Slow fluorescent indicators of membrane potential: a survey of different approaches to probe response analysis

. 1996 Apr ; 33 (2) : 101-24.

Jazyk angličtina Země Švýcarsko Médium print

Typ dokumentu časopisecké články, práce podpořená grantem, přehledy

Perzistentní odkaz   https://www.medvik.cz/link/pmid08691353

Basic tenets related to the use of three main classes of potentiometric redistribution fluorescent dyes (carbocyanines, oxonols, and rhodamines) are discussed in detail. They include the structure/function relationship, formation of nonfluorescent (H-type) and fluorescent (J-type) dimers and higher aggregates, probe partitioning between membranes and medium and binding to membranes and intracellular components (with attendant changes in absorption and emission spectra, fluorescence quantum yield and lifetime). The crucial importance of suitable probe-to-cell concentration ratio and selection of optimum monitored fluorescence wavelength is illustrated in schematic diagrams and possible artifacts or puzzling results stemming from faulty experimental protocol are pointed out. Special attention is paid to procedures used for probe-response calibration (potential clamping by potassium in the presence of valinomycin, use of gramicidin D in combination with N-methylglucamine, activation of Ca-dependent K-channels by A23187, the null-point technique). Among other problems treated are dye toxicity, interaction with mitochondria and other organelles, and possible effects of intracellular pH and the quantity of cytosolic proteins and/or RNA on probe response. Individual techniques using redistribution dyes (fluorescence measurements in cuvettes, flow cytometry and microfluorimetry of individual cells including fluorescence confocal microscopy) are discussed in terms of reliability, limitations and drawbacks, and selection of suitable probes. Up-to-date examples of application of slow dyes illustrate the broad range of problems in which these probes can be used.

Citace poskytuje Crossref.org

Nejnovějších 20 citací...

Zobrazit více v
Medvik | PubMed

Monitoring of real changes of plasma membrane potential by diS-C(3)(3) fluorescence in yeast cell suspensions

. 2012 Oct ; 44 (5) : 559-69. [epub] 20120719

Monitoring of the proton electrochemical gradient in reconstituted vesicles: quantitative measurements of both transmembrane potential and intravesicular pH by ratiometric fluorescent probes

. 2007 Mar ; 17 (2) : 201-13. [epub] 20070206

Diminished synthesis of subunit a (ATP6) and altered function of ATP synthase and cytochrome c oxidase due to the mtDNA 2 bp microdeletion of TA at positions 9205 and 9206

. 2004 Nov 01 ; 383 (Pt. 3) : 561-71.

Use of synchronously excited fluorescence to assess the accumulation of membrane potential probes in yeast cells

. 2000 ; 45 (3) : 225-9.

Measurement of membrane potential in Saccharomyces cerevisiae by the electrochromic probe di-4-ANEPPS: effect of intracellular probe distribution

. 1997 ; 42 (5) : 451-6.

Three fluorescent probes for the flow-cytometric assessment of membrane potential in Saccharomyces cerevisiae

. 1996 ; 41 (3) : 237-42.

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...