Serum level of sCD163, a soluble receptor for hemoglobin, is influenced by cardiac surgery
Jazyk angličtina Země Anglie, Velká Británie Médium print-electronic
Typ dokumentu časopisecké články
PubMed
19808746
DOI
10.1177/0267659109348723
PII: 0267659109348723
Knihovny.cz E-zdroje
- MeSH
- antigeny diferenciační myelomonocytární krev MeSH
- CD antigeny krev MeSH
- haptoglobiny metabolismus MeSH
- hemoglobiny metabolismus MeSH
- kardiopulmonální bypass škodlivé účinky MeSH
- koronární bypass škodlivé účinky MeSH
- lidé středního věku MeSH
- lidé MeSH
- receptory buněčného povrchu krev MeSH
- senioři MeSH
- zánět krev etiologie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- antigeny diferenciační myelomonocytární MeSH
- CD antigeny MeSH
- CD163 Antigen MeSH
- haptoglobin-hemoglobin complex MeSH Prohlížeč
- haptoglobiny MeSH
- hemoglobiny MeSH
- receptory buněčného povrchu MeSH
BACKGROUND: The scavenger receptor for complexes hemoglobin-haptoglobin (CD163), which is expressed on monocytes/ macrophages, is shed to the body fluids in a soluble form (sCD163). OBJECTIVES: To evaluate the dynamics of sCD163 in the blood of patients undergoing cardiac surgery. PATIENTS AND METHODS: Sixty-one adult patients who underwent coronary artery bypass grafting (CABG) were enrolled in the study. They were assigned to undergo CABG using either cardiopulmonary bypass (CPB), "on-pump", (22 patients), modified CPB, mini "on-pump", (17 patients) or without CPB, "off-pump", (22 patients) surgery. Serum levels of sCD163 in venous blood samples taken before and after surgery, and during an early postoperative period, were evaluated by Macro 163(TM) diagnostic kit (IQ Products, Groningen, NL). RESULTS: Compared to the preoperative levels ("on-pump"; 344 ng/mL, "off-pump"; 314.5 ng/mL, mini-invasive "on-pump"; 336.5 ng/mL) serum levels were elevated at the finish of surgery, reaching maximum at the 1(st) postoperative day ("onpump"; 658 ng/mL; p<0.05, "off-pump"; 810.5 ng/mL; p<0.01; mini-invasive "on-pump"; 663 ng/mL; non-significant).No significant differences regarding the serum levels of sCD163 between different surgical approaches were found. CONCLUSION: Serum level of sCD163 scavenger molecule for hemoglobin is elevated at the end of surgery and at the 1(st) postoperative day, being little influenced by cardiopulmonary bypass.
Citace poskytuje Crossref.org