Prospective Validation of the 0/1-h Algorithm for Early Diagnosis of Myocardial Infarction
Jazyk angličtina Země Spojené státy americké Médium print
Typ dokumentu časopisecké články, multicentrická studie
PubMed
30071991
DOI
10.1016/j.jacc.2018.05.040
PII: S0735-1097(18)35057-5
Knihovny.cz E-zdroje
- Klíčová slova
- diagnosis of myocardial infarction, diagnostic algorithms, myocardial infarction, rule-in, rule-out, troponin,
- MeSH
- algoritmy * MeSH
- bolesti na hrudi diagnóza epidemiologie patofyziologie MeSH
- časná diagnóza MeSH
- infarkt myokardu diagnóza epidemiologie patofyziologie MeSH
- internacionalita * MeSH
- lidé středního věku MeSH
- lidé MeSH
- následné studie MeSH
- prediktivní hodnota testů MeSH
- prospektivní studie MeSH
- reprodukovatelnost výsledků MeSH
- senioři MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
BACKGROUND: The safety of the European Society of Cardiology (ESC) 0/1-h algorithm for rapid rule-out and rule-in of non-ST-segment elevation myocardial infarction (NSTEMI) using high-sensitivity cardiac troponin (hs-cTn) has been questioned. OBJECTIVES: This study aimed to validate the diagnostic performance of the 0/1-h algorithm in a large multicenter study. METHODS: The authors prospectively enrolled unselected patients in 6 countries presenting to the emergency department with symptoms suggestive of NSTEMI. Final diagnosis was centrally adjudicated by 2 independent cardiologists. Hs-cTnT and hs-cTnI blood concentrations were measured at presentation and after 1 h. Safety of rule-out was quantified by the negative predictive value (NPV) for NSTEMI, accuracy of rule-in by the positive predictive value (PPV), and overall efficacy by the proportion of patients triaged towards rule-out or rule-in within 1 h. RESULTS: Prevalence of NSTEMI was 17%. Among 4,368 patients with serial hs-cTnT measurements available, safety of rule-out (NPV 99.8%, 2,488 of 2,493), accuracy of rule-in (PPV 74.5%, 572 of 768), and overall efficacy were high by assigning three-fourths of patients either to rule-out (57%, 2,493 to 4,368) or rule-in (18%, 768 to 4,368). Similarly, among 3,500 patients with serial hs-cTnI measurements, safety of rule-out (NPV 99.7%, 1,528 of 1,533), accuracy of rule-in (PPV 62.3%, 498 of 800), and overall efficacy were high by assigning more than two-thirds of patients either to rule-out (44%, 1,533 of 3,500) or rule-in (23%, 800 of 3,500). Excellent safety was confirmed in multiple subgroup analyses including patients presenting early (≤3 h) after chest pain onset. CONCLUSIONS: The ESC 0/1-h algorithm using hs-cTnT and hs-cTnI is very safe and effective in triaging patients with suspected NSTEMI. (Advantageous Predictors of Acute Coronary Syndromes Evaluation [APACE]; NCT00470587; and Biomarkers in Acute Cardiac Care [BACC]; NCT02355457).
2nd Department of Cardiology Medical University of Silesia Zabrze Poland
Emergency Department Hospital Clinic Barcelona Catalonia Spain
Emergency Department Kantonsspital Baselland Liestal Switzerland
Emergency Department University Hospital Zurich Zurich Switzerland
Servicio de Urgencias Hospital Clínico San Carlos Madrid Spain
Citace poskytuje Crossref.org