Production and analytical characterization of neopterin immunoreagents for biosensor developments
Jazyk angličtina Země Německo Médium print-electronic
Typ dokumentu hodnotící studie, časopisecké články, práce podpořená grantem
- MeSH
- biosenzitivní techniky metody MeSH
- ELISA metody MeSH
- hapteny chemie imunologie MeSH
- králíci MeSH
- lidé MeSH
- monoklonální protilátky imunologie MeSH
- myši inbrední BALB C MeSH
- myši MeSH
- neopterin krev imunologie MeSH
- protilátky imunologie MeSH
- renální insuficience krev MeSH
- senzitivita a specificita MeSH
- sepse krev MeSH
- specificita protilátek MeSH
- tvorba protilátek MeSH
- zvířata MeSH
- Check Tag
- králíci MeSH
- lidé MeSH
- myši MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
- práce podpořená grantem MeSH
- Názvy látek
- hapteny MeSH
- monoklonální protilátky MeSH
- neopterin MeSH
- protilátky MeSH
Neopterin is a valuable biomarker of cellular immunity associated with various pathological situations such as viral and bacterial infections, autoimmune, cardiovascular, neurodegenerative and malignant disorders. To produce specific antibodies against neopterin for a rapid multi-biomarker-based diagnosis, a novel hapten derivative was synthesized and attached to carrier proteins. The thoroughly characterized conjugates were used for immunization of BALB/c mice and rabbits. The produced monoclonal antibody reached in both direct and indirect enzyme-linked immunosorbent assay (ELISA) format LoD of 0.18 and 0.45 μg L(-1), respectively, and was a superior immunoreagent for further biosensor developments with regard to assay sensitivity and material availability. The best polyclonal antibody was somewhat more sensitive in direct ELISA with LoD of 0.05 μg L(-1). The optimized ELISA method was evaluated with blood samples collected from patients with renal insufficiency, patients with sepsis, patients without confirmed clinical diagnosis, and healthy volunteers. In plasma samples, neopterin concentrations ranging from 3.2 to 103 μg L(-1) could be determined with the monoclonal ELISA whereas twofold lower results were obtained with the polyclonal ELISA. A satisfactory correlation of results was found between the polyclonal ELISA and IBL Neopterin ELISA kit within the concentration range 0.5-16 μg L(-1) (R = 0.874; n = 40), and slightly lower correlation was found for monoclonal-based ELISA (R = 0.819; n = 40). These data show that the generated antibodies may be used as functional analytical reagents for the integration into multianalyte biochip detection systems.