Persistent and long-standing persistent atrial fibrillation evolves from complex arrhythmogenic substrate and sources. Multiple studies have shown improved freedom from arrhythmia recurrences if sinus rhythm had been restored during the index ablation; however, such harder procedural endpoint requires laborious stepwise approach almost invariably pursuing non-pulmonary-vein sources. Longer-term conversion of persistent atrial fibrillation into sinus rhythm is associated with significant improvement in major indices of hemodynamic and functional status; these indices also represent major predictors of cardiovascular mortality. Optimal ablation techniques and strategies preserving most of the individual potential for functional improvement need to be established.
- Klíčová slova
- Atrial Fibrillation, Catheter Ablation, Long-Standing Persistent, Persistent,
- Publikační typ
- časopisecké články MeSH
- přehledy MeSH
BACKGROUND: Hybrid ablation (i.e., a combination of a thoracoscopic surgical ablation followed by a catheter ablation) is a treatment option for patients with non-paroxysmal atrial fibrillation (AF). Despite its promising efficacy, it is a surgical procedure with a relatively high risk of complications that could affect the quality of life (QoL) of patients, even when sinus rhythm is restored. OBJECTIVE: To describe changes in the QoL of patients with non-paroxysmal AF before and after a hybrid ablation. METHODS: Patients after hybrid ablation for persistent or long-standing persistent AF were prospectively studied. Follow-up visits were scheduled at 1, 3, 6, 9, and 12 months. The maintenance of SR was assessed using 1-week Holter recordings at 6 and 12 months and 24-h Holter recordings at 3 and 9 months, or via an implantable loop recorder. QoL was assessed using the Atrial Fibrillation Effect on Quality-of-life (AFEQT) and the EuroQoL-5Dimensions (EQ-5D) questionnaires before and 12 months after ablation. RESULTS: Seventy-five patients (49 men, age 62.9 ± 8.45 years, 48 (64%) with long-standing persistent AF) were enrolled. Fifty-two (69.3%, SR group) were AF-free during the 12-month follow-up, 16 (21.3%, PAROX group) had only paroxysms of AF after ablation, and 7 (9.3%, PERM group) were on rate control due to permanent AF reoccurrence. The AFEQT score increased significantly in the SR group from 59.9 ± 19.4 to 91.4 ± 10.8 (p < 0.001), and in the PAROX group from 58.8 ± 19.0 to 81.5 ± 14.1 (p = 0.002) but remained unchanged in the PERM group (44.6 ± 7.5 vs. 47.4 ± 5.5, p = 0.24). The EQ-5D score significantly decreased in the descriptive part (from 7.90 ± 2.61 to 6.64 ± 1.90, p = 0.0001) and increased on the visual analog scale (from 63.56 ± 19.11 to 79.30 ± 16.9, p < 0.0001) in the SR group. In the PAROX group, no significant change was present on either the descriptive part (p = 0.3) or in the visual analog scale (p = 0.48). Similarly, no significant changes were present on either the descriptive part (p = 0.93) or the visual analog scale (p = 0.4) in the PERM group. CONCLUSION: The QoL of patients with non-paroxysmal AF and patients with AF paroxysms, after successful hybrid ablation, improved significantly in patients with SR. No significant improvement was present in patients on rate control after an unsuccessful ablation.
- Klíčová slova
- Atrial fibrillation, Hybrid ablation, Long-standing persistent, Persistent, Versapolar device,
- MeSH
- elektrokardiografie ambulantní MeSH
- fibrilace síní chirurgie MeSH
- katetrizační ablace metody MeSH
- kvalita života * MeSH
- lidé středního věku MeSH
- lidé MeSH
- prospektivní studie MeSH
- průzkumy a dotazníky MeSH
- torakoskopie * MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
AIMS: Identifying patients who benefit from restored sinus rhythm (SR) would optimize the selection of candidates for ablation of long-standing persistent atrial fibrillation (LSPAF). This prospective study sought to identify the hitherto unknown factors associated with global functional improvement after successful radiofrequency catheter ablation of LSPAF. METHODS AND RESULTS: In 171 LSPAF patients (84% of the total consecutive 203 patients) who were examined in SR 12 months after ablation, the individual per cent change from baseline value in maximum oxygen consumption at exercise test (VO2 max), left ventricular ejection fraction (LVEF), N-terminal prohormone of brain natriuretic peptide (NT-proBNP), and five-dimensional descriptive system (EQ-5D) of quality-of-life questionnaire were classified in quartiles by 0 (worse) to 3 (best) grades. The individual grades were summed into a composite score (SCORE, 0 … 12) reflecting global functional improvement. Significant improvement in VO2 max (3.4 ± 4.7 mL/kg/min), LVEF (7.5 ± 9.1%), NT-proBNP (-861 ± 809 pg/mL), and EQ-5D (0.7 ± 0.12) was observed (all P < 0.0001). On multivariable analysis, younger age (P = 0.001), male gender (P = 0.02), timely post-ablation left atrial appendage (LAA) outflow (P = 0.005) with improvement in outflow velocity (P = 0.0002), and withdrawal of Class I/III antiarrhythmic drugs (P < 0.05) were positively and independently correlated with the SCORE. CONCLUSIONS: Younger male patients benefited most from catheter ablation of LSPAF. Delayed or non-improved LAA outflow and inability to discontinue Class I/III antiarrhythmic medication reduced the post-ablation functional improvement.
- Klíčová slova
- Atrial fibrillation, Catheter ablation, Long-standing persistent, Outcome,
- MeSH
- antiarytmika terapeutické užití MeSH
- biologické markery krev MeSH
- časové faktory MeSH
- dospělí MeSH
- fibrilace síní diagnóza patofyziologie chirurgie MeSH
- funkce levé komory srdeční * MeSH
- katetrizační ablace * škodlivé účinky MeSH
- kvalita života MeSH
- lidé středního věku MeSH
- lidé MeSH
- multivariační analýza MeSH
- natriuretický peptid typu B krev MeSH
- obnova funkce MeSH
- peptidové fragmenty krev MeSH
- prospektivní studie MeSH
- průzkumy a dotazníky MeSH
- registrace MeSH
- rizikové faktory MeSH
- rozdělení chí kvadrát MeSH
- senioři MeSH
- sexuální faktory MeSH
- spotřeba kyslíku MeSH
- srdce - funkce levé síně * MeSH
- tepový objem MeSH
- tolerance zátěže * MeSH
- věkové faktory MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- Názvy látek
- antiarytmika MeSH
- biologické markery MeSH
- natriuretický peptid typu B MeSH
- peptidové fragmenty MeSH
- pro-brain natriuretic peptide (1-76) MeSH Prohlížeč
AIMS: Clinical benefit from ablation for long-standing persistent atrial fibrillation has remained unknown. We hypothesized that successful ablation of long-standing persistent atrial fibrillation would improve haemodynamics, functional status, and quality of life. METHODS AND RESULTS: A total of 160 patients (aged 59 ± 9 years, 23% females) undergoing ablation of long-standing (median of 28 months) persistent atrial were enrolled in this prospective study. Morphological and functional echocardiographic parameters, N-terminal prohormone of brain natriuretic peptide (NT-proBNP), maximum oxygen consumption during exercise test (VO2 max), and quality of life were assessed at baseline and 1 year after the ablation. At the 1-year follow-up visit, 81% patients were examined in sinus rhythm (after repeat ablation in 38% patients). Left atrial appendage outflow velocity increased from 44 ± 20 to 58 ± 23 cm/s, left ventricular ejection fraction from 54 ± 9 to 59 ± 5%, and VO2 max from 20.4 ± 6.4 to 23.7 ± 8.1 mL/kg/min; NT-proBNP decreased from median 897 (interquartile range 603-1424) to 230 (interquartile range 120-420) pg/mL (all P < 0.0001). These beneficial effects of ablation were predominantly associated with the presence of sinus rhythm. Quality of life (range 0-100) increased significantly (EQ-5D index: from 68.8 ± 12.5 to 75.4 ± 14.4; EQ-VAS score: from 62.8 ± 13.2 to 70.6 ± 13.8; both P < 0.0001). CONCLUSION: Ablation of long-standing persistent atrial fibrillation was associated with significant recovery of haemodynamics and exercise capacity that projected onto the long-term improvement in quality of life.
- Klíčová slova
- Atrial fibrillation, Catheter ablation, Long-standing persistent, Outcome,
- MeSH
- chronická nemoc MeSH
- činnosti denního života psychologie MeSH
- deprese etiologie psychologie MeSH
- dospělí MeSH
- fibrilace síní diagnóza psychologie chirurgie MeSH
- katetrizační ablace škodlivé účinky psychologie MeSH
- kvalita života psychologie MeSH
- lidé středního věku MeSH
- lidé MeSH
- longitudinální studie MeSH
- obnova funkce * MeSH
- pooperační komplikace etiologie psychologie MeSH
- prospektivní studie MeSH
- senioři MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- randomizované kontrolované studie MeSH
BACKGROUND: The impact of restoring sinus rhythm (SR) by initial ablation in patients with long-standing persistent atrial fibrillation (LSPAF) is not fully established. OBJECTIVE: The purpose of this study was to investigate the prognostic value of SR restoration at the initial procedure and arrhythmia noninducibility at the final repeat procedure for long-term outcome. METHODS: A total of 203 patients (22% female; age 59 ± 9 years) underwent stepwise catheter ablation for LSPAF. RESULTS: The procedural end-point of SR restoration was achieved in 50% of patients. During follow-up (median 48 months) and after 1.7 procedures per patient, 72% of patients were free from arrhythmia off antiarrhythmic drugs. Failure to restore SR was independently predicted by left atrial (LA) long-axis diameter ≥68 mm (relative risk [RR] 1.55, P = .03], proportion of high-voltage LA sites <20% (RR 1.62, P = .02), and left atrial appendage (LAA) atrial fibrillation cycle length (AFCL) <155 ms (RR 1.5, P = .05). Arrhythmia recurrence after the initial procedure was predicted by SR nonrestoration (RR 2.99, P <.000001) and LAA AFCL ≥155 ms (RR 1.90, P = .0002). Arrhythmia recurrence after the final procedure was predicted by SR nonrestoration at the initial procedure (RR 2.83, P = .0007), persistent AF duration ≥24 months (RR 2.74, P = .002), LAA outflow velocity <40 cm/s (RR 2.21, P = .006), and LAA AFCL ≥155 ms (RR 1.92, P = .02). In 115 patients with repeat procedure(s), failure to achieve arrhythmia noninducibility at the final procedure (19% of patients) was associated with arrhythmia recurrence (RR 8.9, P < .000001). CONCLUSION: SR restoration at the initial procedure and arrhythmia noninducibility at the last repeat procedure were major predictors of arrhythmia-free outcome after ablation for LSPAF.
- Klíčová slova
- Atrial fibrillation, Long-standing persistent atrial fibrillation, Noninducibility, Outcome, Sinus rhythm restoration,
- MeSH
- antiarytmika terapeutické užití MeSH
- čas MeSH
- elektrofyziologické techniky kardiologické MeSH
- fibrilace síní * diagnóza farmakoterapie epidemiologie chirurgie MeSH
- hodnocení rizik MeSH
- katetrizační ablace * škodlivé účinky metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- pooperační komplikace * diagnóza epidemiologie terapie MeSH
- přežití po terapii bez příznaků nemoci MeSH
- prognóza MeSH
- prospektivní studie MeSH
- recidiva MeSH
- registrace MeSH
- reoperace MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- Geografické názvy
- Česká republika epidemiologie MeSH
- Názvy látek
- antiarytmika MeSH
PURPOSE: Hybrid ablation of atrial fibrillation (AF) is a promising treatment strategy for patients with non-paroxysmal AF, although, data regarding mid-term outcomes are limited. METHODS: Patients with persistent or long-standing persistent AF were enrolled. Initially, a thoracoscopic, right-sided, epicardial ablation was performed, with a goal of creating a box lesion on the posterior wall of the left atrium; a novel versapolar radiofrequency (RF) catheter was used. In patients enrolled later, occlusion of the left atrial appendage was also performed. An endocardial procedure was performed 2-4 months later, with the goal of confirming/completing the box lesion and ablating the ganglionated plexi and cavotricuspid isthmus. Efficacy was assessed using multiple 24-h and 1-week Holter monitoring. Analysis was performed to search for variables associated with procedure's failure. RESULTS: Forty-one patients (14 persistent and 27 long-standing persistent AF) were enrolled with a mean AF duration of 33.5 ± 33.1 months. Mean follow-up was 507.2 ± 201.1 days (180-731). At the last follow-up visit, 27(65%) patients were arrhythmia-free, without anti-arrhythmics or need for re-ablation. Additional 4 patients (9.8%) were in sinus rhythm (SR) following re-ablation of postprocedural peri-mitral flutter and 4 (9.8%) were in SR on anti-arrhythmics. Longer periods of preoperative AF were independently associated with worse arrhythmia-free survival (p = 0.015). Serious postoperative complications occurred in 3 (7.3%) patients; only 1 (2.4%) patient had clinical consequences after 6 months. CONCLUSIONS: Hybrid ablation of non-paroxysmal AF using a novel, versapolar RF device yields promising mid-term results. Better arrhythmia-free survival rates were found in AF patients with shorter AF duration.
- Klíčová slova
- Atrial fibrillation, Hybrid ablation, Long-standing persistent, Persistent, Versapolar device,
- MeSH
- bezpečnost vybavení MeSH
- časové faktory MeSH
- chronická nemoc MeSH
- design vybavení MeSH
- elektrokardiografie ambulantní metody MeSH
- elektrokardiografie metody MeSH
- fibrilace síní diagnostické zobrazování chirurgie MeSH
- hodnocení rizik MeSH
- katetrizační ablace přístrojové vybavení metody MeSH
- kohortové studie MeSH
- lidé středního věku MeSH
- lidé MeSH
- monitorování fyziologických funkcí přístrojové vybavení metody MeSH
- následné studie MeSH
- recidiva MeSH
- retrospektivní studie MeSH
- senioři MeSH
- stupeň závažnosti nemoci MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
BACKGROUND: Changes in quality of life (QoL) after catheter ablation for long-standing persistent atrial fibrillation (LSPAF) are not well described. We sought to compare QoL improvement after catheter ablation of paroxysmal atrial fibrillation (PAF) versus that after LSPAF. METHODS AND RESULTS: A total of 261 PAF and 126 LSPAF ablation recipients were prospectively followed for arrhythmia recurrence, QoL, hospital stay, and sick leave. In PAF versus LSPAF groups, 1.3±0.6 versus 1.6±0.7 procedures were performed per patient (P<0.00001) during a 3-year follow-up. Good arrhythmia control was achieved in 86% versus 87% of patients (P=0.69) and in 69% versus 69% of patients not receiving antiarrhythmic drugs (P=0.99). The baseline QoL was better in the PAF than in the LSPAF group (European Quality of Life Group instrument self-report questionnaire visual analog scale: 66.4±14.2 versus 61.0±14.2, P=0.0005; European Quality of Life Group 3-level, 5-dimensional descriptive system: 71.4±9.2 versus 67.7±13.8, P=0.002). Postablation 3-year increase in QoL was significant in both groups (all P<0.00001) and significantly lower in PAF versus LSPAF patients (visual analog scale: +5.0±14.5 versus +10.2±12.8, P=0.001; descriptive system: +5.9±14.3 versus +9.3±13.9, P=0.03). In multivariate analysis, LSPAF, less advanced age, shorter history of AF and good arrhythmia control were consistently associated with postablation 3-year improvement in QoL. Days of hospital stay for cardiovascular reasons and days on sick leave per patient/year were significantly reduced in both groups. CONCLUSIONS: Patients with LSPAF had worse baseline QoL. The magnitude of QoL improvement after ablation of LSPAF was significantly greater compared with after ablation of PAF, particularly when good arrhythmia control was achieved without the use of antiarrhythmic drugs.
- Klíčová slova
- atrial fibrillation, long‐standing persistent, paroxysmal, quality of life,
- MeSH
- činnosti denního života MeSH
- deprese MeSH
- dospělí MeSH
- fibrilace síní patofyziologie chirurgie MeSH
- hospitalizace statistika a číselné údaje MeSH
- katetrizační ablace * MeSH
- kohortové studie MeSH
- kvalita života * MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladý dospělý MeSH
- následné studie MeSH
- pracovní neschopnost statistika a číselné údaje MeSH
- prospektivní studie MeSH
- recidiva MeSH
- senioři MeSH
- úzkost MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mladý dospělý MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- srovnávací studie MeSH
BACKGROUND: Catheter ablation of persistent atrial fibrillation yields an unsatisfactorily high number of failures. The hybrid approach has recently emerged as a technique that overcomes the limitations of both surgical and catheter procedures alone. METHODS AND RESULTS: We investigated the sequential (staged) hybrid method, which consists of a surgical thoracoscopic radiofrequency ablation procedure followed by radiofrequency catheter ablation 6 to 8 weeks later using the CARTO 3 mapping system. Fifty consecutive patients (mean age 62±7 years, 32 males) with long-standing persistent atrial fibrillation (41±34 months) and a dilated left atrium (>45 mm) were included and prospectively followed in an unblinded registry. During the electrophysiological part of the study, all 4 pulmonary veins were found to be isolated in 36 (72%) patients and a complete box-lesion was confirmed in 14 (28%) patients. All gaps were successfully re-ablated. Twelve months after the completed hybrid ablation, 47 patients (94%) were in normal sinus rhythm (4 patients with paroxysmal atrial fibrillation required propafenone and 1 patient underwent a redo catheter procedure). The majority of arrhythmias recurred during the first 3 months. Beyond 12 months, there were no arrhythmia recurrences detected. The surgical part of the procedure was complicated by 7 (13.7%) major complications, while no serious adverse events were recorded during the radiofrequency catheter part of the procedure. CONCLUSIONS: The staged hybrid epicardial-endocardial treatment of long-standing persistent atrial fibrillation seems to be extremely effective in maintenance of normal sinus rhythm compared to radiofrequency catheter or surgical ablation alone. Epicardial ablation alone cannot guarantee durable transmural lesions. CLINICAL TRIAL REGISTRATION: URL: www.ablace.cz Unique identifier: cz-060520121617.
- Klíčová slova
- hybrid approach, persistent atrial fibrillation, radiofrequency ablation, sequential, surgical treatment,
- MeSH
- antiarytmika terapeutické užití MeSH
- časové faktory MeSH
- elektrofyziologické techniky kardiologické MeSH
- endokard patofyziologie chirurgie MeSH
- fibrilace síní diagnóza patofyziologie chirurgie MeSH
- Kaplanův-Meierův odhad MeSH
- katetrizační ablace škodlivé účinky metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- perikard patofyziologie chirurgie MeSH
- přežití po terapii bez příznaků nemoci MeSH
- prospektivní studie MeSH
- recidiva MeSH
- registrace MeSH
- reoperace MeSH
- senioři MeSH
- venae pulmonales patofyziologie chirurgie MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- práce podpořená grantem MeSH
- Názvy látek
- antiarytmika MeSH
OBJECTIVES: The treatment of persistent and long-standing persistent atrial fibrillation (AF) has unsatisfactory results using both medical therapy and/or catheter ablation, where incomplete ablation lines remain a significant problem. This study evaluates the feasibility, efficacy and safety of the sequential, two-staged hybrid treatment combining thoracoscopic surgical and transvenous catheter AF ablation. METHODS: Thirty patients with persistent and long-standing persistent AF underwent surgical thoracoscopic radiofrequency (RF) ablation procedure using a predefined protocol (pulmonary veins isolation, box lesion, isthmus line lesion, dissection of the ligament of Marshall, left atrial appendage exclusion with an epicardial clip and ganglionated plexi ablation) followed by diagnostic catheterization and RF ablation 3 months later. In this session, electrical mapping of the left atrium was performed and any incomplete isolation lines were completed. Mitral and cavotricuspid isthmus ablation lines were performed during this session as well. RESULTS: The preoperative mean duration time of AF was 33 ± 27 months with 17% patients with persistent and 83% patients with long-standing persistent AF. The mean size of the left atrium was 48 ± 5 mm. The complete surgical ablation protocol was achieved in 97% of patients, with no death, and no early stroke or pacemaker implantation in the early postoperative period. In 63% of patients, the left atrial appendage was excluded with an epicardial clip. An endocardial touch-up for achievement of bidirectional block of pulmonary veins was necessary in 10 patients (33%) and on the box, (roof and floor) lesions in 20 patients (67%). Freedom from atrial fibrillation was 77% after surgical ablation and 93% after the completed hybrid procedure. CONCLUSIONS: The sequential, two-staged hybrid strategy (surgical thoracoscopic followed by catheter ablation) is feasible and safe with a high post-procedural success and seems to represent the optimal treatment with low risk load and potentially long-term benefit for patients with a persistent and long-standing persistent form atrial fibrillation.
- Klíčová slova
- Atrial fibrillation, Hybrid procedure, Persistent, Radiofrequency ablation, Surgical treatment,
- MeSH
- časové faktory MeSH
- fibrilace síní diagnóza patofyziologie chirurgie MeSH
- katetrizační ablace * škodlivé účinky MeSH
- lidé středního věku MeSH
- lidé MeSH
- recidiva MeSH
- senioři MeSH
- studie proveditelnosti MeSH
- torakoskopie * škodlivé účinky MeSH
- výsledek terapie MeSH
- Check Tag
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH
- hodnotící studie MeSH
- práce podpořená grantem MeSH
Left atrial (LA) volume (LAV) is used for the selection of patients with atrial fibrillation (AF) to rhythm control strategies. Calculation of LAV from the LA diameters and areas by two-dimensional (2D) echocardiography may result in significant error. Accuracy of atrial volume assessment has never been studied in patients with long-standing persistent AF (LSPAF) and significant atrial remodeling. This study investigated correlation and agreement between 2D echocardiographic (Simpson method) and electroanatomic (CARTO, Biosense Webster) left and right atrial (RA) volumes (LAV(ECHO) vs. LAV(CARTO) and RAV(ECHO) vs. RAV(CARTO)) in patients undergoing catheter ablation for LSPAF. The study enrolled 173 consecutive subjects (females: 21 %, age: 59+/-9 years). There was only modest correlation between LAV(ECHO) (92+/-31 ml) and LAV(CARTO) (178+/-37 ml) (R=0.57), and RAV(ECHO) (71+/-29 ml) and RAV(CARTO) (173+/-34 ml) (R=0.42), respectively. LAV(ECHO) and RAV(ECHO) underestimated LAV(CARTO) and RAV(CARTO) with the absolute bias (+/-1.96 standard deviation) of -85 (-148; -22) ml and -102 (-169; -35) ml, respectively, and with the relative bias of -48 (-75; -21) % and -59 (-88; -30) %, respectively (all P<0.000001 for their mutual difference). Significant confounders of this difference were not identified. In patients with LSPAF, 2D echocardiography significantly underestimated both LA and RA volumes as compared with electroanatomic reference. This disagreement was independent of clinical, echocardiographic and mapping characteristics.
- MeSH
- chirurgie s pomocí počítače metody MeSH
- dospělí MeSH
- echokardiografie metody MeSH
- fibrilace síní diagnostické zobrazování patologie chirurgie MeSH
- katetrizační ablace metody MeSH
- lidé středního věku MeSH
- lidé MeSH
- mapování potenciálů tělesného povrchu metody MeSH
- reprodukovatelnost výsledků MeSH
- retrospektivní studie MeSH
- senioři MeSH
- senzitivita a specificita MeSH
- srdeční síně diagnostické zobrazování patologie chirurgie MeSH
- velikost orgánu MeSH
- výsledek terapie MeSH
- Check Tag
- dospělí MeSH
- lidé středního věku MeSH
- lidé MeSH
- mužské pohlaví MeSH
- senioři MeSH
- ženské pohlaví MeSH
- Publikační typ
- časopisecké články MeSH