Reducing thermal noise in high-resolution quantitative magnetic resonance imaging rotating frame relaxation mapping of the human brain at 3 T

S. Ponticorvo, A. Canna, S. Moeller, M. Akcakaya, GJ. Metzger, P. Filip, LE. Eberly, S. Michaeli, S. Mangia

. 2024 ; 37 (12) : e5228. [pub] 20240821

Language English Country England, Great Britain

Document type Journal Article

Grant support
P41 EB027061 NIBIB NIH HHS - United States
R01 EB032830 NIBIB NIH HHS - United States
R01 EB032830 NIH HHS - United States
P41 EB027061 NIH HHS - United States

Quantitative maps of rotating frame relaxation (RFR) time constants are sensitive and useful magnetic resonance imaging tools with which to evaluate tissue integrity in vivo. However, to date, only moderate image resolutions of 1.6 x 1.6 x 3.6 mm3 have been used for whole-brain coverage RFR mapping in humans at 3 T. For more precise morphometrical examinations, higher spatial resolutions are desirable. Towards achieving the long-term goal of increasing the spatial resolution of RFR mapping without increasing scan times, we explore the use of the recently introduced Transform domain NOise Reduction with DIstribution Corrected principal component analysis (T-NORDIC) algorithm for thermal noise reduction. RFR acquisitions at 3 T were obtained from eight healthy participants (seven males and one female) aged 52 ± 20 years, including adiabatic T1ρ, T2ρ, and nonadiabatic Relaxation Along a Fictitious Field (RAFF) in the rotating frame of rank n = 4 (RAFF4) with both 1.6 x 1.6 x 3.6 mm3 and 1.25 x 1.25 x 2 mm3 image resolutions. We compared RFR values and their confidence intervals (CIs) obtained from fitting the denoised versus nondenoised images, at both voxel and regional levels separately for each resolution and RFR metric. The comparison of metrics obtained from denoised versus nondenoised images was performed with a two-sample paired t-test and statistical significance was set at p less than 0.05 after Bonferroni correction for multiple comparisons. The use of T-NORDIC on the RFR images prior to the fitting procedure decreases the uncertainty of parameter estimation (lower CIs) at both spatial resolutions. The effect was particularly prominent at high-spatial resolution for RAFF4. Moreover, T-NORDIC did not degrade map quality, and it had minimal impact on the RFR values. Denoising RFR images with T-NORDIC improves parameter estimation while preserving the image quality and accuracy of all RFR maps, ultimately enabling high-resolution RFR mapping in scan times that are suitable for clinical settings.

References provided by Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc25003300
003      
CZ-PrNML
005      
20250206104233.0
007      
ta
008      
250121s2024 enk f 000 0|eng||
009      
AR
024    7_
$a 10.1002/nbm.5228 $2 doi
035    __
$a (PubMed)39169274
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a enk
100    1_
$a Ponticorvo, Sara $u Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA $1 https://orcid.org/0000000279331608
245    10
$a Reducing thermal noise in high-resolution quantitative magnetic resonance imaging rotating frame relaxation mapping of the human brain at 3 T / $c S. Ponticorvo, A. Canna, S. Moeller, M. Akcakaya, GJ. Metzger, P. Filip, LE. Eberly, S. Michaeli, S. Mangia
520    9_
$a Quantitative maps of rotating frame relaxation (RFR) time constants are sensitive and useful magnetic resonance imaging tools with which to evaluate tissue integrity in vivo. However, to date, only moderate image resolutions of 1.6 x 1.6 x 3.6 mm3 have been used for whole-brain coverage RFR mapping in humans at 3 T. For more precise morphometrical examinations, higher spatial resolutions are desirable. Towards achieving the long-term goal of increasing the spatial resolution of RFR mapping without increasing scan times, we explore the use of the recently introduced Transform domain NOise Reduction with DIstribution Corrected principal component analysis (T-NORDIC) algorithm for thermal noise reduction. RFR acquisitions at 3 T were obtained from eight healthy participants (seven males and one female) aged 52 ± 20 years, including adiabatic T1ρ, T2ρ, and nonadiabatic Relaxation Along a Fictitious Field (RAFF) in the rotating frame of rank n = 4 (RAFF4) with both 1.6 x 1.6 x 3.6 mm3 and 1.25 x 1.25 x 2 mm3 image resolutions. We compared RFR values and their confidence intervals (CIs) obtained from fitting the denoised versus nondenoised images, at both voxel and regional levels separately for each resolution and RFR metric. The comparison of metrics obtained from denoised versus nondenoised images was performed with a two-sample paired t-test and statistical significance was set at p less than 0.05 after Bonferroni correction for multiple comparisons. The use of T-NORDIC on the RFR images prior to the fitting procedure decreases the uncertainty of parameter estimation (lower CIs) at both spatial resolutions. The effect was particularly prominent at high-spatial resolution for RAFF4. Moreover, T-NORDIC did not degrade map quality, and it had minimal impact on the RFR values. Denoising RFR images with T-NORDIC improves parameter estimation while preserving the image quality and accuracy of all RFR maps, ultimately enabling high-resolution RFR mapping in scan times that are suitable for clinical settings.
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a ženské pohlaví $7 D005260
650    12
$a magnetická rezonanční tomografie $x metody $7 D008279
650    12
$a mozek $x diagnostické zobrazování $7 D001921
650    _2
$a lidé středního věku $7 D008875
650    12
$a poměr signál - šum $7 D059629
650    _2
$a dospělí $7 D000328
650    _2
$a algoritmy $7 D000465
650    _2
$a mapování mozku $7 D001931
650    _2
$a analýza hlavních komponent $7 D025341
650    _2
$a rotace $7 D012399
650    _2
$a senioři $7 D000368
655    _2
$a časopisecké články $7 D016428
700    1_
$a Canna, Antonietta $u Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA $u Montreal Neurological Institute and Hospital, the Neuro, McGill University, Montréal, Quebec, Canada
700    1_
$a Moeller, Steen $u Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA
700    1_
$a Akcakaya, Mehmet $u Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA $u Electrical and Computer Engineering, University of Minnesota, Minneapolis, Minnesota, USA
700    1_
$a Metzger, Gregory J $u Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA
700    1_
$a Filip, Pavel $u Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA $u Department of Neurology, First Faculty of Medicine and General University Hospital, Charles University, Prague, Czech Republic $1 https://orcid.org/0000000156565164 $7 xx0247515
700    1_
$a Eberly, Lynn E $u Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA $u Division of Biostatistics, School of Public Health, University of Minnesota, Minneapolis, Minnesota, USA
700    1_
$a Michaeli, Shalom $u Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA
700    1_
$a Mangia, Silvia $u Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA $1 https://orcid.org/0000000163414516
773    0_
$w MED00003529 $t NMR in biomedicine $x 1099-1492 $g Roč. 37, č. 12 (2024), s. e5228
856    41
$u https://pubmed.ncbi.nlm.nih.gov/39169274 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20250121 $b ABA008
991    __
$a 20250206104229 $b ABA008
999    __
$a ok $b bmc $g 2263200 $s 1239307
BAS    __
$a 3
BAS    __
$a PreBMC-MEDLINE
BMC    __
$a 2024 $b 37 $c 12 $d e5228 $e 20240821 $i 1099-1492 $m NMR in biomedicine $n NMR Biomed $x MED00003529
GRA    __
$a P41 EB027061 $p NIBIB NIH HHS $2 United States
GRA    __
$a R01 EB032830 $p NIBIB NIH HHS $2 United States
GRA    __
$a R01 EB032830 $p NIH HHS $2 United States
GRA    __
$a P41 EB027061 $p NIH HHS $2 United States
LZP    __
$a Pubmed-20250121

Find record

Citation metrics

Loading data ...

Archiving options

Loading data ...