Implantable intravascular defibrillator: defibrillation thresholds of an intravascular cardioverter-defibrillator compared with those of a conventional ICD in humans
Jazyk angličtina Země Spojené státy americké Médium print-electronic
Typ dokumentu srovnávací studie, časopisecké články, práce podpořená grantem
PubMed
24144885
DOI
10.1016/j.hrthm.2013.10.035
PII: S1547-5271(13)01209-5
Knihovny.cz E-zdroje
- Klíčová slova
- BCV, DFT, Defibrillation threshold, ICD, IVC, Implantable cardioverter-defibrillator, Intravascular defibrillator, PICD, RV, SVC, VF, brachiocephalic vein, defibrillation threshold, implantable cardioverter-defibrillator, inferior vena cava, percutaneous intravascular cardioverter-defibrillator, right ventricle/ventricular, superior vena cava, ventricular fibrillation,
- MeSH
- defibrilátory implantabilní * MeSH
- design vybavení MeSH
- kardiomyopatie terapie MeSH
- lidé středního věku MeSH
- lidé MeSH
- senioři MeSH
- srdeční komory MeSH
- tepový objem MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
BACKGROUND: A percutaneous intravascular cardioverter-defibrillator (PICD) has been developed with a right ventricular (RV) single-coil lead and titanium electrodes in the superior vena cava (SVC)-brachiocephalic vein (BCV) region and the inferior vena cava (IVC). OBJECTIVE: To compare defibrillation thresholds (DFTs) of the PICD with those of a conventional ICD in humans. METHODS: Ten patients with ischemic cardiomyopathy and ejection fraction ≤35% were randomized to initial testing with either PICD or conventional ICD. A standard dual-coil lead was positioned in the RV apex. If randomized to PICD, the device was placed into the vasculature such that 1 titanium electrode was positioned in the SVC-BCV region and the second in the IVC. For PICD DFTs, the RV coil of the conventional ICD lead was connected to the PICD mandrel [shock vector: RV (+) to SVC-BCV (-) + IVC (-)]. When testing the conventional ICD, a subcutaneous pocket was formed in the left pectoralis region and the ICD was connected to the lead system and positioned in the pocket [shock vector: RV (+) to SVC (-) + active can (-)]. Each device was removed before testing with the other. A step-down binary search protocol determined the DFT, with the initial shock being 9 J. RESULTS: The mean PICD DFT was 7.6 ± 3.3 J, and the conventional ICD system demonstrated a mean DFT of 9.5 ± 4.7 J (N = 10; paired t test, P = .28). CONCLUSION: The intravascular defibrillator has DFTs similar to those of commercially available ICDs.
Heart Center Semmelweis University Budapest Hungary
Hospital Na Homolce Prague Czech Republic
InnerPulse Research Triangle Park North Carolina
John Paul 2 Hospital Jagiellonian University Krakow Poland