Aged MeSH
- Humans MeSH
- Monitoring, Physiologic methods MeSH
- Aged MeSH
- Feasibility Studies MeSH
- Organ Transplantation MeSH
- Check Tag
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
OBJECTIVE: Glycemia management in critical care is posing a challenge in frequent measuring and adequate insulin dose adjustment. In recent years, continuous glucose measurement has gained accuracy and reliability in outpatient and inpatient settings. The aim of this study was to assess the feasibility and accuracy of real-time continuous glucose monitoring (CGM) in ICU patients after major abdominal surgery. RESEARCH DESIGN AND METHODS: We included patients undergoing pancreatic surgery and solid organ transplantation (liver, pancreas, islets of Langerhans, kidney) requiring an ICU stay after surgery. We used a Dexcom G6 sensor, placed in the infraclavicular region, for real-time CGM. Arterial blood glucose measured by the amperometric principle (ABL 800; Radiometer, Copenhagen, Denmark) served as a reference value and for calibration. Blood glucose was also routinely monitored by a StatStrip bedside glucose meter. Sensor accuracy was assessed by mean absolute relative difference (MARD), bias, modified Bland-Altman plot, and surveillance error grid for paired samples of glucose values from CGM and acid-base analyzer (ABL). RESULTS: We analyzed data from 61 patients and obtained 1,546 paired glucose values from CGM and ABL. Active sensor use was 95.1%. MARD was 9.4%, relative bias was 1.4%, and 92.8% of values fell in zone A, 6.1% fell in zone B, and 1.2% fell in zone C of the surveillance error grid. Median time in range was 78%, with minimum (<1%) time spent in hypoglycemia. StatStrip glucose meter MARD compared with ABL was 5.8%. CONCLUSIONS: Our study shows clinically applicable accuracy and reliability of Dexcom G6 CGM in postoperative ICU patients and a feasible alternative sensor placement site.
1st Faculty of Medicine Charles University Prague Czech Republic
3rd Faculty of Medicine Charles University Prague Czech Republic
Diabetes Research Institute Mills Peninsula Medical Center San Mateo CA
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc24013771
- 003
- CZ-PrNML
- 005
- 20240905133342.0
- 007
- ta
- 008
- 240725s2024 xxu f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.2337/dc23-1663 $2 doi
- 035 __
- $a (PubMed)38412005
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xxu
- 100 1_
- $a Voglová Hagerf, Barbora $u Department of Diabetes, Diabetes Centre, Institute for Clinical and Experimental Medicine, Prague, Czech Republic $u First Faculty of Medicine, Charles University, Prague, Czech Republic $1 https://orcid.org/0000000171325134
- 245 10
- $a Accuracy and Feasibility of Real-time Continuous Glucose Monitoring in Critically Ill Patients After Abdominal Surgery and Solid Organ Transplantation / $c B. Voglová Hagerf, M. Protus, L. Nemetova, M. Mraz, E. Kieslichova, E. Uchytilova, V. Indrova, J. Lelito, P. Girman, M. Haluzík, J. Franekova, V. Svirlochova, DC. Klonoff, MA. Kohn, A. Jabor
- 520 9_
- $a OBJECTIVE: Glycemia management in critical care is posing a challenge in frequent measuring and adequate insulin dose adjustment. In recent years, continuous glucose measurement has gained accuracy and reliability in outpatient and inpatient settings. The aim of this study was to assess the feasibility and accuracy of real-time continuous glucose monitoring (CGM) in ICU patients after major abdominal surgery. RESEARCH DESIGN AND METHODS: We included patients undergoing pancreatic surgery and solid organ transplantation (liver, pancreas, islets of Langerhans, kidney) requiring an ICU stay after surgery. We used a Dexcom G6 sensor, placed in the infraclavicular region, for real-time CGM. Arterial blood glucose measured by the amperometric principle (ABL 800; Radiometer, Copenhagen, Denmark) served as a reference value and for calibration. Blood glucose was also routinely monitored by a StatStrip bedside glucose meter. Sensor accuracy was assessed by mean absolute relative difference (MARD), bias, modified Bland-Altman plot, and surveillance error grid for paired samples of glucose values from CGM and acid-base analyzer (ABL). RESULTS: We analyzed data from 61 patients and obtained 1,546 paired glucose values from CGM and ABL. Active sensor use was 95.1%. MARD was 9.4%, relative bias was 1.4%, and 92.8% of values fell in zone A, 6.1% fell in zone B, and 1.2% fell in zone C of the surveillance error grid. Median time in range was 78%, with minimum (<1%) time spent in hypoglycemia. StatStrip glucose meter MARD compared with ABL was 5.8%. CONCLUSIONS: Our study shows clinically applicable accuracy and reliability of Dexcom G6 CGM in postoperative ICU patients and a feasible alternative sensor placement site.
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 12
- $a krevní glukóza $x analýza $7 D001786
- 650 _2
- $a lidé středního věku $7 D008875
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 12
- $a kritický stav $7 D016638
- 650 _2
- $a senioři $7 D000368
- 650 _2
- $a břicho $x chirurgie $7 D000005
- 650 _2
- $a transplantace orgánů $7 D016377
- 650 _2
- $a studie proveditelnosti $7 D005240
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a monitorování fyziologických funkcí $x metody $7 D008991
- 650 _2
- $a kontinuální monitorování glukózy $7 D000095583
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Protus, Marek $u First Faculty of Medicine, Charles University, Prague, Czech Republic $u Department of Anesthesiology, Resuscitation and Intensive Care, Institute for Clinical and Experimental Medicine, Prague, Czech Republic $1 https://orcid.org/0000000265956877
- 700 1_
- $a Nemetova, Lenka $u Department of Diabetes, Diabetes Centre, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
- 700 1_
- $a Mraz, Milos $u Department of Diabetes, Diabetes Centre, Institute for Clinical and Experimental Medicine, Prague, Czech Republic $u First Faculty of Medicine, Charles University, Prague, Czech Republic $1 https://orcid.org/0000000153224612 $7 xx0119173
- 700 1_
- $a Kieslichova, Eva $u First Faculty of Medicine, Charles University, Prague, Czech Republic $u Department of Anesthesiology, Resuscitation and Intensive Care, Institute for Clinical and Experimental Medicine, Prague, Czech Republic $1 https://orcid.org/000000023930623X
- 700 1_
- $a Uchytilova, Eva $u First Faculty of Medicine, Charles University, Prague, Czech Republic $u Department of Anesthesiology, Resuscitation and Intensive Care, Institute for Clinical and Experimental Medicine, Prague, Czech Republic $1 https://orcid.org/0000000204124137
- 700 1_
- $a Indrova, Veronika $u Department of Anesthesiology, Resuscitation and Intensive Care, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
- 700 1_
- $a Lelito, Jan $u Department of Anesthesiology, Resuscitation and Intensive Care, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
- 700 1_
- $a Girman, Peter $u Department of Diabetes, Diabetes Centre, Institute for Clinical and Experimental Medicine, Prague, Czech Republic $1 https://orcid.org/0000000309448189 $7 xx0081892
- 700 1_
- $a Haluzík, Martin $u Department of Diabetes, Diabetes Centre, Institute for Clinical and Experimental Medicine, Prague, Czech Republic $u First Faculty of Medicine, Charles University, Prague, Czech Republic $1 https://orcid.org/0000000202016888 $7 xx0000707
- 700 1_
- $a Franekova, Janka $u Department of Laboratory Methods, Institute for Clinical and Experimental Medicine, Prague, Czech Republic $u Third Faculty of Medicine, Charles University, Prague, Czech Republic $1 https://orcid.org/0000000250947724
- 700 1_
- $a Svirlochova, Veronika $u Department of Laboratory Methods, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
- 700 1_
- $a Klonoff, David C $u Diabetes Research Institute, Mills-Peninsula Medical Center, San Mateo, CA $1 https://orcid.org/0000000163946862 $7 xx0073553
- 700 1_
- $a Kohn, Michael A $u University of California San Francisco, San Francisco, CA $1 https://orcid.org/0000000154595044
- 700 1_
- $a Jabor, Antonin $u Department of Laboratory Methods, Institute for Clinical and Experimental Medicine, Prague, Czech Republic $u Third Faculty of Medicine, Charles University, Prague, Czech Republic $1 https://orcid.org/0000000241443129
- 773 0_
- $w MED00001380 $t Diabetes care $x 1935-5548 $g Roč. 47, č. 6 (2024), s. 956-963
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/38412005 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20240725 $b ABA008
- 991 __
- $a 20240905133336 $b ABA008
- 999 __
- $a ok $b bmc $g 2143527 $s 1225637
- BAS __
- $a 3
- BAS __
- $a PreBMC-MEDLINE
- BMC __
- $a 2024 $b 47 $c 6 $d 956-963 $e 20240601 $i 1935-5548 $m Diabetes care $n Diabetes Care $x MED00001380
- GRA __
- $p National Institute for Research of Metabolic and Cardiovascular Diseases (Programme EXCELES, ID Project No. LX22NPO5104) - Funded by the European Union - Next Generation EU) MH CZ - DRO (Institute for Clinical and Experimental Medicine - IKEM, IN 00023001)
- GRA __
- $p Cooperatio Programme, section Medical Diagnostics and Basic Medical Sciences, Charles University, Prague, Czech Republic
- LZP __
- $a Pubmed-20240725