Nejvíce citovaný článek - PubMed ID 28406705
Tolerance of isolated rabbit hearts to short ischemic periods is affected by increased LV mass fraction
Optical mapping is a fluorescence-based physiological method to image spreading of action potential in excitable tissues, such as the heart and central nervous system. Because of the requirements for high speed imaging in low light conditions, highly sensitive high-speed cameras together with an optical system with maximum photon efficiency are required. While the optimization of these two components is relatively straightforward, the choice of the perfect light source is less simple; depending on the other (usually fixed) components, various parameters may acquire different weight in decision-making process. Here we describe the rationale for building an optical mapping setup and consider the relative advantages and disadvantages of three different commonly available light sources: mercury vapor lamp (HBO), xenon lamp (XBO), and light emitting diode (LED). Using the same optical system (fluorescence macroscope) and high-speed camera (Ultima L), we have tested each of the sources for its ability to provide bright and even illumination of the field of view and measured its temporal fluctuations in intensity. Then we used each in the actual optical mapping experiment using isolated, perfused adult mouse heart or chick embryonic heart to determine the actual signal to noise ratio at various acquisition rates. While the LED sources have undergone significant improvements in the recent past, the other alternatives may still surpass them in some parameters, so they may not be the automatic number one choice for every application.
- MeSH
- akční potenciály MeSH
- fluorescenční barviva chemie MeSH
- kuřecí embryo MeSH
- myši MeSH
- srdce fyziologie MeSH
- světlo MeSH
- vápník analýza metabolismus MeSH
- zobrazování pomocí barviva citlivého na potenciál metody normy MeSH
- zvířata MeSH
- Check Tag
- kuřecí embryo MeSH
- myši MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- fluorescenční barviva MeSH
- vápník MeSH
BACKGROUND: Detailed quantitative analysis of the effect of left ventricle (LV) hypertrophy on myocardial ischemia manifestation in ECG is still missing. The associations between both phenomena can be studied in animal models. In this study, rabbit isolated hearts with spontaneously increased LV mass were used to evaluate the effect of such LV alteration on ischemia detection criteria and performance. METHODS: Electrophysiological effects of increased LV mass were evaluated on sixteen New Zealand rabbit isolated hearts under non-ischemic and ischemic conditions by analysis of various electrogram (EG) parameters. To reveal hearts with increased LV mass, LV weight/heart weight ratio was proposed. Standard paired and unpaired statistical tests and receiver operating characteristics analysis were used to compare data derived from different groups of animals, monitor EG parameters during global ischemia and evaluate their ability to discriminate between unchanged and increased LV as well as non-ischemic and ischemic state. RESULTS: Successful evaluation of both increased LV mass and ischemia is lead-dependent. Particularly, maximal deviation of QRS and area under QRS associated with anterolateral heart wall respond significantly to even early phase (the 1st-3rd min) of ischemia. Besides ischemia, these parameters reflect increased LV mass as well (with sensitivity reaching approx. 80%). However, the sensitivity of the parameters to both phenomena may lead to misinterpretations, when inappropriate criteria for ischemia detection are selected. Particularly, use of cut-off-based criteria defined from control group for ischemia detection in hearts with increased LV mass may result in dramatic reduction (approx. 15%) of detection specificity due to increased number of false positives. Nevertheless, criteria adjusted to particular experimental group allow achieving ischemia detection sensitivity of 89-100% and specificity of 94-100%, respectively. CONCLUSIONS: It was shown that response of the heart to myocardial ischemia can be successfully evaluated only when taking into account heart-related factors (such as LV mass) and other methodological aspects (such as recording electrodes position, selected EG parameters, cut-off criteria, etc.). Results of this study might be helpful for developing new clinical diagnostic strategies in order to improve myocardial ischemia detection in patients with LV hypertrophy.
- Klíčová slova
- Electrogram, Increased left ventricular mass, Isolated heart, Myocardial ischemia detection, ROC analysis, Rabbit,
- MeSH
- elektrofyziologické techniky kardiologické * MeSH
- elektrokardiografie * MeSH
- funkce levé komory srdeční * MeSH
- hypertrofie levé komory srdeční komplikace diagnóza patofyziologie MeSH
- ischemická choroba srdeční komplikace diagnóza patofyziologie MeSH
- králíci MeSH
- modely nemocí na zvířatech MeSH
- plocha pod křivkou MeSH
- počítačové zpracování signálu MeSH
- prediktivní hodnota testů MeSH
- preparace izolovaného srdce MeSH
- remodelace komor * MeSH
- rizikové faktory MeSH
- ROC křivka MeSH
- zvířata MeSH
- Check Tag
- králíci MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- zvířata MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH