This work presents an affordable distance-based microfluidic paper-based device (μPAD), using polydiacetylene (PDA) liposome as a chromogenic substance with a smartphone-based photo editor, for rapid and in-field analysis of quaternary ammonium compounds (QACs) (e.g., didecyldimethylammonium chloride (DDAC), benzyldimethyltetradecyl ammonium chloride (BAC), and cetylpyridinium chloride (CPC)). In-field analysis of these compounds is important to ensure their antimicrobial activity and user safety since they are widely utilized as disinfectants in households and hospitals. The μPAD featured a thermometer-like shape consisting of a sample reservoir and a microchannel as the detection zone, which was pre-deposited with PDA liposome. The color change from blue to red appeared in the presence of QACs and the color bar lengths were proportional to the QAC concentrations. Reactions of QACs with the PDA required a specific pH range (from pH 4.0 to 10.0) and a readout time of 7 min. Analytical performance characteristics of the device were tested with DDAC, BAC, and CPC showing acceptable specificity, accuracy (96.1-109.4%), and precision (%RSDs ≤ 9.3%). Limits of detection and quantitation were in the ranges of 20 to 80 and 70 to 250 μM, respectively. Feasibility of the newly developed device was demonstrated for in-field analysis of QACs in fumigation solution providing comparable results with those obtained from a colorimetric assay (P > 0.05). The proposed device shows potentials for further applications of other analytes since it offers speed, simplicity, and affordability for in-field analysis, especially in remote areas where expertise, resources, and infrastructures are limited. Graphical abstract.
- Publikační typ
- časopisecké články MeSH
In-capillary derivatization using fluorescamine as the labeling reagent was proposed to enhance the detectability of adamantine drugs (memantine, amantadine and rimantadine) by spectrophotometric detection. Fluorescamine and the drugs were delivered to the capillary electrophoresis instrument at a ratio of 10:1 by zone injection. The derivatization reaction occurred following the application of voltage (20 kV). The derivatized products, hydrolyzed- fluorescamine and excess fluorescamine were separated in 7 min using 100 mM borate buffer (pH 10.0) containing 0.1% w/v of Brij®-35 and 20% v/v of acetonitrile. Validation data showed good linearity (r2 > 0.98), precision (%RSDs < 3.4), and accuracy (recoveries ranging from 98.0 to 102.0%). The detection and quantitation limits are in the range of 6.0-8.5 and 18-25 μM, respectively. The validation data is comparable to reported methods, however, the current method offers better precision with enhanced sensitivity (up to six times). Applications of the method show percent labeled amounts found in the studied samples within 100.6-109.3%, which complied with the United States Pharmacopeia limit (90.0-110.0%). The method was simple, rapid and, automated, which required no extra instrumentation or skillful operators.