Nejvíce citovaný článek - PubMed ID 27547832
Percutaneous Epicardial Pacing using a Novel Insulated Multi-electrode Lead
BACKGROUND: Arrhythmia management is a complex process involving both pharmacological and non-pharmacological approaches. Radiofrequency ablation is the pillar of nonpharmacological arrhythmia treatment. Unipolar ablation is considered to be the gold standard in the treatment of the majority of arrhythmias; however, its efficacy is limited to specific cases. In particular, the creation of deep or transmural lesions to eliminate intramurally originating arrhythmias remains inadequate. Bipolar ablation is proposed as an alternative to overcome unipolar ablation boundaries. RESULTS: Despite promising results gained from in vitro and animal studies showing that bipolar ablation is superior in creating transmural lesions, the use of bipolar ablation in daily clinical practice is limited. Several studies have been published showing that bipolar ablation is effective in the treatment of clinical arrhythmias after failed unipolar ablation, however, there is inconsistency regarding the safety of bipolar ablation within the available research papers. According to research evidence, the most common indications for bipolar ablation use are ventricular originating rhythmic disorders in patients with structural heart disease resistant to standard radiofrequency ablation. CONCLUSION: To allow wider clinical application the efficiency and safety of bipolar ablation need to be verified in future studies.
- Klíčová slova
- Bipolar radiofrequency ablation, arrhythmias, efficacy, heart disease, radiofrequency ablation, safety.,
- MeSH
- katetrizační ablace metody MeSH
- lidé MeSH
- nemoci srdce komplikace terapie MeSH
- srdeční arytmie patologie terapie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
INTRODUCTION: Epicardial defibrillation systems currently require surgical access. We aimed to develop a percutaneous defibrillation system with partially-insulated epicardial coils to focus electrical energy on the myocardium and prevent or minimize extra-cardiac stimulation. METHODS: We tested 2 prototypes created for percutaneous introduction into the pericardial space via a steerable sheath. This included a partially-insulated defibrillation coil and a defibrillation mesh with a urethane balloon acting as an insulator to the face of the mesh not in contact with the epicardium. The average energy associated with a chance of successful defibrillation 75% of the time (ED75) was calculated for each experiment. RESULTS: Of 16 animal experiments, 3 pig experiments had malfunctioning mesh prototypes such that results were unreliable; these were excluded. Therefore, 13 animal experiments were analyzed - 6 canines (29.8±4.0kg); 7 pigs (41.1±4.4kg). The overall ED75 was 12.8±6.7J (10.9±9.1J for canines; 14.4±3.9J in pigs [P=0.37]). The lowest ED75 obtained in canines was 2.5J while in pigs it was 9.5J. The lowest energy resulting in successful defibrillation was 2J in canines and 5J in pigs. There was no evidence of coronary vessel injury or trauma to extra-pericardial structures. CONCLUSION: Percutaneous, epicardial defibrillation using a partially insulated coil is feasible and appears to be associated with low defibrillation thresholds. Focusing insulation may limit extra-cardiac stimulation and potentially lower energy requirements for efficient defibrillation.
- Klíčová slova
- ICD, arrhythmia, defibrillation, epicardial, insulation, percutaneous,
- MeSH
- defibrilátory * MeSH
- elektrická defibrilace přístrojové vybavení metody MeSH
- perikard MeSH
- prasata MeSH
- psi MeSH
- zvířata MeSH
- Check Tag
- mužské pohlaví MeSH
- psi MeSH
- ženské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH