Reducing thermal noise in high-resolution quantitative magnetic resonance imaging rotating frame relaxation mapping of the human brain at 3 T
S. Ponticorvo, A. Canna, S. Moeller, M. Akcakaya, GJ. Metzger, P. Filip, LE. Eberly, S. Michaeli, S. Mangia
Language English Country England, Great Britain
Document type Journal Article
Grant support
P41 EB027061
NIBIB NIH HHS - United States
R01 EB032830
NIBIB NIH HHS - United States
R01 EB032830
NIH HHS - United States
P41 EB027061
NIH HHS - United States
PubMed
39169274
DOI
10.1002/nbm.5228
Knihovny.cz E-resources
- MeSH
- Algorithms MeSH
- Principal Component Analysis MeSH
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Magnetic Resonance Imaging * methods MeSH
- Brain Mapping MeSH
- Brain * diagnostic imaging MeSH
- Signal-To-Noise Ratio * MeSH
- Rotation MeSH
- Aged MeSH
- Check Tag
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
Quantitative maps of rotating frame relaxation (RFR) time constants are sensitive and useful magnetic resonance imaging tools with which to evaluate tissue integrity in vivo. However, to date, only moderate image resolutions of 1.6 x 1.6 x 3.6 mm3 have been used for whole-brain coverage RFR mapping in humans at 3 T. For more precise morphometrical examinations, higher spatial resolutions are desirable. Towards achieving the long-term goal of increasing the spatial resolution of RFR mapping without increasing scan times, we explore the use of the recently introduced Transform domain NOise Reduction with DIstribution Corrected principal component analysis (T-NORDIC) algorithm for thermal noise reduction. RFR acquisitions at 3 T were obtained from eight healthy participants (seven males and one female) aged 52 ± 20 years, including adiabatic T1ρ, T2ρ, and nonadiabatic Relaxation Along a Fictitious Field (RAFF) in the rotating frame of rank n = 4 (RAFF4) with both 1.6 x 1.6 x 3.6 mm3 and 1.25 x 1.25 x 2 mm3 image resolutions. We compared RFR values and their confidence intervals (CIs) obtained from fitting the denoised versus nondenoised images, at both voxel and regional levels separately for each resolution and RFR metric. The comparison of metrics obtained from denoised versus nondenoised images was performed with a two-sample paired t-test and statistical significance was set at p less than 0.05 after Bonferroni correction for multiple comparisons. The use of T-NORDIC on the RFR images prior to the fitting procedure decreases the uncertainty of parameter estimation (lower CIs) at both spatial resolutions. The effect was particularly prominent at high-spatial resolution for RAFF4. Moreover, T-NORDIC did not degrade map quality, and it had minimal impact on the RFR values. Denoising RFR images with T-NORDIC improves parameter estimation while preserving the image quality and accuracy of all RFR maps, ultimately enabling high-resolution RFR mapping in scan times that are suitable for clinical settings.
Center for Magnetic Resonance Research University of Minnesota Minneapolis Minnesota USA
Division of Biostatistics School of Public Health University of Minnesota Minneapolis Minnesota USA
Electrical and Computer Engineering University of Minnesota Minneapolis Minnesota USA
Montreal Neurological Institute and Hospital the Neuro McGill University Montréal Quebec Canada
References provided by Crossref.org
- 000
- 00000naa a2200000 a 4500
- 001
- bmc25003300
- 003
- CZ-PrNML
- 005
- 20250206104233.0
- 007
- ta
- 008
- 250121s2024 enk f 000 0|eng||
- 009
- AR
- 024 7_
- $a 10.1002/nbm.5228 $2 doi
- 035 __
- $a (PubMed)39169274
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a enk
- 100 1_
- $a Ponticorvo, Sara $u Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA $1 https://orcid.org/0000000279331608
- 245 10
- $a Reducing thermal noise in high-resolution quantitative magnetic resonance imaging rotating frame relaxation mapping of the human brain at 3 T / $c S. Ponticorvo, A. Canna, S. Moeller, M. Akcakaya, GJ. Metzger, P. Filip, LE. Eberly, S. Michaeli, S. Mangia
- 520 9_
- $a Quantitative maps of rotating frame relaxation (RFR) time constants are sensitive and useful magnetic resonance imaging tools with which to evaluate tissue integrity in vivo. However, to date, only moderate image resolutions of 1.6 x 1.6 x 3.6 mm3 have been used for whole-brain coverage RFR mapping in humans at 3 T. For more precise morphometrical examinations, higher spatial resolutions are desirable. Towards achieving the long-term goal of increasing the spatial resolution of RFR mapping without increasing scan times, we explore the use of the recently introduced Transform domain NOise Reduction with DIstribution Corrected principal component analysis (T-NORDIC) algorithm for thermal noise reduction. RFR acquisitions at 3 T were obtained from eight healthy participants (seven males and one female) aged 52 ± 20 years, including adiabatic T1ρ, T2ρ, and nonadiabatic Relaxation Along a Fictitious Field (RAFF) in the rotating frame of rank n = 4 (RAFF4) with both 1.6 x 1.6 x 3.6 mm3 and 1.25 x 1.25 x 2 mm3 image resolutions. We compared RFR values and their confidence intervals (CIs) obtained from fitting the denoised versus nondenoised images, at both voxel and regional levels separately for each resolution and RFR metric. The comparison of metrics obtained from denoised versus nondenoised images was performed with a two-sample paired t-test and statistical significance was set at p less than 0.05 after Bonferroni correction for multiple comparisons. The use of T-NORDIC on the RFR images prior to the fitting procedure decreases the uncertainty of parameter estimation (lower CIs) at both spatial resolutions. The effect was particularly prominent at high-spatial resolution for RAFF4. Moreover, T-NORDIC did not degrade map quality, and it had minimal impact on the RFR values. Denoising RFR images with T-NORDIC improves parameter estimation while preserving the image quality and accuracy of all RFR maps, ultimately enabling high-resolution RFR mapping in scan times that are suitable for clinical settings.
- 650 _2
- $a lidé $7 D006801
- 650 _2
- $a mužské pohlaví $7 D008297
- 650 _2
- $a ženské pohlaví $7 D005260
- 650 12
- $a magnetická rezonanční tomografie $x metody $7 D008279
- 650 12
- $a mozek $x diagnostické zobrazování $7 D001921
- 650 _2
- $a lidé středního věku $7 D008875
- 650 12
- $a poměr signál - šum $7 D059629
- 650 _2
- $a dospělí $7 D000328
- 650 _2
- $a algoritmy $7 D000465
- 650 _2
- $a mapování mozku $7 D001931
- 650 _2
- $a analýza hlavních komponent $7 D025341
- 650 _2
- $a rotace $7 D012399
- 650 _2
- $a senioři $7 D000368
- 655 _2
- $a časopisecké články $7 D016428
- 700 1_
- $a Canna, Antonietta $u Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA $u Montreal Neurological Institute and Hospital, the Neuro, McGill University, Montréal, Quebec, Canada
- 700 1_
- $a Moeller, Steen $u Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA
- 700 1_
- $a Akcakaya, Mehmet $u Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA $u Electrical and Computer Engineering, University of Minnesota, Minneapolis, Minnesota, USA
- 700 1_
- $a Metzger, Gregory J $u Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA
- 700 1_
- $a Filip, Pavel $u Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA $u Department of Neurology, First Faculty of Medicine and General University Hospital, Charles University, Prague, Czech Republic $1 https://orcid.org/0000000156565164 $7 xx0247515
- 700 1_
- $a Eberly, Lynn E $u Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA $u Division of Biostatistics, School of Public Health, University of Minnesota, Minneapolis, Minnesota, USA
- 700 1_
- $a Michaeli, Shalom $u Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA
- 700 1_
- $a Mangia, Silvia $u Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA $1 https://orcid.org/0000000163414516
- 773 0_
- $w MED00003529 $t NMR in biomedicine $x 1099-1492 $g Roč. 37, č. 12 (2024), s. e5228
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/39169274 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y - $z 0
- 990 __
- $a 20250121 $b ABA008
- 991 __
- $a 20250206104229 $b ABA008
- 999 __
- $a ok $b bmc $g 2263200 $s 1239307
- BAS __
- $a 3
- BAS __
- $a PreBMC-MEDLINE
- BMC __
- $a 2024 $b 37 $c 12 $d e5228 $e 20240821 $i 1099-1492 $m NMR in biomedicine $n NMR Biomed $x MED00003529
- GRA __
- $a P41 EB027061 $p NIBIB NIH HHS $2 United States
- GRA __
- $a R01 EB032830 $p NIBIB NIH HHS $2 United States
- GRA __
- $a R01 EB032830 $p NIH HHS $2 United States
- GRA __
- $a P41 EB027061 $p NIH HHS $2 United States
- LZP __
- $a Pubmed-20250121