• This record comes from PubMed

A simulation study of left ventricular decompression using a double lumen arterial cannula prototype during a veno-arterial extracorporeal membrane oxygenation

. 2019 Dec ; 42 (12) : 748-756. [epub] 20190627

Language English Country United States Media print-electronic

Document type Journal Article

Grant support
R01 HL139813 NHLBI NIH HHS - United States

BACKGROUND: Veno-arterial extracorporeal membrane oxygenation can be vital to support patients in severe or rapidly progressing cardiogenic shock. In cases of left ventricular distension, left ventricular decompression during veno-arterial extracorporeal membrane oxygenation may be a crucial factor influencing the patient outcome. Application of a double lumen arterial cannula for a left ventricular unloading is an alternative, straightforward method for left ventricular decompression during extracorporeal membrane oxygenation in a veno-arterial configuration. OBJECTIVES: The purpose of this article is to use a mathematical model of the human adult cardiovascular system to analyze the left ventricular function of a patient in cardiogenic shock supported by veno-arterial extracorporeal membrane oxygenation with and without the application of left ventricular unloading using a novel double lumen arterial cannula. METHODS: A lumped model of cardiovascular system hydraulics has been coupled with models of non-pulsatile veno-arterial extracorporeal membrane oxygenation, a standard venous cannula, and a drainage lumen of a double lumen arterial cannula. Cardiogenic shock has been induced by decreasing left ventricular contractility to 10% of baseline normal value. RESULTS: The simulation results indicate that applying double lumen arterial cannula during veno-arterial extracorporeal membrane oxygenation is associated with reduction of left ventricular end-systolic volume, end-diastolic volume, end-systolic pressure, and end-diastolic pressure. CONCLUSIONS: A double lumen arterial cannula is a viable alternative less invasive method for left ventricular decompression during veno-arterial extracorporeal membrane oxygenation. However, to allow for satisfactory extracorporeal membrane oxygenation flow, the cannula design has to be revisited.

See more in PubMed

Napp LC, Kuhn C, Bauersachs J. ECMO in cardiac arrest and cardiogenic shock. Herz 2017; 42: 27–44. PubMed PMC

Meani P, Gelsomino S, Natour E, et al. Modalities and Effects of Left Ventricle Unloading on Extracorporeal Life support: a Review of the Current Literature. Eur J Heart Fail 2017; 19 Suppl 2: 84–91. PubMed

Ostadal P, Mlcek M, Kruger A, et al. Increasing venoarterial extracorporeal membrane oxygenation flow negatively affects left ventricular performance in a porcine model of cardiogenic shock. J Transl Med 2015; 13: 266. PubMed PMC

Strunina S, Hozman J, Ostadal P. Relation Between Left Ventricular Unloading During Ecmo And Drainage Catheter Size Assessed By Mathematical Modeling. Acta Polytech Scand Chem Technol Ser 2017; 57: 367.

Truby LK, Takeda K, Mauro C, et al. Incidence and Implications of Left Ventricular Distention During Venoarterial Extracorporeal Membrane Oxygenation Support. ASAIO J 2017; 63: 257–265. PubMed

Alhussein M, Osten M, Horlick E, et al. Percutaneous left atrial decompression in adults with refractory cardiogenic shock supported with veno-arterial extracorporeal membrane oxygenation. J Card Surg 2017; 32: 396–401. PubMed

Strunina S, Ostadal P . Left ventricle unloading during veno-arterial extracorporeal membrane oxygenation. Current Research: Cardiology; 3, https://www.pulsus.com/scholarly-articles/left-ventricle-unloading-during-venoarterial-extracorporeal-membrane-oxygenation.html (2016).

Donker DW, Brodie D, Henriques JPS, et al. Left ventricular unloading during veno-arterial ECMO: a review of percutaneous and surgical unloading interventions. Perfusion 2018; 267659118794112. PubMed PMC

Kussmaul WG 3rd, Buchbinder M, Whitlow PL, et al. Rapid arterial hemostasis and decreased access site complications after cardiac catheterization and angioplasty: results of a randomized trial of a novel hemostatic device. J Am Coll Cardiol 1995; 25: 1685–1692. PubMed

Merrer J, De Jonghe B, Golliot F, et al. Complications of femoral and subclavian venous catheterization in critically ill patients: a randomized controlled trial. JAMA 2001; 286: 700–707. PubMed

Strunina S, Hozman J, Ostadal P. The peripheral cannulas in extracorporeal life support. Biomed Tech. Epub ahead of print 12 April 2018 DOI: 10.1515/bmt-2017-0107. PubMed DOI

Brunner M-E, Banfi C, Giraud R. Venoarterial Extracorporeal Membrane Oxygenation in Refractory Cardiogenic Shock and Cardiac Arrest In: Firstenberg MS (ed) Extracorporeal Membrane Oxygenation: Advances in Therapy. InTech, 2016.

Donker DW, Brodie D, Henriques JPS, et al. Left Ventricular Unloading During Veno-Arterial ECMO: A Simulation Study. ASAIO J 2019; 65: 11–20. PubMed PMC

Strunina S, Hozman J, Ošt’ádal P. A cannula containing a base tube with two adjacent longitudinally leading lumens. Excerpt from the database ofpatents and utility models, https://isdv.upv.cz/webapp/webapp.pts.det?xprim=10225884&lan=en (2018, accessed 20 July 2018).

Jeẑek F ECMO DLAC model demonstration. The Virtual Physiological Rat Project, http://virtualrat.org/models/ecmo-dlac-model-demonstration-0 (2019, accessed 25 April 2019).

Jeẑek F. Physiolibrarymodels. GitHub, https://github.com/filip-jezek/Physiolibrary.models (accessed 20 July 2017).

Mateják M, Kulhánek T, Šilar J, et al. Physiolibrary - Modelica library for Physiology. In: 10th International Modelica Conference Lund, Sweden, 2014.

Mateják M Physiology in Modelica. MEFANET Journal 2014; 2: 10–14.

Ježek F, Kulhánek T, Kalecký K, et al. Lumped models of the cardiovascular system of various complexity. Biocybernetics and Biomedical Engineering 2017; 37: 666–678.

Arts T, Lumens J, Kroon W, et al. Control of Whole Heart Geometry by Intramyocardial Mechano-Feedback: A Model Study. PLoS Comput Biol; 8 Epub ahead of print 2 September 2012 DOI: 10.1371/joumal.pcbi.l002369. PubMed DOI PMC

Mynard JP, Davidson MR, Penny DJ, et al. A simple, versatile valve model for use in lumped parameter and one-dimensional cardiovascular models. Int J Numer Meth Biomed Engng 2012; 28: 626–641. PubMed

Bovendeerd PHM, Borsje P, Arts T, et al. Dependence of Intramyocardial Pressure and Coronary Flow on Ventricular Loading and Contractility: A Model Study. Ann Biomed Eng 2006; 34: 1833–1845. PubMed PMC

Smith BW, Chase JG, Nokes RI, et al. Minimal haemodynamic system model including ventricular interaction and valve dynamics. Med Eng Phys 2004; 26: 131–139. PubMed

Maquet, Getinge Group. Avalon Elite Bi-Caval Dual Lumen Catheter (Datasheet). {Maquet, Getinge Group; }, https://www.getinge.com/siteassets/products-a-z/avalon-elite-bi-caval-dual-lumen-catheter/avalonelite_mcp_br_10012_en_l_screen.pdf?disclaimerAccepted=yes (Date unknown).

Maquet Getinge Group. Canules HLS Des solutions du drainage a la reinjection, https://www.maquet.com/globalassets/products/canules-hls/brochure-fr---canules-hls.pdf (2017).

Wang S, Force M, Kunselman AR, et al. Hemodynamic Evaluation of Avalon Elite Bi-Caval Dual Lumen Cannulas and Femoral Arterial Cannulas. Artif Organs 2019; 43: 41–53. PubMed

Extracorporeal Life Support Organization. ELSO Guidelines for Cardiopulmonary Extracorporeal Life Support. Version 1.4 August 2017, Extracorporeal Life Support Organization, https://www.elso.org/Portals/0/ELSO%20Guidelines%20General%20All%20ECLS%20Version%201_4.pdf (August 2017).

Tewelde SZ, Liu SS, Winters ME. Cardiogenic Shock. Cardiol Clin 2018; 36: 53–61. PubMed

Silverthom DU. Human Physiology: An Integrated Approach. Pearson Education, 2013.

Hochman JS, Magnus Ohman E. Cardiogenic Shock. John Wiley & Sons, 2009.

Broome M, Donker DW. Individualized real-time clinical decision support to monitor cardiac loading during venoarterial ECMO. J Transl Med 2016; 14: 4. PubMed PMC

Guirgis M, Kumar K, Menkis AH, et al. Minimally invasive left-heart decompression during venoarterial extracorporeal membrane oxygenation: an alternative to a percutaneous approach. Interact Cardiovasc Thorac Surg 2010; 10: 672–674. PubMed

Barbone A, Malvindi PG, Ferrara P, et al. Left ventricle unloading by percutaneous pigtail during extracorporeal membrane oxygenation. Interact Cardiovasc Thorac Surg 2011; 13: 293–295. PubMed

Rupprecht L, Florchinger B, Schopka S, et al. Cardiac decompression on extracorporeal life support: a review and discussion of the literature. ASAIO J 2013; 59: 547–553. PubMed

Hong TH, Byun JH, Yoo BH, et al. Successful Left-Heart Decompression during Extracorporeal Membrane Oxygenation in an Adult Patient by Percutaneous Transaortic Catheter Venting. Korean J Thorac Cardiovasc Surg 2015; 48: 210–213. PubMed PMC

Fumagalli R, Bombino M, Borelli M, et al. Percutaneous bridge to heart transplantation by venoarterial ECMO and transaortic left ventricular venting. Int J Artif Organs 2004; 27: 410–413. PubMed

Avalli L, Maggioni E, Sangalli F, et al. Percutaneous left-heart decompression during extracorporeal membrane oxygenation: an alternative to surgical and transeptal venting in adult patients. ASAIO J 2011; 57: 38–40. PubMed

Silar J, Polak D, Mladek A, et al. Bodylight.js - toolchain for authoring in-browser simulators. JMIR Preprints, https://preprints.jmir.org/preprint/14160 (2019, accessed 23 April 2019).

Wang S, Chin BJ, Gentile F, et al. Potential Danger of Pre-Pump Clamping on Negative Pressure-Associated Gaseous Microemboli Generation During Extracorporeal Life Support--An In Vitro Study. Artif Organs 2016; 40: 89–94. PubMed

Newest 20 citations...

See more in
Medvik | PubMed

Left ventricular unloading and the role of ECpella

. 2021 Mar ; 23 (Suppl A) : A27-A34. [epub] 20210327

Find record

Citation metrics

Loading data ...

Archiving options