-
Je něco špatně v tomto záznamu ?
Adsorptive stripping voltammetric determination of 1,1-dimethyl-3-phenyltriazene
Ljubiša M. Ignjatović Jiří Barek, Jiří Zima, Milica C. Stević
Jazyk angličtina Země Česko
NLK
ProQuest Central
od 2005-01-01 do 2011
- MeSH
- elektrochemie metody přístrojové vybavení MeSH
- elektrody MeSH
- financování organizované MeSH
- karcinogeny životního prostředí analýza MeSH
- látky znečišťující životní prostředí analýza MeSH
- triazeny analýza MeSH
The optimum conditions were found for the determination of 1,1-dimethyl-3-phenyltriazene in the concentration range from 1 × 10-4 to 1 × 10-7 mol l-1 by differential pulse voltammetry at a hanging mercury drop electrode. The sensitivity of the determination can be improved by preliminary adsorptive accumulation of the substance on the surface of the hanging mercury drop. Differential pulse adsorptive stripping voltammetry can be used for the purpose in the concentration range from 1 × 10-6 to 1 × 10-9 mol l-1. The determination limit is 1 × 10-9 mol l-1 for a deposition time of 10 min, the relative standard deviation being 5% (n = 10) for a concentration of 2 × 10-9 mol l-1.
Lit.: 19
- 000
- 02302naa 2200385 a 4500
- 001
- bmc07505544
- 003
- CZ-PrNML
- 005
- 20111210122339.0
- 008
- 080619s2008 xr e eng||
- 009
- AR
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Ignjatoavic, Ljubiča M.
- 245 10
- $a Adsorptive stripping voltammetric determination of 1,1-dimethyl-3-phenyltriazene / $c Ljubiša M. Ignjatović Jiří Barek, Jiří Zima, Milica C. Stević
- 314 __
- $a Faculty of Physical Chemistry, University of Belgrade, Belgrade
- 504 __
- $a Lit.: 19
- 520 9_
- $a The optimum conditions were found for the determination of 1,1-dimethyl-3-phenyltriazene in the concentration range from 1 × 10-4 to 1 × 10-7 mol l-1 by differential pulse voltammetry at a hanging mercury drop electrode. The sensitivity of the determination can be improved by preliminary adsorptive accumulation of the substance on the surface of the hanging mercury drop. Differential pulse adsorptive stripping voltammetry can be used for the purpose in the concentration range from 1 × 10-6 to 1 × 10-9 mol l-1. The determination limit is 1 × 10-9 mol l-1 for a deposition time of 10 min, the relative standard deviation being 5% (n = 10) for a concentration of 2 × 10-9 mol l-1.
- 650 _2
- $a elektrochemie $x metody $x přístrojové vybavení $7 D004563
- 650 _2
- $a elektrody $7 D004566
- 650 _2
- $a látky znečišťující životní prostředí $x analýza $7 D004785
- 650 _2
- $a triazeny $x analýza $7 D014226
- 650 _2
- $a karcinogeny životního prostředí $x analýza $7 D002274
- 650 _2
- $a financování organizované $7 D005381
- 700 1_
- $a Barek, Jiří, $d 1949- $7 jn20000400068
- 700 1_
- $a Zima, Jiří, $d 1956- $7 jn20000402749
- 700 1_
- $a Stevic, Milica C.
- 773 0_
- $w MED00010973 $t Collection of Czechoslovak chemical communications $g Roč. 73, č. 1 (2008), s. 97-106 $x 0010-0765
- 910 __
- $a ABA008 $b A 1006 $c 394 $y 1
- 990 __
- $a 20080619164908 $b ABA008
- 991 __
- $a 20080619193332 $b ABA008
- 999 __
- $a ok $b bmc $g 621168 $s 473601
- BAS __
- $a 3
- BMC __
- $a 2008 $b 73 $c 1 $d 97-106 $i 0010-0765 $m Collection of Czechoslovak Chemical Communications $x MED00010973
- LZP __
- $a 2008-10/dkmv