Transcatheter non-acute retrieval of the tine-based leadless ventricular pacemaker
Language English Country Great Britain, England Media print
Document type Journal Article
Grant support
Ministry of Health
00023884
NHH
CEP Register
PubMed
39374848
PubMed Central
PMC11503947
DOI
10.1093/europace/euae256
PII: 7815054
Knihovny.cz E-resources
- Keywords
- Leadless cardiac pacemaker, Leadless pacemaker reimplantation, Leadless pacemaker retrieval, Micra transcatheter pacing system,
- MeSH
- Time Factors MeSH
- Equipment Design MeSH
- Echocardiography MeSH
- Radiography, Interventional MeSH
- Cardiac Pacing, Artificial methods MeSH
- Pacemaker, Artificial * MeSH
- Middle Aged MeSH
- Humans MeSH
- Device Removal * methods MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Cardiac Catheterization * methods instrumentation MeSH
- Cardiac Catheters MeSH
- Treatment Outcome MeSH
- Check Tag
- Middle Aged MeSH
- Humans MeSH
- Male MeSH
- Aged, 80 and over MeSH
- Aged MeSH
- Female MeSH
- Publication type
- Journal Article MeSH
AIMS: We report our single-centre experience of mid-term to long-term retrieval and reimplantation of a tine-based leadless pacemaker [Micra transcatheter pacing system (TPS)]. The TPS is a clinically effective alternative to transvenous single-chamber ventricular pacemakers. Whereas it is currently recommended to abandon the TPS at the end of device life, catheter-based retrieval may be favourable in specific scenarios. METHODS AND RESULTS: We report on nine consecutive patients with the implanted TPS who subsequently underwent transcatheter retrieval attempts. The retrieval system consists of the original TPS delivery catheter and an off-the-shelf single-loop 7 mm snare. The procedure was guided by fluoroscopy and intracardiac echocardiography. After an implantation duration of 3.1 ± 2.8 years (range 0.4-9.0), the overall retrieval success rate was 88.9% (8 of 9 patients). The mean procedure time was 89 ± 16 min, and the fluoroscopy time was 18.0 ± 6.6 min. No procedure-related adverse device events occurred. In the one unsuccessful retrieval, intracardiac echocardiography revealed that the TPS was partially embedded in the ventricular tissue surrounding the leadless pacemaker body in the right ventricle. After retrieval, three patients were reimplanted with a new TPS device. All implantations were successful without complications. CONCLUSION: A series of transvenous late retrievals of implanted TPS devices demonstrated safety and feasibility, followed by elective replacement with a new leadless pacing device or conventional transvenous pacing system. This provides a viable end-of-life management alternative to simple abandonment of this leadless pacemaker.
Cardiology Department Na Homolce Hospital Roentgenova 37 2 15030 Prague Czech Republic
Department of Cardiology Icahn School of Medicine at Mount Sinai New York NY USA
See more in PubMed
Defaye P, Biffi M, El-Chami M, Boveda S, Glikson M, Piccini J et al. Cardiac pacing and lead devices management: 25 years of research at EP Europace journal. Europace 2023;25:euad202. PubMed PMC
Boveda S, Higuera L, Longacre C, Wolff C, Wherry K, Stromberg K et al. Two-year outcomes of leadless vs. transvenous single-chamber ventricular pacemaker in high-risk subgroups. Europace 2023;25:1041–50. PubMed PMC
Reynolds D, Duray GZ, Omar R, Soejima K, Neuzil P, Zhang S et al. A leadless intracardiac transcatheter pacing system. N Engl J Med 2016;374:533–41. PubMed
Reddy VY, Exner DV, Cantillon DJ, Doshi R, Bunch TJ, Tomassoni GF et al. Percutaneous implantation of an entirely intracardiac leadless pacemaker. N Engl J Med 2015;373:1125–35. PubMed
Roberts PR, Clementy N, Samadi FA, Garweg C, Martinez-Sande JL, Iacopino S et al. A leadless pacemaker in the real-world setting: the Micra transcatheter pacing system post-approval registry. Heart Rhythm 2017;14:1375–9. PubMed
Reddy VY, Miller MA, Knops RE, Neuzil P, Defaye P, Jung W et al. Retrieval of the leadless cardiac pacemaker: a multicenter experience. Circ Arrhythm Electrophysiol 2016;9:e004626. PubMed
Lakkireddy D, Knops R, Atwater B, Neuzil P, Ip J, Gonzalez E et al. A worldwide experience of the management of battery failures and chronic device retrieval of the Nanostim leadless pacemaker. Heart Rhythm 2017;14:1756–63. PubMed
Minami K, Shtëmbari J, Petrů J, Chovanec M, Funasako M, Hála P et al. Successful retrieval of a 4-year-old micra transcatheter pacemaker system in a patient with leadless biventricular pacing therapy. JACC Case Rep 2020;2:2249–52. PubMed PMC
Morita J, Kondo Y, Hachinohe D, Kitai T, Fujita T. Retrieval of an infectious leadless pacemaker with vegetation. J Arrhythmia 2023;39:71–3. PubMed PMC
Patel H, Harrell S, Hreibe H, Sharkawi M, AlJaroudi W. A rare case of persistent bacteremia: leadless Micra pacemaker endocarditis. Case Rep Cardiol 2023;2023:8326020. PubMed PMC
Nozoe M, Yoshida D, Nagatomo D, Suematsu N, Kubota T, Okabe M et al. Successful percutaneous retrieval of a Micra transcatheter pacing system at 8 weeks after implantation. J Arrhythm 2018;34:653–5. PubMed PMC
Fichtner S, Estner HL, Näbauer M, Hausleiter J. Percutaneous extraction of a leadless Micra after dislocation: a case report. Eur Heart J Case Rep 2019;13:113. PubMed PMC
Grubman E, Ritter P, Ellis CR, Giocondo M, Augostini R, Neuzil P et al. To retrieve, or not to retrieve: system revisions with the Micra transcatheter pacemaker. Heart Rhythm 2017;14:1801–6. PubMed
Sheldon T, Escalante K, Fagan D. Device longevity and AV synchrony algorithm modeling of a leadless pacemaker family: a virtual patient analysis. January 2023. Medtronic data on file. https://europe.medtronic.com/xd-en/healthcare-professionals/products/cardiac-rhythm/pacemakers/micra-vr2.html (17 October 2024, date last accessed).
Breeman K, Dijkshoorn L, Beurskens N, Wilde A, Tjong F, Knops R. Real-world long-term battery longevity of leadless pacemakers. Eur Heart J 2022;43:ehac544.486. PubMed
Santobuono VZ, Basile P, Carella MC, Pomarico F, Favale S, Ciccone MM et al. Percutaneous extraction of a Micra AV transcatheter pacing system due to a rare sudden battery failure after 19 months from implantation: a first experience worldwide. Pacing Clin Electrophysiol 2024;47:256–9. PubMed
Karim S, Abdelmessih M, Marieb M, Reiner E, Grubman E. Extraction of a Micra transcatheter pacing system: first-in-human experience. HeartRhythm Case Rep 2016;2:60–2. PubMed PMC
Curnis A, Cerini M, Mariggiò D, Mitacchione G, Giacopelli D, Inama L et al. First-in-human retrieval of chronically implanted Micra transcatheter pacing system. Pacing Clin Electrophysiol 2019;42:1063–5. PubMed
De Filippo P, Malanchini G, Leidi C, Racheli M, Ferrari G, Senni M et al. Elective replacement of a 4-year-old leadless pacemaker: new approach for end-of-life management. J Cardiovasc Electrophysiol 2021;32:1171–3. PubMed
Callahan TD 4th, Wilkoff BL. Extraction of a 5-year-old leadless pacemaker using a competing manufacturer’s removal tool. HeartRhythm Case Rep 2023;9:441–4. PubMed PMC
Mitacchione G, Schiavone M, Gasperetti A, Arabia G, Breitenstein A, Cerini M et al. Outcomes of leadless pacemaker implantation following transvenous lead extraction in high-volume referral centers: real-world data from a large international registry. Heart Rhythm 2023;20:395–404. PubMed
Vamos M, Honold J, Duray GZ, Hohnloser SH. MICRA leadless pacemaker on autopsy. JACC Clin Electrophysiol 2016;2:636–7. PubMed
Kypta A, Blessberger H, Lichtenauer M, Steinwender C. Complete encapsulation of a leadless cardiac pacemaker. Clin Res Cardiol 2015;105:94. PubMed
Gabrah K, Mahtani AU, Nair DG. Micra extraction out to 4.5 years. Card Electrophysiol Clin 2024;16:149–55. PubMed
Afzal MR, Jamal SM, Son JH, Chung JH, Gabriels J, Okabe T et al. Tips and tricks for safe retrieval of tine-based leadless pacemakers. J Innov Cardiac Rhythm Manage 2021;12:4562–8. PubMed PMC
Kiani S, Merchant FM, El-Chami MF. Extraction of a 4-year-old leadless pacemaker with a tine-based fixation. HeartRhythm Case Rep 2019;5:424–5. PubMed PMC
Chmielewska-Michalak L, Gwizdała A, Ciepłucha A, Katarzyńska-Szymańska A, Ochotny R, Lesiak M et al. Extraction of a 6-year-old leadless pacemaker (MICRA transcatheter pacing system) using commercially available removal tools: a case report. J Cardiovasc Electrophysiol 2024;35:1706–9. PubMed
Neuzil P, Petrů J, Šedivá L, Chovanec M, Šorf J, Funasako M. Retrieval and replacement feasibility of 7-year-old implanted leadless pacemaker with tines fixation. HeartRhythm Case Rep 2024;10:2–5. PubMed PMC
Neuzil P, Petru J, Chovanec M, Hala P, Sediva L, Reddy VY. Retrieval and replacement of a helix-fixation leadless pacemaker at 9 years post-implant. HeartRhythm Case Rep 2023;9:258–62. PubMed PMC