BACKGROUND: A percutaneous intravascular cardioverter-defibrillator (PICD) has been developed with a right ventricular (RV) single-coil lead and titanium electrodes in the superior vena cava (SVC)-brachiocephalic vein (BCV) region and the inferior vena cava (IVC). OBJECTIVE: To compare defibrillation thresholds (DFTs) of the PICD with those of a conventional ICD in humans. METHODS: Ten patients with ischemic cardiomyopathy and ejection fraction ≤35% were randomized to initial testing with either PICD or conventional ICD. A standard dual-coil lead was positioned in the RV apex. If randomized to PICD, the device was placed into the vasculature such that 1 titanium electrode was positioned in the SVC-BCV region and the second in the IVC. For PICD DFTs, the RV coil of the conventional ICD lead was connected to the PICD mandrel [shock vector: RV (+) to SVC-BCV (-) + IVC (-)]. When testing the conventional ICD, a subcutaneous pocket was formed in the left pectoralis region and the ICD was connected to the lead system and positioned in the pocket [shock vector: RV (+) to SVC (-) + active can (-)]. Each device was removed before testing with the other. A step-down binary search protocol determined the DFT, with the initial shock being 9 J. RESULTS: The mean PICD DFT was 7.6 ± 3.3 J, and the conventional ICD system demonstrated a mean DFT of 9.5 ± 4.7 J (N = 10; paired t test, P = .28). CONCLUSION: The intravascular defibrillator has DFTs similar to those of commercially available ICDs.
- MeSH
- defibrilátory implantabilní * MeSH
- design vybavení MeSH
- kardiomyopatie terapie MeSH
- lidé středního věku MeSH
- lidé MeSH
- senioři MeSH
- srdeční komory MeSH
- tepový objem MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
AIMS: The totally subcutaneous implantable-defibrillator (S-ICD) is a new alternative to the conventional transvenous ICD system to minimize intravascular lead complications. There are limited data describing the long-term performance of the S-ICD. This paper presents the first large international patient population collected as part of the EFFORTLESS S-ICD Registry. METHODS AND RESULTS: The EFFORTLESS S-ICD Registry is a non-randomized, standard of care, multicentre Registry designed to collect long-term, system-related, clinical, and patient reported outcome data from S-ICD implanted patients since June 2009. Follow-up data are systematically collected over 60-month post-implant including Quality of Life. The study population of 472 patients of which 241 (51%) were enrolled prospectively has a mean follow-up duration of 558 days (range 13-1342 days, median 498 days), 72% male, mean age of 49 ± 18 years (range 9-88 years), 42% mean left ventricular ejection fraction. Complication-free rates were 97 and 94%, at 30 and 360 days, respectively. Three hundred and seventeen spontaneous episodes were recorded in 85 patients during the follow-up period. Of these episodes, 169 (53%) received therapy, 93 being for Ventricular Tachycardia/Fibrillation (VT/VF). One patient died of recurrent VF and severe bradycardia. Regarding discrete VT/VF episodes, first shock conversion efficacy was 88% with 100% overall successful clinical conversion after a maximum of five shocks. The 360-day inappropriate shock rate was 7% with the vast majority occurring for oversensing (62/73 episodes), primarily of cardiac signals (94% of oversensed episodes). CONCLUSION: The first large cohort of real-world data from an International patient S-ICD population demonstrates appropriate system performance with clinical event rates and inappropriate shock rates comparable with those reported for conventional ICDs. Clinical trial registration URL: http://www.clinicaltrials.gov. Unique identifier NCT01085435.
- MeSH
- čas zasáhnout při rozvinutí nemoci MeSH
- defibrilátory implantabilní škodlivé účinky normy statistika a číselné údaje MeSH
- dítě MeSH
- dospělí MeSH
- implantace protézy metody MeSH
- kvalita života MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- prospektivní studie MeSH
- registrace MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- srdeční arytmie terapie MeSH
- výsledek terapie MeSH
- Check Tag
- dítě MeSH
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladiství MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
- multicentrická studie MeSH
- pozorovací studie MeSH
- práce podpořená grantem MeSH
BACKGROUND: Alcohol septal ablation (ASA) is a catheter-based intervention that has been used as an alternative to surgical myectomy in highly symptomatic patients with hypertrophic obstructive cardiomyopathy (HOCM). METHODS: This retrospective study was designed to evaluate the incidence of major complications in the mid-term follow-up of low-dose (1-2.5 ml of ethanol), echo-guided alcohol septal ablation. RESULTS: A total of 101 consecutive patients (56 +/- 15 years) with highly symptomatic HOCM were enrolled. At 6 months, there was a significant decrease in resting outflow gradient accompanied by reduction in basal septal diameter and improvement in symptoms (P < 0.01). Two patients (2%) experienced procedural ventricular tachycardias terminated by electrical cardioversion. A total of 87 patients (86%) underwent an uneventful postprocedural hospital stay. The postprocedural complete heart block occurred in 10 patients (10%), and subsequent permanent pacemaker was implanted in four cases (4%). Sustained ventricular arrhythmias requiring electrical cardioversion occurred in four patients (4%) within postprocedural hospital stay. Subsequently, ICD was not implanted in any of these cases. The patients were repeatedly examined by Holter ECG monitoring, and in the mid-term follow-up (6-50 months), they stayed asymptomatic and without any ventricular arrhythmias. CONCLUSION: This study demonstrates the same early incidence of complete heart block requiring permanent pacemaker implantation (4%) and sustained ventricular arrhythmias following low-dose, echo-guided ASA.
- MeSH
- časové faktory MeSH
- dospělí MeSH
- elektrická defibrilace MeSH
- elektrokardiografie ambulantní MeSH
- ethanol aplikace a dávkování škodlivé účinky MeSH
- hypertrofická kardiomyopatie terapie ultrasonografie MeSH
- injekce MeSH
- intervenční ultrasonografie MeSH
- kardiostimulace umělá MeSH
- komorová tachykardie diagnóza etiologie terapie MeSH
- lidé středního věku MeSH
- lidé MeSH
- retrospektivní studie MeSH
- senioři MeSH
- srdeční blokáda diagnóza etiologie terapie MeSH
- srdeční katetrizace škodlivé účinky MeSH
- výsledek terapie MeSH
- vztah mezi dávkou a účinkem léčiva MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
BACKGROUND: Morbidity and mortality outcomes for patients admitted for acute decompensated heart failure are poor and have not significantly changed in decades. Current therapies are focused on symptom relief by addressing signs and symptoms of congestion. The objective of this study was to test a novel neuromodulation therapy of stimulation of epicardial cardiac nerves passing along the posterior surface of the right pulmonary artery. METHODS: Fifteen subjects admitted for defibrillator implantation and ejection fraction ≤35% on standard heart failure medications were enrolled. Through femoral arterial access, high fidelity pressure catheters were placed in the left ventricle and aortic root. After electro anatomic rendering of the pulmonary artery and branches, either a circular or basket electrophysiology catheter was placed in the right pulmonary artery to allow electrical intravascular stimulation at 20 Hz, 4 ms pulse width, and ≤20 mA. Changes in maximum positive dP/dt (dP/dtMax) indicated changes in ventricular contractility. RESULTS: Of 15 enrolled subjects, 5 were not studied due to equipment failure or abnormal pulmonary arterial anatomy. In the remaining subjects, dP/dtMax increased significantly by 22.6%. There was also a significant increase in maximum negative dP/dt (dP/dtMin), mean arterial pressure, systolic pressure, diastolic pressure, and left ventricular systolic pressure. There was no significant change in heart rate or left ventricular diastolic pressure. CONCLUSIONS: In this first-in-human study, we demonstrated that in humans with stable heart failure, left ventricular contractility could be accentuated without an increase in heart rate or left ventricular filling pressures. This benign increase in contractility may benefit patients admitted for acute decompensated heart failure.
- MeSH
- autonomní nervový systém patofyziologie MeSH
- časové faktory MeSH
- funkce levé komory srdeční * MeSH
- kardiostimulace umělá škodlivé účinky metody MeSH
- kontrakce myokardu * MeSH
- lidé středního věku MeSH
- lidé MeSH
- obnova funkce MeSH
- ověření koncepční studie MeSH
- senioři MeSH
- srdce inervace MeSH
- srdeční selhání diagnóza patofyziologie terapie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
... BONOW -- 19 Cardiac Catheterization, 348 -- JOERG HERRMANN -- 20 Coronary Angiography and Intravascular ... ... ABRAHAM -- Guidelines: Cardiac Resynchronization and Implantable Cardioverter-Defibrillators in Heart ... ... ZIPES -- 41 Pacemakers and Implantable Cardioverter-Defibrillators, 780 -- CHARLES D. ... ... ZIPES -- Guidelines: Cardiac Pacemakers and Cardioverter-Defibrillators, 800 -- CHARLES D. ...
Eleventh edition 2 svazky (xxviii, 1944, DI-4, I-64 stran) : ilustrace ; 29 cm
- Konspekt
- Patologie. Klinická medicína
- NLK Obory
- kardiologie
- NLK Publikační typ
- kolektivní monografie
... Questions and answers, 317 -- References, 319 -- - Permanent Pacemaker and Implantable Cardioverter Defibrillator ... ... Effect on pacing thresholds and defibrillation thresholds, 365 -- Further reading, 365 -- PART 6. ... ... Intravascular ultrasound (IVUS), 741 -- I. Image basics, 741 il. Plaque types, 744 -- III. ...
xxiv, 801 stran : ilustrace ; 28 cm
- MeSH
- kardiovaskulární nemoci MeSH
- nemoci srdce MeSH
- Publikační typ
- monografie MeSH
- Konspekt
- Patologie. Klinická medicína
- NLK Obory
- kardiologie