Electrographic flow mapping of persistent atrial fibrillation: intra- and inter-procedure reproducibility in the absence of 'ground truth'

. 2023 Nov 02 ; 25 (11) : .

Jazyk angličtina Země Velká Británie, Anglie Médium print

Typ dokumentu časopisecké články

Perzistentní odkaz   https://www.medvik.cz/link/pmid37956309

Grantová podpora
Ablacon

AIMS: Validating mapping systems that identify atrial fibrillation (AF) sources (focal/rotational activity) is confounded by the absence of ground truth. A key concern of prior mapping technologies is spatiotemporal instability, manifesting as poor map reproducibility. Electrographic flow (EGF) employs a novel algorithm that visualizes atrial electrical wavefront propagation to identify putative AF sources. We analysed both intra- (3 min) and inter- (>3 months) procedure EGF map reproducibility. METHODS AND RESULTS: In 23 persistent AF patients, after pulmonary vein isolation (PVI), EGF maps were generated from 3 serial 1 min recordings using a 64-electrode basket mapping catheter (triplets) at right and left atrial locations. Source prevalence from map triplets was compared between recordings. Per protocol, 12 patients returned for 3-month remapping (1 non-inducible): index procedure post-PVI EGF maps were compared with initial EGF remapping at 3-month redo. Intra-procedure reproducibility: analysing 224 map triplets (111 right atrium, 113 left atrium) revealed a high degree of map consistency with minimal min-to-min shifts: 97 triplets (43%), exact match of leading sources on all 3 maps; 95 triplets (42%), leading source within 1 electrode space on 2 of 3 maps; and 32 triplets (14%), chaotic leading source pattern. Average deviation in source prevalence over 60 s was low (6.4%). Inter-procedure reproducibility: spatiotemporal stability of EGF mapping >3 months was seen in 16 of 18 (89%) sources mapped in 12 patients with (re)inducible AF. CONCLUSION: Electrographic flow mapping generates reproducible intra- and inter-procedural maps, providing rationale for randomized clinical trials targeting these putative AF sources.

Zobrazit více v PubMed

Schreiber D, Rostock T, Frohlich M, Sultan A, Servatius H, Hoffmann BAet al. . Five-year follow-up after catheter ablation of persistent atrial fibrillation using the stepwise approach and prognostic factors for success. Circ Arrhythm Electrophysiol 2015;8:308–17. PubMed

Verma A, Jiang CY, Betts TR, Chen J, Deisenhofer I, Mantovan Ret al. . Approaches to catheter ablation for persistent atrial fibrillation. N Engl J Med 2015;372:1812–22. PubMed

Haissaguerre M, Hocini M, Sanders P, Takahashi Y, Rotter M, Sacher Fet al. . Localized sources maintaining atrial fibrillation organized by prior ablation. Circulation 2006;113:616–25. PubMed

Haissaguerre M, Hocini M, Denis A, Shah AJ, Komatsu Y, Yamashita Set al. . Driver domains in persistent atrial fibrillation. Circulation 2014;130:530–8. PubMed

Hansen BJ, Zhao J, Li N, Zolotarev A, Zakharkin S, Wang Yet al. . Human atrial fibrillation drivers resolved with integrated functional and structural imaging to benefit clinical mapping. JACC Clin Electrophysiol 2018;4:1501–15. PubMed PMC

Martinez-Mateu L, Romero L, Ferrer-Albero A, Sebastian R, Rodriguez Matas JF, Jalife Jet al. . Factors affecting basket catheter detection of real and phantom rotors in the atria: a computational study. PLoS Comput Biol 2018;14:e1006017. PubMed PMC

Honarbakhsh S, Schilling RJ, Dhillon G, Ullah W, Keating E, Providencia Ret al. . A novel mapping system for panoramic mapping of the left atrium: application to detect and characterize localized sources maintaining atrial fibrillation. JACC Clin Electrophysiol 2018;4:124–34. PubMed PMC

Narayan SM, Baykaner T, Clopton P, Schricker A, Lalani GG, Krummen DEet al. . Ablation of rotor and focal sources reduces late recurrence of atrial fibrillation compared with trigger ablation alone: extended follow-up of the CONFIRM trial (Conventional Ablation for Atrial Fibrillation With or Without Focal Impulse and Rotor Modulation). J Am Coll Cardiol 2014;63:1761–8. PubMed PMC

Choudry S, Mansour M, Sundaram S, Nguyen DT, Dukkipati SR, Whang Wet al. . RADAR: a multicenter food and drug administration investigational device exemption clinical trial of persistent atrial fibrillation. Circ Arrhythm Electrophysiol 2020;13:e007825. PubMed PMC

Verma A, Sarkozy A, Skanes A, Duytschaever M, Bulava A, Urman Ret al. . Characterization and significance of localized sources identified by a novel automated algorithm during mapping of human persistent atrial fibrillation. J Cardiovasc Electrophysiol 2018;29:1480–8. PubMed

Brachmann J, Hummel JD, Wilber DJ, Sarver AE, Rapkin J, Shlomo Set al. . S-LBCT01-02 Prospective randomized comparison of rotor ablation vs conventional ablation for treatment of persistent atrial fibrillation - the REAFFIRM trial [Internet]. Heart Rhythm. 2019. https://www.abstractsonline.com/pp8/#!/5753/presentation/31210.

Spitzer SG, Miller JM, Sommer P, Szili-Torok T, Reddy VY, Nolker Get al. . Randomized evaluation of redo ablation procedures of atrial fibrillation with focal impulse and rotor modulation-guided procedures: the REDO-FIRM study. Europace 2023;25:74–82. PubMed PMC

Haines DE, Kong MH, Ruppersberg P, Haeusser P, Avitall B, Torok TSet al. . Electrographic flow mapping for atrial fibrillation: theoretical basis and preliminary observations. J Interv Card Electrophysiol 2023;66:1015–28. PubMed PMC

Bellmann B, Lin T, Ruppersberg P, Zettwitz M, Guttmann S, Tscholl Vet al. . Identification of active atrial fibrillation sources and their discrimination from passive rotors using electrographical flow mapping. Clin Res Cardiol 2018;107:1021–32. PubMed

Bellmann B, Zettwitz M, Lin T, Ruppersberg P, Guttmann S, Tscholl Vet al. . Velocity characteristics of atrial fibrillation sources determined by electrographic flow mapping before and after catheter ablation. Int J Cardiol 2019;286:56–60. PubMed

Szili-Torok T, Kis Z, Bhagwandien R, Wijchers S, Yap SC, Hoogendijk Met al. . Functional electrographic flow patterns in patients with persistent atrial fibrillation predict outcome of catheter ablation. J Cardiovasc Electrophysiol 2021;32:2148–58. PubMed PMC

Kong MH, Castellano S, Ruppersberg P, Lizama KS, Avitall B. Visualization of electrographic flow fields of increasing complexity and detection of simulated sources during spontaneously persistent AF in an animal model. Front Cardiovasc Med 2023;10:1223481. PubMed PMC

Szili-Torok T, Neuzil P, Langbein A, Petru J, Funasako M, Dinshaw Let al. . Electrographic Flow-Guided Ablation in Redo Patients with Persistent Atrial Fibrillation (FLOW-AF): design and rationale. Heart Rhythm O2 2023;4:391–400. PubMed PMC

Swerdlow M, Tamboli M, Alhusseini MI, Moosvi N, Rogers AJ, Leef Get al. . Comparing phase and electrographic flow mapping for persistent atrial fibrillation. Pacing Clin Electrophysiol 2019;42:499–507. PubMed PMC

Atienza F, Almendral J, Jalife J, Zlochiver S, Ploutz-Snyder R, Torrecilla EGet al. . Real-time dominant frequency mapping and ablation of dominant frequency sites in atrial fibrillation with left-to-right frequency gradients predicts long-term maintenance of sinus rhythm. Heart Rhythm 2009;6:33–40. PubMed PMC

Calkins H, Hindricks G, Cappato R, Kim YH, Saad EB, Aguinaga Let al. . 2017 HRS/EHRA/ECAS/APHRS/SOLAECE expert consensus statement on catheter and surgical ablation of atrial fibrillation. Heart Rhythm 2017;14:e275–444. PubMed PMC

Hansen BJ, Zhao J, Csepe TA, Moore BT, Li N, Jayne LAet al. . Atrial fibrillation driven by micro-anatomic intramural re-entry revealed by simultaneous sub-epicardial and sub-endocardial optical mapping in explanted human hearts. Eur Heart J 2015;36:2390–401. PubMed PMC

Lee S, Sahadevan J, Khrestian CM, Cakulev I, Markowitz A, Waldo AL. Simultaneous biatrial high-density (510–512 electrodes) epicardial mapping of persistent and long-standing persistent atrial fibrillation in patients: new insights into the mechanism of its maintenance. Circulation 2015;132:2108–17. PubMed PMC

Lee S, Sahadevan J, Khrestian CM, Durand DM, Waldo AL. High density mapping of atrial fibrillation during vagal nerve stimulation in the canine heart: restudying the Moe hypothesis. J Cardiovasc Electrophysiol 2013;24:328–35. PubMed

Zhao J, Hansen BJ, Wang Y, Csepe TA, Sul LV, Tang Aet al. . Three-dimensional integrated functional, structural, and computational mapping to define the structural “fingerprints” of heart-specific atrial fibrillation drivers in human heart ex vivo. J Am Heart Assoc 2017;6:e005922. PubMed PMC

Rosa G, Quintanilla JG, Salgado R, Gonzalez-Ferrer JJ, Canadas-Godoy V, Perez-Villacastin Jet al. . Mapping technologies for catheter ablation of atrial fibrillation beyond pulmonary vein isolation. Eur Cardiol 2021;16:e21. PubMed PMC

Hemam ME, Dave AS, Rodriguez-Manero M, Valderrabano M. Epiphenomenal re-entry and spurious focal activation detection by atrial fibrillation mapping algorithms. JACC Clin Electrophysiol 2021;7:923–32. PubMed PMC

Narayan SM, Krummen DE, Shivkumar K, Clopton P, Rappel WJ, Miller JM. Treatment of atrial fibrillation by the ablation of localized sources: CONFIRM (Conventional Ablation for Atrial Fibrillation With or Without Focal Impulse and Rotor Modulation) trial. J Am Coll Cardiol 2012;60:628–36. PubMed PMC

Willems S, Verma A, Betts TR, Murray S, Neuzil P, Ince Het al. . Targeting nonpulmonary vein sources in persistent atrial fibrillation identified by noncontact charge density mapping: UNCOVER AF trial. Circ Arrhythm Electrophysiol 2019;12:e007233. PubMed

Chauhan VS, Verma A, Nayyar S, Timmerman N, Tomlinson G, Porta-Sanchez Aet al. . Focal source and trigger mapping in atrial fibrillation: randomized controlled trial evaluating a novel adjunctive ablation strategy. Heart Rhythm 2020;17:683–91. PubMed

Xu CH, Xiong F, Jiang WF, Liu X, Liu T, Qin M. Rotor mechanism and its mapping in atrial fibrillation. Europace 2023;25:783–92. PubMed PMC

Guillem MS, Climent AM, Rodrigo M, Fernandez-Aviles F, Atienza F, Berenfeld O. Presence and stability of rotors in atrial fibrillation: evidence and therapeutic implications. Cardiovasc Res 2016;109:480–92. PubMed PMC

Mann I, Linton NWF, Coyle C, Howard JP, Fudge M, Lim Eet al. . RETRO-MAPPING: a new approach to activation mapping in persistent atrial fibrillation reveals evidence of spatiotemporal stability. Circ Arrhythm Electrophysiol 2021;14:e009602. PubMed

Pope MT, Kuklik P, Briosa EGA, Leo M, Mahmoudi M, Paisey Jet al. . Spatial and temporal variability of rotational, focal, and irregular activity: practical implications for mapping of atrial fibrillation. J Cardiovasc Electrophysiol 2021;32:2393–403. PubMed PMC

Gagyi RB, Ruppersberg P, Kong MH, Hoogendijk M, Wijchers S, Szili-Torok T. First-in-man demonstration of 18-month spatiotemporal stability of active atrial fibrillation source detected by electrographic flow mapping in persistent atrial fibrillation. Heart Rhythm Case Rep 2021;7:599–604. PubMed PMC

Gagyi RB, Bhagwandien RE, Yap SC, Hoogendijk M, Wijchers S, Szili-Torok T. Electrographic flow mapping guided catheter ablation offers advantages for patients with persistent atrial fibrillation. Pacing Clin Electrophysiol 2023;46:771–81. PubMed

Najít záznam

Citační ukazatele

Nahrávání dat ...

Možnosti archivace

Nahrávání dat ...