BACKGROUND: To predict worsening heart failure hospitalizations (WHFHs), the HeartInsight multiparametric algorithm calculates a heart failure (HF) Score based on temporal trends of physiologic parameters obtained through automatic daily remote monitoring of implantable cardioverter-defibrillators (ICDs). OBJECTIVE: We studied the association of the baseline HF Score, determined at algorithm activation, with long-term patient outcomes. METHODS: Data from 9 clinical trials were pooled, including 1841 ICD patients with a preimplantation ejection fraction ≤35%, New York Heart Association class II/III, and no long-standing atrial fibrillation. The primary end point was a composite of death or WHFH. RESULTS: After a median follow-up of 631 days (interquartile range, 385-865 days), there were 243 WHFHs in 173 patients (9.4%) and 122 deaths (6.6%), 52 of which (42.6%) were cardiovascular. The primary end point occurred in 265 patients (14.4%). A multivariable time-to-first-event analysis showed that a high baseline HF Score (>23, as determined by a time-dependent receiver operating characteristics curve analysis) was significantly associated with the occurrence of the primary end point (adjusted hazard ratio [HR], 2.05; 95% confidence interval [CI], 1.54-2.71; P < .0001), all-cause death (HR, 2.37; CI, 1.56-3.58; P < .0001), cardiovascular death (HR, 2.19; CI, 1.14-4.22; P = .019), and WHFH (HR, 1.91; CI, 1.35-2.71; P = .0003). In a hierarchical event analysis of all-cause death as the outcome with highest priority and WHFHs as repeated event outcomes, the win ratio was 2.47 (CI, 1.89-3.24; P < .0001). CONCLUSION: Based on a retrospective analysis of clinical trial data with adjudicated events, baseline HF Score derived from device-monitored variables was able to stratify patients at higher long-term risk of death or WHFH.
- MeSH
- algoritmy MeSH
- časové faktory MeSH
- defibrilátory implantabilní * MeSH
- klinické zkoušky jako téma MeSH
- lidé středního věku MeSH
- lidé MeSH
- následné studie MeSH
- senioři MeSH
- srdeční selhání * terapie patofyziologie mortalita MeSH
- technologie dálkového snímání metody MeSH
- tepový objem fyziologie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
Deficit transportu riboflavinu (RTD), známý také jako Brown-Vialetto-van Laere syndrom, je vzácné onemocnění, které na základě poruchy oxidativního metabolizmu vede k úbytku neuronů v jádrech hlavových i periferních nervů. Projevy jsou ztráta svalové síly, ptóza očního víčka, bulbární syndrom a respirační potíže doprovázené těžkou postsynaptickou sluchovou neuropatií. Je-li projeven v dětském věku, vede k úmrtí pro respirační selhání v řádu měsíců až let. Na prezentovaném případu familiárního výskytu u sourozenců je demonstrována nutnost rychlého zahájení substituční léčby riboflavinem, která může předejít rozvoji onemocnění nebo alespoň zmírnit jeho projevy a zvýšit šanci na úspěšnou rehabilitaci sluchu. Při záchytu sluchové neuropatie u dětí doporučujeme vyšetření multigenového NGS/MPS panelu, který zahrnuje i vzácnější příčiny vrozené poruchy sluchu. V případě výskytu jakéhokoli dalšího příznaku onemocnění je třeba neprodleně zahájit substituční léčbu.
Riboflavin transporter deficiency (RTD) is rare disease characterized by progressive loss of cranial and somatic nerve function. Typically ptosis, bulbar syndrome, muscle weakness, and auditory neuropathy are manifested. Without treatment, this leads to death caused by respiratory failure, especially when it starts in childhood. In this paper, we present two siblings with RTD and demonstrate the necessity of early diagnosis and riboflavin substitution treatment. Riboflavin substitution can prevent hearing loss and increase the chance for successful hearing rehabilitation. Comparison with other existing literature is given. We recommend to test every child with captured auditory neuropathy spectrum disorder for a multi-gene NGS/MPS panel and provide substitution treatment before genetic test results, especially when other symptoms are manifested.
- MeSH
- dítě MeSH
- genetické testování MeSH
- kochleární implantáty MeSH
- kojenec MeSH
- lidé MeSH
- nedostatek riboflavinu * diagnóza genetika terapie MeSH
- poruchy sluchu etiologie terapie MeSH
- riboflavin terapeutické užití MeSH
- rodina MeSH
- Check Tag
- dítě MeSH
- kojenec MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- kazuistiky MeSH
- přehledy MeSH
Stimulací indukovaná kardiomyopatie (pacing-induced cardiomyopathy, PIcm) nemá mezinárodně akceptovanou definici, obecně se ale pod tímto pojmem rozumí srdeční selhání s ejekční frakcí levé komory < 50 % a současně její redukce ≥ 10 % po implantaci kardiostimulátoru bez jiné příčiny. Jedná se o komplikaci konvenční kardiostimulace, která je asociována s vyšší mortalitou z kardiovaskulárních příčin a ze všech příčin a častější nutností hospitalizací. Podíl komorové stimulace, který zvyšuje riziko vzniku PIcm, je > 20 %, nelze ale říct, že je nižší podíl bezpečný nebo že vyšší jednoznačně škodí. už při indikaci k trvalé kardiostimulaci je nutné identifikovat pacienty s vyšším rizikem vzniku PIcm a nabídnout jiné, (zatím) alternativní metody stimulace. u pacientů s konvenční kardiostimulací je nutné optimalizovat programaci k potlačení nežádoucí komorové stimulace s cílem co nejvíce snížit riziko vzniku PIcm. V případě již rozvinutého PIcm přichází v úvahu upgrade na srdeční resynchronizační léčbu (crT) nebo na stimulaci převodního systému (cSP), přičemž je vhodné výkon provést s co nejkratším časovým odstupem od rozpoznání PIcm.
Pacing-induced cardiomyopathy (PICM) does not have an internationally accepted definition. In general, the term refers to the heart failure with a left ventricular EF below 50% and its reduction ≥ 10% after implantation of a pacemaker without known cause. The pacing burden that increases the risk of PICM is > 20%. On the other hand, it cannot be said that a lower pacing burden is safe or that a higher pacing burden is clearly harmful. It is necessary to identify patients with a higher risk of developing PICM before the implantation of a pacemaker and offer other (for now) alternative methods of pacing. In the case of an already developed PICM, an upgrade to a CRT or a CSP should be considered. If indicated it is recommended to perform the upgrade without unnecessary delay after the recognition of the PICM.
- MeSH
- elektrostimulační terapie metody MeSH
- implantované elektrody škodlivé účinky MeSH
- kardiomyopatie * epidemiologie etiologie prevence a kontrola terapie MeSH
- kardiostimulace umělá * metody škodlivé účinky MeSH
- lidé MeSH
- převodní systém srdeční MeSH
- rizikové faktory kardiovaskulárních chorob MeSH
- srdeční resynchronizační terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- přehledy MeSH
BACKGROUND: Inappropriate therapy (IAT) is an undesirable side effect of implantable cardiac defibrillator (ICD) therapy. Early studies with the subcutaneous ICD (S-ICD) showed relatively high inappropriate shock (IAS) rates. The PRAETORIAN (Prospective Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) trial demonstrated that the S-ICD is noninferior to the transvenous ICD (TV-ICD) with regard to the combined end point of IAS and complications. This secondary analyses evaluates all IAT in the PRAETORIAN trial. METHODS: This international, multicenter trial randomized 849 patients with an indication for ICD therapy between S-ICD (n=426) and TV-ICD therapy (n=423). ICD programming was mandated by protocol. All analysis were performed in the modified intention-to-treat population. RESULTS: In both groups 42 patients experienced IAT (48-month Kaplan-Meier estimated cumulative incidence, 9.9% and 10.1%, respectively; hazard ratio (HR), 0.99 [95% CI, 0.65-1.52]; P=0.97). There was no significant difference in patients experiencing IAS between both groups (P=0.14). In the S-ICD group, 81 IAT episodes with 124 IAS and 1 inappropriate antitachycardia pacing occurred versus 89 IAT episodes with 130 IAS and 124 inappropriate antitachycardia pacing in the TV-ICD group. IAT episodes were most frequently caused by supraventricular tachycardias in the TV-ICD group (n=83/89) versus cardiac oversensing in the S-ICD group (n=40/81). In the TV-ICD group, a baseline heart rate >80 bpm (HR, 1.99 [95% CI, 1.05-3.76]; P=0.03), a history of atrial fibrillation (HR, 2.66 [95% CI, 1.41-5.02]; P=0.003), and smoking (HR, 2.46 [95% CI, 1.31-4.09]; P=0.005) were independent predictors for IAT. A QRS duration >120 ms was an independent predictor for IAT caused by cardiac oversensing in the S-ICD group (HR, 3.13 [95% CI, 1.34-7.31]; P=0.008). Post-IAS interventions significantly reduced IAS recurrence in both groups (P=0.046). CONCLUSIONS: There was no significant difference in IAT and IAS rates between the S-ICD and TV-ICD in a conventional ICD population, but causes and predictors for IAT differed between the devices. After the first IAS, an intervention significantly reduced the recurrence rate of IAS. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01296022.
- MeSH
- časové faktory MeSH
- defibrilátory implantabilní * MeSH
- elektrická defibrilace * přístrojové vybavení škodlivé účinky MeSH
- lidé středního věku MeSH
- lidé MeSH
- prospektivní studie MeSH
- rizikové faktory MeSH
- senioři MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- randomizované kontrolované studie MeSH
- srovnávací studie MeSH
BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) was developed to overcome the risk of lead-related complications associated with the transvenous implantable cardioverter-defibrillator (TV-ICD). In contrast to the TV-ICD, the S-ICD is a completely extrathoracic device. Subsequently, complications differ between these 2 implantable cardioverter-defibrillators, which might impact patient perceptions of the therapies. This prespecified secondary analysis of the PRAETORIAN trial evaluates differences in quality of life. METHODS: The PRAETORIAN trial (A Prospective, Randomized Comparison of Subcutaneous and Transvenous Implantable Cardioverter Defibrillator Therapy) randomized patients with an implantable cardioverter-defibrillator indication, without the need for pacing to S-ICD or TV-ICD therapy. Two questionnaires were collected at baseline, discharge, 12 months, and 30 months. The Duke Activity Status Index measures cardiac-specific physical functioning, and the 36-Item Short Form Health Survey measures physical and mental well-being, with the subscales bodily pain and mental health being of interest in this analysis. Mann-Whitney U tests were used to compare study arms, and a mixed model was used to describe the questionnaire outcomes over time. RESULTS: Patients were randomized to S-ICD (n=426) and TV-ICD (n=423). In the S-ICD group, 20% were women versus 19% in the TV-ICD group. The median age was 63 (interquartile range, 54-69) years in the S-ICD group versus 64 (interquartile range, 56-69) years in the TV-ICD group. There were no significant differences in the Duke Activity Status Index and 36-Item Short Form Health Survey subscales for bodily pain and mental health between the groups at any time point. Patients with a shock in the last 90 days had significantly lower scores for social functioning (P=0.008) and role limitations due to emotional problems (P=0.001) than patients without a shock, but this effect did not differ between treatment arms. CONCLUSIONS: In a large randomized cohort of patients with an S-ICD or TV-ICD, no difference in overall quality of life was observed. However, implantable cardioverter-defibrillator shocks resulted in a reduction in quality of life, regardless of the device type or appropriateness. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT01296022.
- MeSH
- časové faktory MeSH
- defibrilátory implantabilní * MeSH
- duševní zdraví * MeSH
- elektrická defibrilace * přístrojové vybavení škodlivé účinky MeSH
- funkční status MeSH
- kvalita života * MeSH
- lidé středního věku MeSH
- lidé MeSH
- náhlá srdeční smrt prevence a kontrola MeSH
- prospektivní studie MeSH
- protézy - design MeSH
- průzkumy a dotazníky MeSH
- rizikové faktory MeSH
- senioři MeSH
- srdeční arytmie terapie diagnóza patofyziologie MeSH
- výsledek terapie MeSH
- zdravotní stav MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- randomizované kontrolované studie MeSH
- srovnávací studie MeSH
BACKGROUND AND AIMS: Risk stratification of sudden cardiac death after myocardial infarction and prevention by defibrillator rely on left ventricular ejection fraction (LVEF). Improved risk stratification across the whole LVEF range is required for decision-making on defibrillator implantation. METHODS: The analysis pooled 20 data sets with 140 204 post-myocardial infarction patients containing information on demographics, medical history, clinical characteristics, biomarkers, electrocardiography, echocardiography, and cardiac magnetic resonance imaging. Separate analyses were performed in patients (i) carrying a primary prevention cardioverter-defibrillator with LVEF ≤ 35% [implantable cardioverter-defibrillator (ICD) patients], (ii) without cardioverter-defibrillator with LVEF ≤ 35% (non-ICD patients ≤ 35%), and (iii) without cardioverter-defibrillator with LVEF > 35% (non-ICD patients >35%). Primary outcome was sudden cardiac death or, in defibrillator carriers, appropriate defibrillator therapy. Using a competing risk framework and systematic internal-external cross-validation, a model using LVEF only, a multivariable flexible parametric survival model, and a multivariable random forest survival model were developed and externally validated. Predictive performance was assessed by random effect meta-analysis. RESULTS: There were 1326 primary outcomes in 7543 ICD patients, 1193 in 25 058 non-ICD patients ≤35%, and 1567 in 107 603 non-ICD patients >35% during mean follow-up of 30.0, 46.5, and 57.6 months, respectively. In these three subgroups, LVEF poorly predicted sudden cardiac death (c-statistics between 0.50 and 0.56). Considering additional parameters did not improve calibration and discrimination, and model generalizability was poor. CONCLUSIONS: More accurate risk stratification for sudden cardiac death and identification of low-risk individuals with severely reduced LVEF or of high-risk individuals with preserved LVEF was not feasible, neither using LVEF nor using other predictors.
- MeSH
- defibrilátory implantabilní * MeSH
- elektrokardiografie MeSH
- hodnocení rizik metody MeSH
- infarkt myokardu * mortalita komplikace MeSH
- lidé MeSH
- náhlá srdeční smrt * prevence a kontrola epidemiologie etiologie MeSH
- tepový objem * fyziologie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- metaanalýza MeSH
Hypertrofická kardiomyopatie je geneticky podmíněné onemocnění charakterizované zesílením stěn myokardu levé komory nad 15 mm při absenci jiné vysvětlující příčiny. Součástí diagnostiky a léčby pacientů s hypertrofickou kardiomyopatií je pátrání po obstrukci ve výtokovém traktu levé komory a její management, stratifikace rizika náhlé srdeční smrti, provedení genetického testování a screening rodinných pří- slušníků. Kazuistika popisuje případ mladého muže s chronickým dermatologickým onemocněním na trvalé biologické léčbě, s pozitivní rodinnou anamnézou náhlé srdeční smrti, u něhož byla nově diagnostikována hypertrofická kardiomyopatie se symptomatickou obstrukcí ve výtokovém traktu levé komory. U pacienta bylo indikováno provedení alkoholové septální ablace, která měla dobrý hemodynamický i klinický výsledek. V primární prevenci náhlé srdeční smrti mu byl implantován implantabilní kardioverter-defibrilátor, došlo však ke komplikaci v podobě časné infekce kapsy přístroje při pacientově kožním onemocnění a rozvoji reaktivní perikarditidy.
Hypertrophic cardiomyopathy is a genetic disorder characterized by increased left ventricle thickness greater than 15 milimetres in the absence of any other explanatory cause. The diagnostics and treatment of patients with hypertrophic cardiomyopathy include search for a management of left ventricular outflow tract obstruction, risk stratification for sudden cardiac death and genetic testing and screening of family members. This case report describes a young man with a chronic skin disease on permanent biological therapy who had a family history of sudden cardiac death and had recently been diagnosed with hypertrophic cardiomyopathy with symptomatic left ventricular outflow tract obstruction. An alcohol septal ablation had been indicated, resulting in improved hemodynamic and clinical outcome. An implantable cardioverter-defibrillator was implanted for the primary prevention of sudden cardiac death. However, an early device pocket infection due to the patient's skin disease and the development of reactive pericarditis led to complications.
- MeSH
- anamnéza MeSH
- defibrilátory implantabilní škodlivé účinky MeSH
- dospělí MeSH
- echokardiografie MeSH
- elektrokardiografie MeSH
- hemodynamické monitorování MeSH
- hidradenitis suppurativa * komplikace MeSH
- hypertrofická kardiomyopatie * diagnostické zobrazování genetika komplikace terapie MeSH
- lidé MeSH
- náhlá srdeční smrt prevence a kontrola MeSH
- perikarditida etiologie farmakoterapie MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mužské pohlaví MeSH
- Publikační typ
- kazuistiky MeSH
- MeSH
- defibrilátory implantabilní MeSH
- kardiologie MeSH
- kardiovaskulární nemoci * ošetřování MeSH
- lidé MeSH
- paliativní péče * MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- přehledy MeSH