PVI With CF-Sensing Large-Tip Focal PFA Catheter With 3D Mapping for Paroxysmal AF: Omny-IRE 3-Month Results

M. Duytschaever, M. Grimaldi, T. De Potter, A. Verma, L. Macle, J. Kautzner, D. Linz, A. Anic, H. Van Herendael, G. Rackauskas, P. Neuzil, J. Chun, B. Schmidt, S. Knecht, A. Almorad, B. Berte, VY. Reddy, J. Vijgen

. 2025 ; 11 (8) : 1769-1782. [pub] 20250425

Jazyk angličtina Země Spojené státy americké

Typ dokumentu klinické zkoušky, časopisecké články, multicentrická studie

Perzistentní odkaz   https://www.medvik.cz/link/bmc25022222

BACKGROUND: Omny-IRE (A Study For Treatment of Paroxysmal Atrial Fibrillation [PAF] With the OMNYPULSE Catheter and the TRUPULSE Generator) evaluated safety and effectiveness of a novel large-tip focal, multielectrode, contact force-sensing, pulsed field ablation catheter with electroanatomic mapping integration. OBJECTIVES: This study sought to assess 3-month safety and effectiveness of the platform for treating symptomatic paroxysmal atrial fibrillation. METHODS: Pulmonary vein isolation (PVI) was performed using the OMNYPULSE Platform. Primary effectiveness was adenosine/isoproterenol-proof entrance block. Primary safety was occurrence of primary adverse events. Prespecified patient subsets underwent systematic brain imaging, esophageal endoscopy, cardiac computed tomography/magnetic resonance angiogram, and mandatory 3-month remapping for PVI durability assessment. RESULTS: Of 188 patients enrolled, 136 were included in the per-protocol analysis. Primary effectiveness was 100% (136 of 136). Median (Q1-Q3) procedure, left atrial dwell, total ablation, and total fluoroscopy times were 105.5 (91.0-124.0), 70.0 (56.0-81.5), 46.9 (37.1-58.8), and 5.0 (3.1-9.8) minutes, respectively. The primary adverse event rate was 3.0% (4 of 135 patients with 3-month follow-up; 3 major vascular access complications, 1 pericarditis). Brain imaging (n = 30) revealed 1 patient (3.3%) with an asymptomatic silent cerebral event at discharge, which resolved at 1 month without neurological change. No esophageal injury was observed. Computed tomography/magnetic resonance angiogram imaging (n = 24) showed no incidences of pulmonary vein narrowing >70%. During remapping, PVI was durable in 84.5% (98 of 116) of veins and 62.1% (18 of 29) of patients. With an optimized workflow, PVI durability improved to 89.3% (75 of 84) and 71.4% (15 of 21) of veins and patients, respectively. CONCLUSIONS: The force-sensing, large-focal pulsed field ablation catheter with 3-dimensional electroanatomic mapping integration showed 100% acute success with a promising safety profile for treating paroxysmal atrial fibrillation. Prespecified remapping showed good PVI durability. (A Study For Treatment of Paroxysmal Atrial Fibrillation [PAF] With the OMNYPULSE Catheter and the TRUPULSE Generator; NCT05971693).

Citace poskytuje Crossref.org

000      
00000naa a2200000 a 4500
001      
bmc25022222
003      
CZ-PrNML
005      
20251023080147.0
007      
ta
008      
251014s2025 xxu f 000 0|eng||
009      
AR
024    7_
$a 10.1016/j.jacep.2025.04.008 $2 doi
035    __
$a (PubMed)40340298
040    __
$a ABA008 $b cze $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Duytschaever, Mattias $u Department of Cardiology, AZ Sint-Jan Hospital, Bruges, Belgium. Electronic address: Mattias.duytschaever@azsintjan.be
245    10
$a PVI With CF-Sensing Large-Tip Focal PFA Catheter With 3D Mapping for Paroxysmal AF: Omny-IRE 3-Month Results / $c M. Duytschaever, M. Grimaldi, T. De Potter, A. Verma, L. Macle, J. Kautzner, D. Linz, A. Anic, H. Van Herendael, G. Rackauskas, P. Neuzil, J. Chun, B. Schmidt, S. Knecht, A. Almorad, B. Berte, VY. Reddy, J. Vijgen
520    9_
$a BACKGROUND: Omny-IRE (A Study For Treatment of Paroxysmal Atrial Fibrillation [PAF] With the OMNYPULSE Catheter and the TRUPULSE Generator) evaluated safety and effectiveness of a novel large-tip focal, multielectrode, contact force-sensing, pulsed field ablation catheter with electroanatomic mapping integration. OBJECTIVES: This study sought to assess 3-month safety and effectiveness of the platform for treating symptomatic paroxysmal atrial fibrillation. METHODS: Pulmonary vein isolation (PVI) was performed using the OMNYPULSE Platform. Primary effectiveness was adenosine/isoproterenol-proof entrance block. Primary safety was occurrence of primary adverse events. Prespecified patient subsets underwent systematic brain imaging, esophageal endoscopy, cardiac computed tomography/magnetic resonance angiogram, and mandatory 3-month remapping for PVI durability assessment. RESULTS: Of 188 patients enrolled, 136 were included in the per-protocol analysis. Primary effectiveness was 100% (136 of 136). Median (Q1-Q3) procedure, left atrial dwell, total ablation, and total fluoroscopy times were 105.5 (91.0-124.0), 70.0 (56.0-81.5), 46.9 (37.1-58.8), and 5.0 (3.1-9.8) minutes, respectively. The primary adverse event rate was 3.0% (4 of 135 patients with 3-month follow-up; 3 major vascular access complications, 1 pericarditis). Brain imaging (n = 30) revealed 1 patient (3.3%) with an asymptomatic silent cerebral event at discharge, which resolved at 1 month without neurological change. No esophageal injury was observed. Computed tomography/magnetic resonance angiogram imaging (n = 24) showed no incidences of pulmonary vein narrowing >70%. During remapping, PVI was durable in 84.5% (98 of 116) of veins and 62.1% (18 of 29) of patients. With an optimized workflow, PVI durability improved to 89.3% (75 of 84) and 71.4% (15 of 21) of veins and patients, respectively. CONCLUSIONS: The force-sensing, large-focal pulsed field ablation catheter with 3-dimensional electroanatomic mapping integration showed 100% acute success with a promising safety profile for treating paroxysmal atrial fibrillation. Prespecified remapping showed good PVI durability. (A Study For Treatment of Paroxysmal Atrial Fibrillation [PAF] With the OMNYPULSE Catheter and the TRUPULSE Generator; NCT05971693).
650    _2
$a senioři $7 D000368
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a lidé $7 D006801
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    12
$a fibrilace síní $x chirurgie $x diagnostické zobrazování $7 D001281
650    12
$a katetrizační ablace $x metody $x přístrojové vybavení $x škodlivé účinky $7 D017115
650    _2
$a zobrazování trojrozměrné $x metody $7 D021621
650    12
$a venae pulmonales $x chirurgie $x diagnostické zobrazování $7 D011667
650    _2
$a výsledek terapie $7 D016896
655    _2
$a klinické zkoušky $7 D016430
655    _2
$a časopisecké články $7 D016428
655    _2
$a multicentrická studie $7 D016448
700    1_
$a Grimaldi, Massimo $u Ospedale Generale Regionale "F. Miulli" UOC Cardiologia, Acquaviva delle Fonti, Bari, Italy
700    1_
$a De Potter, Tom $u AZORG, Cardiovascular Center, Aalst, Belgium
700    1_
$a Verma, Atul $u McGill University Health Centre, McGill University, Montreal, Quebec, Canada
700    1_
$a Macle, Laurent $u Montreal Heart Institute, Department of Medicine, Université de Montréal, Montreal, Quebec, Canada
700    1_
$a Kautzner, Josef $u Department of Cardiology, Institute for Clinical and Experimental Medicine, Prague, Czech Republic
700    1_
$a Linz, Dominik $u Department of Cardiology, Maastricht University Medical Centre and Cardiovascular Research Institute Maastricht, Maastricht, the Netherlands
700    1_
$a Anic, Ante $u University Hospital Center Split, Split, Croatia
700    1_
$a Van Herendael, Hugo $u Ziekenhuis Oost Limburg, Genk, Belgium
700    1_
$a Rackauskas, Gediminas $u Centre for Cardiology & Angiology, Department of Cardiovascular Diseases, Vilnius University, Vilnius, Lithuania
700    1_
$a Neuzil, Petr $u Department of Cardiology, Na Homolce Hospital, Prague, Czech Republic
700    1_
$a Chun, Julian $u Cardioangiologisches Centrum Bethanien (CCB), Medizinische Klinik III, Agaplesion Markus Krankenhaus, Frankfurt am Main, Germany
700    1_
$a Schmidt, Boris $u Cardioangiologisches Centrum Bethanien (CCB), Medizinische Klinik III, Agaplesion Markus Krankenhaus, Frankfurt am Main, Germany
700    1_
$a Knecht, Sebastien $u Department of Cardiology, AZ Sint-Jan Hospital, Bruges, Belgium
700    1_
$a Almorad, Alexandre $u Heart Rhythm Management Centre, Postgraduate Program in Cardiac Electrophysiology and Pacing, Universitair Ziekenhuis Brussel-Vrije Universiteit Brussel, European Reference Networks Guard-Heart, Brussels, Belgium
700    1_
$a Berte, Benjamin $u Hirslanden St Anna, Lucerne, Switzerland
700    1_
$a Reddy, Vivek Y $u Helmsley Electrophysiology Center, Mount Sinai Fuster Heart Hospital, New York, New York, USA
700    1_
$a Vijgen, Johan $u Cardiology Department, Jessa Hospitals, Hasselt, Belgium
773    0_
$w MED00193518 $t JACC. Clinical electrophysiology $x 2405-5018 $g Roč. 11, č. 8 (2025), s. 1769-1782
856    41
$u https://pubmed.ncbi.nlm.nih.gov/40340298 $y Pubmed
910    __
$a ABA008 $b sig $c sign $y - $z 0
990    __
$a 20251014 $b ABA008
991    __
$a 20251023080152 $b ABA008
999    __
$a ok $b bmc $g 2417184 $s 1260385
BAS    __
$a 3
BAS    __
$a PreBMC-MEDLINE
BMC    __
$a 2025 $b 11 $c 8 $d 1769-1782 $e 20250425 $i 2405-5018 $m JACC. Clinical electrophysiology $n JACC Clin Electrophysiol $x MED00193518
LZP    __
$a Pubmed-20251014

Najít záznam

Citační ukazatele

Pouze přihlášení uživatelé

Možnosti archivace

Nahrávání dat ...