EFFECT OF MULTIPLE VARIABLES ON THE REFRACTIVE ERROR AFTER CATARACT SURGERY
Language English Country Czech Republic Media print
Document type Journal Article
PubMed
30913892
DOI
10.31348/2018/1/4-6-2018
PII: 107759
Knihovny.cz E-resources
- Keywords
- IOL calculation, Optical biometry, monofocal IOL, refractive error,
- MeSH
- Cataract Extraction * adverse effects MeSH
- Lens Implantation, Intraocular MeSH
- Cataract * MeSH
- Humans MeSH
- Lenses, Intraocular * MeSH
- Refractive Errors * etiology MeSH
- Check Tag
- Humans MeSH
- Publication type
- Journal Article MeSH
- Geographicals
- Slovakia MeSH
PURPOSE: To analyze refractive results after cataract surgery in relation to used type of monofocal intraocular lens, calculation formula, to age, gender and laterality. SETTINGS: Department of Ophthalmology, Comenius University and University hospital in Bratislava, Slovakia Methods: We analyzed 173 eyes (118 patients) after uneventful cataract surgery. We calculated prediction error (PE) and mean absolute error (MAE) of postoperative refraction. RESULTS AND CONCLUSION: We found no statistically significant differences in PE and MAE in relation to types of used IOL, calculation formulas, gender, age or laterality. Key words: Optical biometry, monofocal IOL, IOL calculation, refractive error.