Extracorporeal membrane oxygenation (ECMO) has been used increasingly for both respiratory and cardiac failure in adult patients. Indications for ECMO use in cardiac failure include severe refractory cardiogenic shock, refractory ventricular arrhythmia, active cardiopulmonary resuscitation for cardiac arrest, and acute or decompensated right heart failure. Evidence is emerging to guide the use of this therapy for some of these indications, but there remains a need for additional evidence to guide best practices. As a result, the use of ECMO may vary widely across centers. The purpose of this document is to highlight key aspects of care delivery, with the goal of codifying the current use of this rapidly growing technology. A major challenge in this field is the need to emergently deploy ECMO for cardiac failure, often with limited time to assess the appropriateness of patients for the intervention. For this reason, we advocate for a multidisciplinary team of experts to guide institutional use of this therapy and the care of patients receiving it. Rigorous patient selection and careful attention to potential complications are key factors in optimizing patient outcomes. Seamless patient transport and clearly defined pathways for transition of care to centers capable of providing heart replacement therapies (e.g., durable ventricular assist device or heart transplantation) are essential to providing the highest level of care for those patients stabilized by ECMO but unable to be weaned from the device. Ultimately, concentration of the most complex care at high-volume centers with advanced cardiac capabilities may be a way to significantly improve the care of this patient population.
- Klíčová slova
- Cardiac arrest, Cardiac failure, Critical care networks, Extracorporeal life support, Extracorporeal membrane oxygenation, Hospital organization, Mechanical circulatory support, Position article,
- MeSH
- dospělí MeSH
- kardiogenní šok * MeSH
- lidé MeSH
- mimotělní membránová oxygenace * MeSH
- podpůrné srdeční systémy MeSH
- srdeční selhání * terapie MeSH
- transplantace srdce MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
INTRODUCTION: Veno-arterial extracorporeal life support (ECLS) is increasingly being used to treat rapidly progressing or severe cardiogenic shock. However, it has been repeatedly shown that increased afterload associated with ECLS significantly diminishes left ventricular (LV) performance. The objective of the present study was to compare LV function and coronary flow during standard continuous-flow ECLS support and electrocardiogram (ECG)-synchronized pulsatile ECLS flow in a porcine model of cardiogenic shock. METHODS: Sixteen female swine (mean body weight 45 kg) underwent ECLS implantation under general anesthesia and artificial ventilation. Subsequently, acute cardiogenic shock, with documented signs of tissue hypoperfusion, was induced by initiating global myocardial hypoxia. Hemodynamic cardiac performance variables and coronary flow were then measured at different rates of continuous or pulsatile ECLS flow (ranging from 1 L/min to 4 L/min) using arterial and venous catheters, a pulmonary artery catheter, an LV pressure-volume loop catheter, and a Doppler coronary guide-wire. RESULTS: Myocardial hypoxia resulted in declines in mean cardiac output to 1.7±0.7 L/min, systolic blood pressure to 64±22 mmHg, and LV ejection fraction (LVEF) to 22±7%. Synchronized pulsatile flow was associated with a significant reduction in LV end-systolic volume by 6.2 mL (6.7%), an increase in LV stroke volume by 5.0 mL (17.4%), higher LVEF by 4.5% (18.8% relative), cardiac output by 0.37 L/min (17.1%), and mean arterial pressure by 3.0 mmHg (5.5%) when compared with continuous ECLS flow at all ECLS flow rates (P<0.05). At selected ECLS flow rates, pulsatile flow also reduced LV end-diastolic pressure, end-diastolic volume, and systolic pressure. ECG-synchronized pulsatile flow was also associated with significantly increased (7% to 22%) coronary flow at all ECLS flow rates. CONCLUSION: ECG-synchronized pulsatile ECLS flow preserved LV function and coronary flow compared with standard continuous-flow ECLS in a porcine model of cardiogenic shock.
- MeSH
- elektrokardiografie metody MeSH
- funkce levé komory srdeční fyziologie MeSH
- hemodynamika MeSH
- kardiogenní šok patologie patofyziologie terapie MeSH
- koronární cévy patofyziologie MeSH
- koronární cirkulace fyziologie MeSH
- mimotělní membránová oxygenace metody MeSH
- modely nemocí na zvířatech * MeSH
- prasata * MeSH
- pulzatilní průtok fyziologie MeSH
- resuscitační péče metody MeSH
- zvířata MeSH
- Check Tag
- ženské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
BACKGROUND: The aim of this study was to assess the relationship between extracorporeal blood flow (EBF) and left ventricular (LV) performance during venoarterial extracorporeal membrane oxygenation (VA ECMO) therapy. METHODS: Five swine (body weight 45 kg) underwent VA ECMO implantation under general anesthesia and artificial ventilation. Subsequently, acute cardiogenic shock with signs of tissue hypoxia was induced. Hemodynamic and cardiac performance parameters were then measured at different levels of EBF (ranging from 1 to 5 L/min) using arterial and venous catheters, a pulmonary artery catheter and a pressure-volume loop catheter introduced into the left ventricle. RESULTS: Myocardial hypoxia resulted in a decline in mean (±SEM) cardiac output to 2.8 ± 0.3 L/min and systolic blood pressure (SBP) to 60 ± 7 mmHg. With an increase in EBF from 1 to 5 L/min, SBP increased to 97 ± 8 mmHg (P < 0.001); however, increasing EBF from 1 to 5 L/min significantly negatively influences several cardiac performance parameters: cardiac output decreased form 2.8 ± 0.3 L/min to 1.86 ± 0.53 L/min (P < 0.001), LV end-systolic volume increased from 64 ± 11 mL to 83 ± 14 mL (P < 0.001), LV stroke volume decreased from 48 ± 9 mL to 40 ± 8 mL (P = 0.045), LV ejection fraction decreased from 43 ± 3 % to 32 ± 3 % (P < 0.001) and stroke work increased from 2096 ± 342 mmHg mL to 3031 ± 404 mmHg mL (P < 0.001). LV end-diastolic pressure and volume were not significantly affected. CONCLUSIONS: The results of the present study indicate that higher levels of VA ECMO blood flow in cardiogenic shock may negatively affect LV function. Therefore, it appears that to mitigate negative effects on LV function, optimal VA ECMO blood flow should be set as low as possible to allow adequate tissue perfusion.
- MeSH
- funkce levé komory srdeční * MeSH
- hemodynamika MeSH
- kardiogenní šok patofyziologie MeSH
- koronární cévy patologie patofyziologie MeSH
- koronární cirkulace fyziologie MeSH
- mimotělní membránová oxygenace * MeSH
- modely nemocí na zvířatech MeSH
- myokard patologie MeSH
- tlak MeSH
- zvířata MeSH
- Check Tag
- ženské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH