Nejvíce citovaný článek - PubMed ID 17420350
Pulse pressure amplification (PPA) is the brachial-to-aortic pulse pressure ratio and decreases with age and cardiovascular risk factors. This individual-participant meta-analysis of population studies aimed to define an outcome-driven threshold for PPA. Incidence rates and standardized multivariable-adjusted hazard ratios (HRs) of cardiovascular and coronary endpoints associated with PPA, as assessed by the SphygmoCor software, were evaluated in the International Database of Central Arterial Properties for Risk Stratification (n = 5608). Model refinement was assessed by the integrated discrimination (IDI) and net reclassification (NRI) improvement. Age ranged from 30 to 96 years (median 53.6). Over 4.1 years (median), 255 and 109 participants experienced a cardiovascular or coronary endpoint. In a randomly defined discovery subset of 3945 individuals, the rounded risk-carrying PPA thresholds converged at 1.3. The HRs for cardiovascular and coronary endpoints contrasting PPA < 1.3 vs ≥1.3 were 1.54 (95% confidence interval [CI]: 1.00-2.36) and 2.45 (CI: 1.20-5.01), respectively. Models were well calibrated, findings were replicated in the remaining 1663 individuals analyzed as test dataset, and NRI was significant for both endpoints. The HRs associating cardiovascular and coronary endpoints per PPA threshold in individuals <60 vs ≥60 years were 3.86 vs 1.19 and 6.21 vs 1.77, respectively. The proportion of high-risk women (PPA < 1.3) was higher at younger age (<60 vs ≥60 years: 67.7% vs 61.5%; P < 0.001). In conclusion, over and beyond common risk factors, a brachial-to-central PP ratio of <1.3 is a forerunner of cardiovascular coronary complications and is an underestimated risk factor in women aged 30-60 years. Our study supports pulse wave analysis for risk stratification.
- Klíčová slova
- Pulse pressure amplification, Waveform analysis, Cardiovascular risk, Population science,
- MeSH
- analýza pulzové vlny MeSH
- arteria brachialis fyziologie MeSH
- dospělí MeSH
- kardiovaskulární nemoci * patofyziologie MeSH
- krevní tlak * fyziologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- rizikové faktory kardiovaskulárních chorob MeSH
- rizikové faktory MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- metaanalýza MeSH
BACKGROUND: Aortic pulse wave velocity (PWV) predicts cardiovascular events (CVEs) and total mortality (TM), but previous studies proposing actionable PWV thresholds have limited generalizability. This individual-participant meta-analysis is aimed at defining, testing calibration, and validating an outcome-driven threshold for PWV, using 2 populations studies, respectively, for derivation IDCARS (International Database of Central Arterial Properties for Risk Stratification) and replication MONICA (Monitoring of Trends and Determinants in Cardiovascular Disease Health Survey - Copenhagen). METHODS: A risk-carrying PWV threshold for CVE and TM was defined by multivariable Cox regression, using stepwise increasing PWV thresholds and by determining the threshold yielding a 5-year risk equivalent with systolic blood pressure of 140 mm Hg. The predictive performance of the PWV threshold was assessed by computing the integrated discrimination improvement and the net reclassification improvement. RESULTS: In well-calibrated models in IDCARS, the risk-carrying PWV thresholds converged at 9 m/s (10 m/s considering the anatomic pulse wave travel distance). With full adjustments applied, the threshold predicted CVE (hazard ratio [CI]: 1.68 [1.15-2.45]) and TM (1.61 [1.01-2.55]) in IDCARS and in MONICA (1.40 [1.09-1.79] and 1.55 [1.23-1.95]). In IDCARS and MONICA, the predictive accuracy of the threshold for both end points was ≈0.75. Integrated discrimination improvement was significant for TM in IDCARS and for both TM and CVE in MONICA, whereas net reclassification improvement was not for any outcome. CONCLUSIONS: PWV integrates multiple risk factors into a single variable and might replace a large panel of traditional risk factors. Exceeding the outcome-driven PWV threshold should motivate clinicians to stringent management of risk factors, in particular hypertension, which over a person's lifetime causes stiffening of the elastic arteries as waypoint to CVE and death.
- Klíčová slova
- cardiovascular diseases, diabetes mellitus, hypertension, metabolic syndrome, pulse wave analysis,
- MeSH
- analýza pulzové vlny škodlivé účinky MeSH
- aorta MeSH
- arterie MeSH
- hypertenze * diagnóza epidemiologie komplikace MeSH
- kardiovaskulární nemoci * diagnóza epidemiologie etiologie MeSH
- lidé MeSH
- rizikové faktory MeSH
- tuhost cévní stěny * fyziologie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- metaanalýza MeSH
- práce podpořená grantem MeSH
Major adverse cardiovascular events are closely associated with 24-hour blood pressure (BP). We determined outcome-driven thresholds for 24-hour mean arterial pressure (MAP), a BP index estimated by oscillometric devices. We assessed the association of major adverse cardiovascular events with 24-hour MAP, systolic BP (SBP), and diastolic BP (DBP) in a population-based cohort (n=11 596). Statistics included multivariable Cox regression and the generalized R2 statistic to test model fit. Baseline office and 24-hour MAP averaged 97.4 and 90.4 mm Hg. Over 13.6 years (median), 2034 major adverse cardiovascular events occurred. Twenty-four-hour MAP levels of <90 (normotension, n=6183), 90 to <92 (elevated MAP, n=909), 92 to <96 (stage-1 hypertension, n=1544), and ≥96 (stage-2 hypertension, n=2960) mm Hg yielded equivalent 10-year major adverse cardiovascular events risks as office MAP categorized using 2017 American thresholds for office SBP and DBP. Compared with 24-hour MAP normotension, hazard ratios were 0.96 (95% CI, 0.80-1.16), 1.32 (1.15-1.51), and 1.77 (1.59-1.97), for elevated and stage-1 and stage-2 hypertensive MAP. On top of 24-hour MAP, higher 24-hour SBP increased, whereas higher 24-hour DBP attenuated risk (P<0.001). Considering the 24-hour measurements, R2 statistics were similar for SBP (1.34) and MAP (1.28), lower for DBP than for MAP (0.47), and reduced to null, if the base model included SBP and DBP; if the ambulatory BP indexes were dichotomized according to the 2017 American guideline and the proposed 92 mm Hg for MAP, the R2 values were 0.71, 0.89, 0.32, and 0.10, respectively. In conclusion, the clinical application of 24-hour MAP thresholds in conjunction with SBP and DBP refines risk estimates.
- Klíčová slova
- cardiovascular disease, hypertension, mean arterial pressure, mortality, oscillometry,
- MeSH
- ambulantní monitorování krevního tlaku * MeSH
- dospělí MeSH
- hypertenze komplikace MeSH
- kardiovaskulární nemoci etiologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- proporcionální rizikové modely MeSH
- senioři MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Research Support, N.I.H., Extramural MeSH
The new American College of Cardiology/American Heart Association guideline reclassified office blood pressure and proposed thresholds for ambulatory blood pressure (ABP). We derived outcome-driven ABP thresholds corresponding with the new office blood pressure categories. We performed 24-hour ABP monitoring in 11 152 participants (48.9% women; mean age, 53.0 years) representative of 13 populations. We determined ABP thresholds resulting in multivariable-adjusted 10-year risks similar to those associated with elevated office blood pressure (120/80 mm Hg) and stages 1 and 2 of office hypertension (130/80 and 140/90 mm Hg). Over 13.9 years (median), 2728 (rate per 1000 person-years, 17.9) people died, 1033 (6.8) from cardiovascular disease; furthermore, 1988 (13.8), 893 (6.0), and 795 (5.4) cardiovascular and coronary events and strokes occurred. Using a composite cardiovascular end point, systolic/diastolic outcome-driven thresholds indicating elevated 24-hour, daytime, and nighttime ABP were 117.9/75.2, 121.4/79.6, and 105.3/66.2 mm Hg. For stages 1 and 2 ambulatory hypertension, thresholds were 123.3/75.2 and 128.7/80.7 mm Hg for 24-hour ABP, 128.5/79.6 and 135.6/87.1 mm Hg for daytime ABP, and 111.7/66.2 and 118.1/72.5 mm Hg for nighttime ABP. ABP thresholds derived from other end points were similar. After rounding, approximate thresholds for elevated 24-hour, daytime, and nighttime ABP were 120/75, 120/80, and 105/65 mm Hg, and for stages 1 and 2, ambulatory hypertension 125/75 and 130/80 mm Hg, 130/80 and 135/85 mm Hg, and 110/65 and 120/70 mm Hg. Outcome-driven ABP thresholds corresponding to elevated blood pressure and stages 1 and 2 of hypertension are similar to those proposed by the current American College of Cardiology/American Heart Association guideline.
- Klíčová slova
- United States, blood pressure monitoring, ambulatory, hypertension,
- MeSH
- ambulantní monitorování krevního tlaku metody MeSH
- Americká kardiologická asociace MeSH
- dospělí MeSH
- hypertenze komplikace diagnóza patofyziologie MeSH
- kardiovaskulární nemoci etiologie patofyziologie MeSH
- krevní tlak fyziologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- rizikové faktory MeSH
- senioři MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Spojené státy americké MeSH