Efficacy and safety of a new selective laser device to create anterior capsulotomies in cataract patients
Language English Country United States Media print-electronic
Document type Journal Article, Research Support, Non-U.S. Gov't
PubMed
30826240
DOI
10.1016/j.jcrs.2018.12.012
PII: S0886-3350(18)31009-5
Knihovny.cz E-resources
- MeSH
- Coloring Agents administration & dosage MeSH
- Capsulorhexis methods MeSH
- Adult MeSH
- Phacoemulsification * methods MeSH
- Lens Implantation, Intraocular * MeSH
- Cataract complications MeSH
- Laser Therapy adverse effects instrumentation MeSH
- Middle Aged MeSH
- Humans MeSH
- Anterior Capsule of the Lens surgery MeSH
- Prospective Studies MeSH
- Pseudophakia physiopathology MeSH
- Aged MeSH
- Trypan Blue administration & dosage MeSH
- Treatment Outcome MeSH
- Visual Acuity physiology MeSH
- Check Tag
- Adult MeSH
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
- Names of Substances
- Coloring Agents MeSH
- Trypan Blue MeSH
PURPOSE: To compare the efficacy and safety of anterior capsulotomy creation with a new selective laser device (CAPSULaser) with those of manual capsulotomies. SETTING: GEMINI Eye Clinic, Zlin, Czech Republic. DESIGN: Prospective case series. METHODS: Patients were placed in cohorts based on age and cataract grade and randomly allocated to have laser capsulotomy or manual continuous curvilinear capsulorhexis (CCC). The anterior capsule was stained with microfiltered trypan blue 0.4%. The anterior capsulotomy was created with the laser device focused on the anterior capsule through a custom patient interface lens. Intraoperative video analysis with the use of an intraocular ruler and postoperative examinations were used to assess safety and efficacy (accuracy of capsulotomy size, circularity, centration). RESULTS: No intraoperative complications occurred in the laser group or the manual group. All capsulotomies in the laser group were free-floating with no tags or tears. The mean capsulotomy diameter was 5.03 mm overall (range 4.8 to 5.2 mm, laser group; 4.4 to 5.8 mm, manual group). In the laser group, all the capsulotomies were within 0.1 mm ± 0.1 (SD) of the target. The circularity accuracy was greater than 99.0% ± 1.0%; the mean centration of the capsulotomy in relation to the intraocular lens (IOL) was 0.1 ± 0.1 mm. All parameters were statistically significant (P < .01). The IOL-capsulotomy overlap was 360 degrees in all laser cases. CONCLUSIONS: Selective laser capsulotomy using a new proprietary trypan blue formulation was safe and effective in cataract surgery. The sizing, circularity, and centration of the laser capsulotomy were more accurate than those of the manual CCC, resulting in consistent 360-degree IOL coverage.
References provided by Crossref.org