BACKGROUND: Drug-eluting stents (DESs) based on biodegradable polymers (BPs) have been introduced to reduce the risk for late and very late stent thrombosis (ST), which were frequently observed with earlier generations of DES designs based on durable polymers (DPs); however, randomized controlled trials on these DES designs are scarce. The meriT-V trial is a randomized, active-controlled, non-inferiority trial with a prospective, multicenter design that evaluated the 2-year efficacy of a novel third-generation, ultra-thin strut, BP-based BioMime sirolimus-eluting stent (SES) versus the DP-based XIENCE everolimus-eluting stent (EES) for the treatment of de novo lesions. METHODS: The meriT-V is a randomized trial that enrolled 256 patients at 15 centers across Europe and Brazil. Here, we report the outcomes of the extended follow-up period of 2 years. The randomization of enrolled patients was in a 2:1 ratio; the enrolled patients received either the BioMime SES (n = 170) or the XIENCE EES (n = 86). The three-point major adverse cardiac event (MACE), defined as a composite of cardiac death, myocardial infarction (MI), or ischemia-driven target vessel revascularization (ID-TVR), was considered as the composite safety and efficacy endpoint. Ischemia-driven target lesion revascularization (ID-TLR) was evaluated as well as the frequency of definite/probable ST, based on the first Academic Research Consortium definitions. RESULTS: The trial had a 2-year follow-up completion rate of 98.44% (n = 252/256 patients), and the clinical outcomes assessment showed a nonsignificant difference in the cumulative rate of three-point MACE between both arms (BioMime vs. XIENCE: 7.74% vs. 9.52%, P = 0.62). Even the MI incidences in the BioMime arm were insignificantly lower than those of the XIENCE arm (1.79% vs. 5.95%, P = 0.17). Late ST was observed in 1.19% cases of the XIENCE arm, while there were no such cases in the BioMime arm (P = 0.16). CONCLUSIONS: The objective comparisons between the novel BP-based BioMime SES and the well-established DP-based XIENCE EES in this randomized controlled trial show acceptable outcomes of both the devices in the cardiac deaths, MI, ID-TVR, and ST. Moreover, since there were no incidences of cardiac death in the entire study sample over the course of 2 years, we contend that the findings of the study are highly significant for both these DES designs. In this preliminary comparative trial, the device safety of BioMime SES can be affirmed to be acceptable, considering the lower three-point MACE rate and absence of late ST in the BioMime arm over the 2-year period.
- Klíčová slova
- Coronary artery disease, Drug-eluting stent, Everolimus, Major adverse cardiac events, Percutaneous coronary intervention, Sirolimus, Stent thrombosis,
- Publikační typ
- časopisecké články MeSH
BACKGROUND: The objective of this study was to assess regional and ethnic differences in an unselected patient population treated with polymer-free sirolimus-eluting stents (PF-SES) in Asia and Europe. METHODS: Two all-comers observational studies based on the same protocol (ClinicalTrials.gov Identifiers: NCT02629575 and NCT02905214) were combined for data analysis to assure sufficient statistical power. The primary endpoint was the accumulated target lesion revascularization (TLR) rate at 9-12 months. RESULTS: Of the total population of 7243 patients, 44.0% (3186) were recruited in the Mediterranean region and 32.0% (2317) in central Europe. The most prominent Asian region was South Korea (17.6%, 1274) followed by Malaysia (5.7%, 413). Major cardiovascular risk factors varied significantly across regions. The overall rates for accumulated TLR and MACE were low with 2.2% (140/6374) and 4.4% (279/6374), respectively. In ACS patients, there were no differences in terms of MACE, TLR, MI and accumulated mortality between the investigated regions. Moreover, dual antiplatelet therapy (DAPT) regimens were substantially longer in Asian countries even in patients with stable coronary artery disease as compared to those in Europe. CONCLUSIONS: PF-SES angioplasty is associated with low clinical event rates in all regions. Further reductions in clinical event rates seem to be associated with longer DAPT regimens.
- MeSH
- etnicita statistika a číselné údaje MeSH
- imunosupresiva terapeutické užití MeSH
- incidence MeSH
- infarkt myokardu epidemiologie prevence a kontrola MeSH
- koronární angioplastika metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- následné studie MeSH
- nemoci koronárních tepen terapie MeSH
- polymery MeSH
- prognóza MeSH
- prospektivní studie MeSH
- senioři MeSH
- sirolimus terapeutické užití MeSH
- stenty uvolňující léky * MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Geografické názvy
- Evropa epidemiologie MeSH
- Korejská republika epidemiologie MeSH
- Malajsie epidemiologie MeSH
- Středomoří epidemiologie MeSH
- Názvy látek
- imunosupresiva MeSH
- polymery MeSH
- sirolimus MeSH