Pharmacokinetics and distribution of 125I-PLA-b-PEO block copolymers in rats
Jazyk angličtina Země Velká Británie, Anglie Médium print
Typ dokumentu časopisecké články, práce podpořená grantem
PubMed
12760566
DOI
10.1081/pdt-120018484
Knihovny.cz E-zdroje
- MeSH
- chemické jevy MeSH
- fyzikální chemie MeSH
- gelová chromatografie MeSH
- izotopové značení MeSH
- kopolymer kyseliny glykolové a mléčné MeSH
- krysa rodu Rattus MeSH
- kyselina mléčná chemie MeSH
- kyselina polyglykolová chemie MeSH
- laktáty farmakokinetika MeSH
- magnetická rezonanční spektroskopie MeSH
- micely MeSH
- molekulová hmotnost MeSH
- nosiče léků farmakokinetika MeSH
- poločas MeSH
- polyethylenglykoly farmakokinetika MeSH
- polymery chemie farmakokinetika MeSH
- potkani Wistar MeSH
- tkáňová distribuce MeSH
- zánět metabolismus MeSH
- zvířata MeSH
- Check Tag
- krysa rodu Rattus MeSH
- mužské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Názvy látek
- kopolymer kyseliny glykolové a mléčné MeSH
- kyselina mléčná MeSH
- kyselina polyglykolová MeSH
- laktáty MeSH
- micely MeSH
- nosiče léků MeSH
- polyethylene oxide-polylactic acid block copolymer MeSH Prohlížeč
- polyethylenglykoly MeSH
- polymery MeSH
The PLA-b-PEO block copolymers were studied as potential carriers for anti-inflammatory and anticancer drugs. The copolymers were labeled with 125I, and their micelles in physiological saline were prepared by dialysis. Copolymer 1, with Mw = 12,360 (PLA/PEO = 7000/5000), formed particles of about 300 nm in diameter (Rh was 150 nm), whereas copolymer 2, with Mw = 20,470 (6000/14,000), made up micelles of about 72 nm in diameter (Rh was 35.8 nm). Their pharmacokinetic and biodistribution profiles were compared in normal rats and rats with carrageenan-induced inflammation after intravenous application of about 5 mg/kg of each copolymer. Copolymer 2, forming smaller particles, showed longer distribution and elimination half-lives. Both copolymers under study exhibited significantly higher uptake by inflammatory tissue compared with noninflammatory one. The study indicates that PLA-b-PEO copolymers, having different molecular weight of the chains, have similar biological behavior in most organs and tissues. Differences in the uptake by some organs (mainly kidney and bowels) and in activity level in blood at later time intervals were found. Significantly different clearance values are due to different ratios of hydrophobic and hydrophilic chains of the copolymers.
Citace poskytuje Crossref.org