BACKGROUND: Initial clinical studies of pulsed field ablation (PFA) to treat atrial fibrillation (AF) indicated a >90% durability rate of pulmonary vein isolation (PVI). However, these studies were largely conducted in single centers and involved a limited number of operators. The electrophysiological findings and outcomes in patients undergoing repeat ablation after an initial PF ablation for AF are incompletely understood. METHODS: In the MANIFEST-REDO study, we investigated patients who underwent repeat ablation due to clinical recurrence - AF or atrial tachycardia (AT) - following first-ever PVI with a pentaspline PFA catheter (Farawave; Boston Scientific Inc). RESULTS: At 22 centers, 427 patients (age 64±11 years; 37% female) were included. Of note, the recurrent arrhythmia leading to the repeat ablation was paroxysmal AF (51%), persistent AF (30%), or AT (19%). At the repeat procedure, the PV reconnection rates were: 30% (LSPV), 28% (LIPV), 33% (RSPV) and 32% (RIPV). In 45% of patients all PVs were durably isolated at the beginning of the repeat procedure, with the previous use of any imaging or mapping modality being univariately associated with durable PVI. After a post-redo follow-up period of 284 [90-366] days, the primary effectiveness endpoint (freedom from documented AF/AT lasting ≥30s after 3-month blanking without class I/III antiarrhythmic drugs or symptoms) was achieved in 65% of patients, with significant differences between groups (PAF 65% vs. PersAF 56% vs. AT 76%; p=0.04). Persistent AF as recurrent arrhythmia after the initial PFA ablation predicted AT/AF recurrence after repeat ablation (HR 1.241 (95% CI 1.534-1.005 CI); p=0.045). The procedural complication rate was 2.8%. CONCLUSION: In repeat procedures for AF/AT performed after an index procedure with PFA for AF, PV reconnections are not uncommon. Repeat procedures can be performed safely and with an acceptable subsequent success rate.
- Klíčová slova
- Atrial fibrillation, atrial tachycardia, electroporation, pulmonary vein isolation, pulsed field ablation,
- Publikační typ
- časopisecké články MeSH
AIMS: We report our single-centre experience of mid-term to long-term retrieval and reimplantation of a tine-based leadless pacemaker [Micra transcatheter pacing system (TPS)]. The TPS is a clinically effective alternative to transvenous single-chamber ventricular pacemakers. Whereas it is currently recommended to abandon the TPS at the end of device life, catheter-based retrieval may be favourable in specific scenarios. METHODS AND RESULTS: We report on nine consecutive patients with the implanted TPS who subsequently underwent transcatheter retrieval attempts. The retrieval system consists of the original TPS delivery catheter and an off-the-shelf single-loop 7 mm snare. The procedure was guided by fluoroscopy and intracardiac echocardiography. After an implantation duration of 3.1 ± 2.8 years (range 0.4-9.0), the overall retrieval success rate was 88.9% (8 of 9 patients). The mean procedure time was 89 ± 16 min, and the fluoroscopy time was 18.0 ± 6.6 min. No procedure-related adverse device events occurred. In the one unsuccessful retrieval, intracardiac echocardiography revealed that the TPS was partially embedded in the ventricular tissue surrounding the leadless pacemaker body in the right ventricle. After retrieval, three patients were reimplanted with a new TPS device. All implantations were successful without complications. CONCLUSION: A series of transvenous late retrievals of implanted TPS devices demonstrated safety and feasibility, followed by elective replacement with a new leadless pacing device or conventional transvenous pacing system. This provides a viable end-of-life management alternative to simple abandonment of this leadless pacemaker.
- Klíčová slova
- Leadless cardiac pacemaker, Leadless pacemaker reimplantation, Leadless pacemaker retrieval, Micra transcatheter pacing system,
- MeSH
- časové faktory MeSH
- design vybavení MeSH
- echokardiografie MeSH
- intervenční radiografie MeSH
- kardiostimulace umělá metody MeSH
- kardiostimulátor * MeSH
- lidé středního věku MeSH
- lidé MeSH
- odstranění implantátu * metody MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- srdeční katetrizace * metody přístrojové vybavení MeSH
- srdeční katétry MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři nad 80 let MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: During pulsed field ablation (PFA), electrode-tissue proximity optimizes lesion quality. A novel "single-shot" map-and-ablate spherical multielectrode PFA array catheter that is able to verify electrode-tissue contact was recently studied in a first-in-human trial of atrial fibrillation (AF). OBJECTIVE: The aim of this study was to report lesion durability data, safety, and 12-month effectiveness outcomes. METHODS: The spherical PFA catheter, an all-in-one mapping and ablation system, was used to render anatomy and to deliver biphasic pulses (ungated 1.7 kV pulses; ∼40 seconds/application). Ablation sites included pulmonary veins (PVs) and, in selected patients, posterior wall and mitral isthmus. Follow-up was invasive remapping at ∼3 months, electrocardiograms, Holter monitoring at 6 and 12 months, and symptomatic and scheduled transtelephonic monitoring. The primary and secondary efficacy end points were acute PV isolation (PVI), PVI durability, and atrial arrhythmia recurrence. RESULTS: In the 48-patient AF cohort (paroxysmal, 48%; persistent, 52%), lesion sets included PVI (n = 48; 1.2 applications/PV), posterior wall (n = 20; 3.6 applications/posterior wall), and mitral isthmus (n = 11; 2.9 applications/mitral isthmus). Lesions were acutely successful for all 187 of 187 PVs (100%), 20 of 20 posterior walls (100%), and 10 of 11 mitral isthmuses (91%). Pulse delivery time, left atrial catheter dwell time, and procedure time were 61.5 ± 32.8 seconds, 53.9 ± 26.5 minutes, and 87.8 ± 29.8 minutes, respectively. Remapping (43/48 patients [89.5%]) revealed that 158 of 169 PVs (93.5%) were durably isolated. The only complication was a drug-responsive pericarditis. The 1-year Kaplan-Meier estimates of freedom from atrial arrhythmia were 84.2% (paroxysmal AF) and 80.0% (persistent AF). CONCLUSION: The single-shot spherical array PFA catheter can safely achieve durable lesions, translating into good clinical efficacy.
- Klíčová slova
- Atrial fibrillation, Catheter ablation, Pulmonary vein isolation, Pulsed field ablation, Spherical array catheter,
- MeSH
- časové faktory MeSH
- design vybavení MeSH
- elektrokardiografie ambulantní metody MeSH
- fibrilace síní * chirurgie patofyziologie MeSH
- katetrizační ablace * metody přístrojové vybavení MeSH
- lidé středního věku MeSH
- lidé MeSH
- následné studie MeSH
- převodní systém srdeční patofyziologie MeSH
- recidiva MeSH
- senioři MeSH
- venae pulmonales * chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- klinické zkoušky MeSH
- práce podpořená grantem MeSH
BACKGROUND: Electrographic flow (EGF) mapping enables full spatiotemporal reconstruction of organized wavefront propagation to identify extrapulmonary vein sources of atrial fibrillation (AF). OBJECTIVES: FLOW-AF (A Randomized Controlled Study to Evaluate the Reliability of the Ablacon Electrographic FLOW [EGF] Algorithm Technology [Ablamap Software] to Identify AF Sources and Guide Ablation Therapy in Patients With Persistent Atrial Fibrillation) was multicenter, randomized controlled study of EGF mapping to: 1) stratify a nonparoxysmal AF population undergoing redo ablation; 2) guide ablation of these extrapulmonary vein AF sources; and 3) improve AF recurrence outcomes. METHODS: FLOW-AF enrolled persistent atrial fibrillation (PerAF)/long-standing PerAF patients undergoing redo ablation at 4 centers. One-minute EGF maps were recorded from standardized biatrial basket positions. Patients with source activity ≥26.5% were randomized 1:1 to PVI + EGF-guided ablation vs PVI only; patients without sources ≥26.5% threshold were not randomized. Follow-up and electrocardiographic monitoring occurred at 3, 6, and 12 months. RESULTS: We enrolled 85 patients (age 65.6 ± 9.3 years, 37% female, 24% long-standing PerAF). Thirty-four (40%) patients had no sources greater than threshold; at least 1 source greater than threshold was present in 46 (60%) (EGF-guided ablation, n = 22; control group, n = 26). Patients with sources were older (68.2 vs 62.6 years; P = 0.005) with higher CHA2DS2-VASc scores (2.8 vs 1.9; P = 0.001). The freedom from safety events was 97.2%, and 95% of EGF-identified sources were successfully ablated. In randomized patients, AF-free survival at 12 months was 68% for EGF-guided ablation vs 17% for the control group (P = 0.042); freedom from AF/atrial tachycardia/atrial flutter at 12 months was 51% vs 14% (P = 0.103), respectively. CONCLUSIONS: In nonparoxysmal AF patients undergoing redo ablation, EGF mapping identified AF sources in 60% of patients, and could be successfully ablated in 95%. Compared with PVI alone, PVI + source ablation improved AF-free survival by 51% on an absolute basis. (FLOW-AF: A Study to Evaluate the Ablacon Electrographic FLOW EGF Technology [A Randomized Controlled Study to Evaluate the Reliability of the Ablacon Electrographic FLOW (EGF) Algorithm Technology (Ablamap Software) to Identify AF Sources and Guide Ablation Therapy in Patients With Persistent Atrial Fibrillation]; NCT04473963).
- Klíčová slova
- basket catheter, electrographic flow mapping, panoramic mapping, persistent atrial fibrillation,
- MeSH
- algoritmy MeSH
- elektrofyziologické techniky kardiologické metody MeSH
- elektrokardiografie MeSH
- fibrilace síní * chirurgie patofyziologie MeSH
- katetrizační ablace * metody škodlivé účinky MeSH
- lidé středního věku MeSH
- lidé MeSH
- reoperace statistika a číselné údaje MeSH
- senioři MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
- randomizované kontrolované studie MeSH
AIMS: Wearable cardioverter-defibrillators (WCDs) are indicated in patients at risk of sudden cardiac arrest who are not immediate candidates for implantable defibrillator therapy. Limitations of existing WCDs include poor compliance and high false alarm rates. The Jewel is a novel patch-WCD (P-WCD) that addresses these limitations with an adhesive-based design for near-continuous wear and a machine learning algorithm designed to minimize inappropriate detections. This was a first-in-human study of the Jewel P-WCD conducted in an electrophysiology (EP) lab to determine the safety and effectiveness of the device in terminating ventricular tachycardia/ventricular fibrillation (VT/VF) with a single shock. The aim was to evaluate the safety and effectiveness of terminating VT/VF with a single shock using the Jewel P-WCD. METHODS AND RESULTS: This was a first-in-human, prospective, single-arm, single-centre study in patients scheduled for an EP procedure in which VT/VF was expected to either spontaneously occur or be induced. The Jewel P-WCD was placed on consented patients; upon confirmation of VT/VF, a single shock (150 J) was delivered via the device. A group sequential design and Pocock alpha spending function was used to measure the observed proportion of successful VT/VF single-shock terminations. The endpoint was achieved if the lower confidence limit exceeded the performance goal of 62%, using a one-sided lower 97.4% exact confidence bound. Of 18 eligible subjects, 16 (88.9%, 97.4% confidence bound: 65.4%) were successfully defibrillated with a single shock, exceeding the primary endpoint performance goal with no adverse events. CONCLUSION: This first-in-human evaluation of the Jewel P-WCD demonstrated the safety and effectiveness of terminating VT/VF. CLINICAL TRIAL REGISTRATION: URL: https://clinicaltrials.gov/; Unique identifier: NCT05490459.
- Klíčová slova
- Sudden cardiac arrest, Ventricular arrhythmia, Wearable cardioverter-defibrillator,
- MeSH
- defibrilátory * MeSH
- design vybavení MeSH
- dospělí MeSH
- elektrická defibrilace * přístrojové vybavení škodlivé účinky MeSH
- fibrilace komor * terapie diagnóza MeSH
- komorová tachykardie * terapie diagnóza patofyziologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- náhlá srdeční smrt prevence a kontrola MeSH
- nositelná elektronika * MeSH
- prospektivní studie MeSH
- senioři MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- klinická studie MeSH
Pulsed field ablation (PFA) is an emerging technology for the treatment of atrial fibrillation (AF), for which pre-clinical and early-stage clinical data are suggestive of some degree of preferentiality to myocardial tissue ablation without damage to adjacent structures. Here in the MANIFEST-17K study we assessed the safety of PFA by studying the post-approval use of this treatment modality. Of the 116 centers performing post-approval PFA with a pentaspline catheter, data were received from 106 centers (91.4% participation) regarding 17,642 patients undergoing PFA (mean age 64, 34.7% female, 57.8% paroxysmal AF and 35.2% persistent AF). No esophageal complications, pulmonary vein stenosis or persistent phrenic palsy was reported (transient palsy was reported in 0.06% of patients; 11 of 17,642). Major complications, reported for ~1% of patients (173 of 17,642), were pericardial tamponade (0.36%; 63 of 17,642) and vascular events (0.30%; 53 of 17,642). Stroke was rare (0.12%; 22 of 17,642) and death was even rarer (0.03%; 5 of 17,642). Unexpected complications of PFA were coronary arterial spasm in 0.14% of patients (25 of 17,642) and hemolysis-related acute renal failure necessitating hemodialysis in 0.03% of patients (5 of 17,642). Taken together, these data indicate that PFA demonstrates a favorable safety profile by avoiding much of the collateral damage seen with conventional thermal ablation. PFA has the potential to be transformative for the management of patients with AF.
- MeSH
- fibrilace síní * chirurgie terapie MeSH
- katetrizační ablace * škodlivé účinky metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- pooperační komplikace epidemiologie etiologie MeSH
- senioři MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- multicentrická studie MeSH
BACKGROUND: Atrial fibrillation (AF) and heart failure (HF) coexist, increasing morbidity and mortality. Studies have demonstrated improved outcomes following AF ablation in HF patients with reduced ejection fraction (EF). OBJECTIVE: This study sought to assess the outcomes of pulsed field ablation (PFA) in HF. METHODS: MANIFEST-PF (Multi-National Survey on the Methods, Efficacy, and Safety on the Post-Approval Clinical Use of Pulsed Field Ablation) is a multicenter, patient-level registry of consecutive patients undergoing PFA for paroxysmal AF or persistent AF (PerAF). In this substudy, patients were stratified as no history of HF (no-HF), HF with preserved EF (HFpEF) (left ventricular EF of ≥50%) or HF with reduced/mildly reduced EF (HFmr/rEF) (left ventricular EF of <50%). The primary effectiveness and safety endpoints were freedom from documented atrial arrhythmias lasting ≥30 seconds and major adverse events, respectively. RESULTS: Of the 1,381 patients, 85% (n = 1,174) were no-HF, 6.2% (n = 87) were HFpEF, and 8.6% (n = 120) were HFmr/rEF. No-HF patients had less PerAF than patients with HF (P < 0.001), with no difference between HF subtypes (P = >0.99). The 1-year freedom from atrial arrhythmia was significantly higher in no-HF patients than in those with HFpEF or HFmr/rEF (79.9%, 71.3%, and 67.5%, respectively; P < 0.001) but similar between patients with HFmr/rEF and HFpEF (P = 0.26). However, there was no significant difference in freedom from atrial arrhythmia among patients with no-HF vs HFpEF vs HFmr/rEF for those with paroxysmal AF (82.8%, 82.4%, and 71.7%, respectively; P = 0.09) and PerAF (73.3%, 64.2%, and 64.9%, respectively; P = 0.14). Major adverse event rates were similar between the no-HF, HFpEF, and HFmr/rEF groups (1.9%, 0%, and 2.5%, respectively). CONCLUSIONS: PFA appears to be potentially safe and effective in AF patients with HF. Freedom from atrial arrhythmia post-PFA was higher in patients without a history of HF, with no significant difference between HF subtypes.
- Klíčová slova
- HFpEF, HFrEF, atrial fibrillation, heart failure, pulsed field ablation,
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Atrial fibrillation (AF) and heart failure (HF) coexist, increasing morbidity and mortality. Studies have demonstrated improved outcomes following AF ablation in HF patients with reduced ejection fraction (EF). OBJECTIVE: To assess the outcomes of pulsed-field ablation (PFA) in HF. METHODS: MANIFEST-PF is a multicenter patient-level registry of consecutive patients undergoing PFA for paroxysmal (PAF) or persistent AF (PerAF). In this sub-study, patients were stratified as: no history of HF (no-HF), HF with preserved EF (HFPEF; LVEF≥50%) or HF with reduced/mildly-reduced EF (HFMR/REF; LVEF<50%). The primary effectiveness and safety endpoints were freedom from documented atrial arrhythmias lasting ≥30s and major adverse events (MAEs), respectively. RESULTS: Of the 1,381 patients, 85% (n=1,174) were no-HF, 6.2% (n=87) were HFPEF, and 8.6% (n=120) were HFMR/REF. No-HF patients had less PerAF than patients with HF (p<0.001), with no difference between HF subtypes (p=1.00). The 1-year freedom from atrial arrhythmia was significantly higher in no-HF than with HFPEF or HFMR/REF (79.9%, 71.3%, 67.5%, p<0.001), but similar between HFMR/REF and HFPEF (p=0.26). However, there was no significant difference in freedom from atrial arrhythmia among patients with no-HF vs HFPEF vs HFMR/REF for those with PAF (82.8%/82.4%/71.7%, p=0.09) and PerAF (73.3%, 64.2%, and 64.9%, p=0.14.MAE rates were similar between the no-HF, HFPEF and HFMR/REF groups (1.9%, 0%, and 2.5%, respectively). CONCLUSION: PFA appears to be potentially safe and effective in AF patients with HF. Freedom from atrial arrhythmia post-PFA was higher in patients without a history of HF, with no significant difference between HF subtypes.
- Klíčová slova
- Atrial fibrillation, HFPEF, HFREF, heart failure, pulsed field ablation,
- Publikační typ
- časopisecké články MeSH
BACKGROUND: In treating atrial fibrillation, pulsed-field ablation (PFA) has comparable efficacy to conventional thermal ablation, but with important safety advantages: no esophageal injury or pulmonary vein stenosis, and rare phrenic nerve injury. However, when PFA is delivered in proximity to coronary arteries using a pentaspline catheter, which generates a broad electrical field, severe vasospasm can be provoked. OBJECTIVES: The authors sought to study the vasospastic potential of a focal PFA catheter with a narrower electrical field and develop a preventive strategy with nitroglycerin. METHODS: During atrial fibrillation ablation, a focal PFA catheter was used for cavotricuspid isthmus ablation. Angiography of the right coronary artery (some with fractional flow reserve measurement) was performed before, during, and after PFA. Beyond no nitroglycerin (n = 5), and a few testing strategies (n = 8), 2 primary nitroglycerin administration strategies were studied: 1) multiple boluses (3-2 mg every 2 min) into the right atrium (n = 10), and 2) a bolus (3 mg) into the right atrium with continuous peripheral intravenous infusion (1 mg/min; n = 10). RESULTS: Without nitroglycerin, cavotricuspid isthmus ablation provoked moderate-severe vasospasm in 4 of 5 (80%) patients (fractional flow reserve 0.71 ± 0.08). With repetitive nitroglycerin boluses, severe spasm did not occur, and mild-moderate vasospasm occurred in only 2 of 10 (20%). Using the bolus + infusion strategy, severe and mild-moderate spasm occurred in 1 and 3 of 10 patients (aggregate 40%). No patient had ST-segment changes. CONCLUSIONS: Ablation of the cavotricuspid isthmus using a focal PFA catheter routinely provokes right coronary vasospasm. Pretreatment with high doses of parenteral nitroglycerin prevents severe spasm.
- Klíčová slova
- atrial fibrillation, catheter ablation, cavotricuspid isthmus, cavotricuspid isthmus ablation, nitroglycerin, pulsed field ablation, spasm, vasospasm,
- MeSH
- fibrilace síní * chirurgie MeSH
- katetrizační ablace * metody škodlivé účinky MeSH
- koronární angiografie MeSH
- koronární cévy účinky léků chirurgie patofyziologie MeSH
- koronární vazospasmus * prevence a kontrola MeSH
- lidé středního věku MeSH
- lidé MeSH
- nitroglycerin * aplikace a dávkování terapeutické užití MeSH
- senioři MeSH
- vazodilatancia terapeutické užití aplikace a dávkování MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- nitroglycerin * MeSH
- vazodilatancia MeSH
- MeSH
- chronická nemoc MeSH
- katetrizační ablace škodlivé účinky MeSH
- koronární angiografie MeSH
- koronární cévy diagnostické zobrazování MeSH
- koronární vazospasmus * patofyziologie etiologie diagnostické zobrazování MeSH
- lidé MeSH
- nemoci koronárních tepen chirurgie patofyziologie MeSH
- Check Tag
- lidé MeSH
- Publikační typ
- dopisy MeSH
- kazuistiky MeSH