Nejvíce citovaný článek - PubMed ID 29287104
Fetal head size and effect of manual perineal protection
BACKGROUND: The exact positioning of the dominant hand at the time of manual perineal protection (MPP) is not clearly specified. The main aim of this work was to identify the place on the perineum where pressure needs to be applied to achieve optimal forward fetal head displacement away from the anal sphincters using the bregma to posterior fourchette distance (BFD) and the perineal body length (PBL). METHODS: This was a two-center prospective cohort study. Term cephalic singleton nulliparous women having spontaneous vaginal delivery were considered eligible for recruitment into the study. Once crowning was diagnosed and just prior the initiation of manual perineal protection (MPP) or cutting an episiotomy, the BFD and PBL were measured using a standardized measurement protocol. RESULTS AND DISCUSSION: A total of 100 women (50 women in each center) were recruited into the study. The overall mean BFD was 2.8 ± 0.5 cm. The overall mean PBL was 4.4 ± 0.8 cm. There were no statistically significant differences between the measurements taken in both units regarding BFD or PBL (p = 0.81 and 0.10 respectively). There was a weak correlation between both measurements. Based on our measured parameters, it seems that the most effective point to apply perineal pressure to displace the head away from the anus is approximately 1 - 1.5 cm anterior to the anal margin. CONCLUSION: Measurements generated by this study will form the bases of future biomechanical studies to confirm their validity.
- Klíčová slova
- Manual perineal protection, Perineal body, Perineal mapping, Perineal tension,
- MeSH
- anální kanál fyziologie MeSH
- dospělí MeSH
- epiziotomie * statistika a číselné údaje metody MeSH
- hlava * MeSH
- lidé MeSH
- mladý dospělý MeSH
- perineum * MeSH
- prospektivní studie MeSH
- těhotenství MeSH
- tlak MeSH
- vedení porodu metody MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mladý dospělý MeSH
- těhotenství MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
INTRODUCTION AND HYPOTHESIS: Several studies have assessed birth-related deformations of the levator ani muscle (LAM) and perineum on models that depicted these elements in isolation. The main aim of this study was to develop a complex female pelvic floor computational model using the finite element method to evaluate points and timing of maximum stress at the LAM and perineum in relation to the birth process. METHODS: A three-dimensional computational model of the female pelvic floor was created and used to simulate vaginal birth based on data from previously described real-life MRI scans. We developed three models: model A (LAM without perineum); model B (perineum without LAM); model C (a combined model with both structures). RESULTS: The maximum stress in the LAM was achieved when the vertex was 9 cm below the ischial spines and measured 37.3 MPa in model A and 88.7 MPa in model C. The maximum stress in the perineum occurred at the time of distension by the suboocipito-frontal diameter and reached 86.7 MPa and 119.6 MPa in models B and C, respectively, while the stress in the posterior fourchette caused by the suboccipito-bregmatic diameter measured 36.9 MPa for model B and 39.8 MPa for model C. CONCLUSIONS: Including perineal structures in a computational birth model simulation affects the level of stress at the LAM. The maximum stress at the LAM and perineum seems to occur when the head is lower than previously anticipated.
- Klíčová slova
- Birth, Delivery, Levator, Modeling, Muscle, Partum, Perineal, Stress, Tension,
- MeSH
- analýza metodou konečných prvků MeSH
- lidé MeSH
- pánevní dno * diagnostické zobrazování MeSH
- perineum MeSH
- těhotenství MeSH
- vedení porodu * MeSH
- zubní porcelán MeSH
- Check Tag
- lidé MeSH
- těhotenství MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- finesse MeSH Prohlížeč
- zubní porcelán MeSH
INTRODUCTION AND HYPOTHESIS: Quantitative characterization of the birth canal and critical structures before delivery may provide risk assessment for maternal birth injury. The objective of this study was to explore imaging capability of an antepartum tactile imaging (ATI) probe. METHODS: Twenty randomly selected women older than 21 years with completed 35th week of pregnancy and a premise of vaginal delivery were enrolled in the feasibility study. The biomechanical data were acquired using the ATI probe with a double-curved surface, shaped according to the fetal skull and equipped with 168 tactile sensors and an electromagnetic motion tracking sensor. Software package COMSOL Multiphysics was used for finite element modeling. Subjects were asked for assessment of pain and comfort levels experienced during the ATI examination. RESULTS: All 20 nulliparous women were successfully examined with the ATI. Mean age was 27.8 ± 4.1 years, BMI 30.7 ± 5.8, and week of pregnancy 38.8 ± 1.4. Biomechanical mapping with the ATI allowed real-time observation of the probe location, applied load to the vaginal walls, and a 3D tactile image composition. The nonlinear finite element model describing the stress-strain relationship of the pelvic tissue was developed and used for calculation of Young's modulus (E). Average perineal elastic modulus was 11.1 ± 4.3 kPa, levator ani 4.8 ± 2.4 kPa, and symphysis-perineum distance was 30.1 ± 6.9 mm. The pain assessment level for the ATI examination was 2.1 ± 0.8 (scale 1-4); the comfort level was 2.05 ± 0.69 (scale 1-3). CONCLUSIONS: The antepartum examination with the ATI probe allowed measurement of the tissue elasticity and anatomical distances. The pain level was low and the comfort level was comparable with manual palpation.
- Klíčová slova
- Biomechanics of parturition, Elastography, Finite element model, Perineal elasticity, Tactile imaging,
- MeSH
- dospělí MeSH
- elastografie * MeSH
- lidé MeSH
- mladý dospělý MeSH
- pánevní dno * diagnostické zobrazování MeSH
- perineum diagnostické zobrazování MeSH
- porod MeSH
- studie proveditelnosti MeSH
- těhotenství MeSH
- zobrazování trojrozměrné MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- mladý dospělý MeSH
- těhotenství MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Manual perineal protection (MPP) is an intrapartum intervention suggested to protect perineal integrity during childbirth. Proper execution of MPP is complex and evaluation of its true contribution is difficult in the clinical setting because of the large number of obstetric variables, some of which are hardly quantifiable. In this study we aimed to gather initial data on the forces executed by the accoucheur's thumb, index and middle fingers during MPP at the time of fetal head expulsion, quantify the duration of the intervention and investigate the timely interaction of the different components of MPP. METHODS: Two bespoke right-handed measurement gloves (MG), with built in sensors, were designed and produced. The MG allowed the electronic real-time measurement of applied forces during MPP and transferred this data wirelessly to an integrated computer system. Sterile gloves were worn over the MG when used at the time of birth. The study was undertaken between January and December 2019. Singleton, term pregnant women having their first vaginal birth who provided a valid written consent were enrolled into this prospective pilot study. All deliveries were undertaken by one of two obstetricians experienced in MPP. RESULTS: Twenty women were enrolled. The mean duration of execution of MPP during the last contraction was 13.6 s. In 20% it lasted < 5 s. The overall mean values of the average and maximum forces of the thumb, index and middle fingers were 26.7 N; 25.5 N; 20.2 N and 34.3 N; 32.6 N; and 27.6 N respectively. The onset of fingers and thumb activity was simultaneous in 13 cases (65%), while in seven (35%) deliveries the middle finger's force activity was initiated later. CONCLUSIONS: MPP during fetal head expulsion happens over a short period of time. In the majority of cases the thumb and fingers actions started simultaneously. There were differences in the duration of application and the forces executed by the fingers and thumb between the two practitioners, however this was only significant for thumb measurements. The results obtained will aid in improving further MPP modeling studies to optimize the technique.
- Klíčová slova
- Computational modelling, Duration, Finnish method, Forces, Keys: Manual perineal protection, Physiology, Pressure, Vaginal delivery, Variability,
- MeSH
- benchmarking MeSH
- dospělí MeSH
- hlava MeSH
- lidé MeSH
- perineum fyziologie MeSH
- pilotní projekty MeSH
- prospektivní studie MeSH
- prsty ruky MeSH
- těhotenství MeSH
- vedení porodu přístrojové vybavení MeSH
- Check Tag
- dospělí MeSH
- lidé MeSH
- těhotenství MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH