ECG body surface mapping (BSM) in type 1 diabetic patients
Denisa Žďárská, Petra Pelíšková, Jiří Charvát, Jaroslav Slavíček, Mikuláš Mlček, Eva Medová, Otomar Kittnar
Language English Country Czech Republic
NLK
Directory of Open Access Journals
from 1991
Free Medical Journals
from 1998
ProQuest Central
from 2005-01-01
Medline Complete (EBSCOhost)
from 2006-01-01
Nursing & Allied Health Database (ProQuest)
from 2005-01-01
Health & Medicine (ProQuest)
from 2005-01-01
ROAD: Directory of Open Access Scholarly Resources
from 1998
- MeSH
- Diabetes Mellitus MeSH
- Electrocardiography methods utilization MeSH
- Financing, Organized utilization MeSH
- Data Interpretation, Statistical MeSH
- Insulin therapeutic use MeSH
- Cardiovascular Diseases diagnosis complications MeSH
- Body Surface Potential Mapping methods utilization MeSH
- Vectorcardiography methods utilization MeSH
Diabetes mellitus is a risk factor of cardiovascular diseases. ECG of patients with diabetes mellitus type 1 (DM 1) shows tachycardia (block of parasympathetic innervation) and abnormal repolarization (increased QT interval and QT dispersion (QTd)) indicating a risk of ventricular tachycardia and sudden death in young people with DM 1. The aim of the present report was to measure 145 parameters of the heart electric field in 22 patients (14 men, 8 women) with DM 1 without complications (mean age 32.8±11.4 years) and in 22 controls (11 men, 11 women, mean age 30.1±3.4 years). The duration of diabetes was 13.9±7.8 years. The parameters were registered by the diagnostic system Cardiag 112.2 and statistically evaluated by the Student and Mann-Whitney test. Tachycardia (86.3±2.7 beats.min-1), shortening of both QRS (79.9±1.6 ms) and QT (349.0±5.9 ms) and increased QT dispersion (115±36 ms) were observed in DM 1 when compared with the controls (75.0±2.1 beats. min.-1, QRS 89.9±2.7 ms, QT 374.0±4.4 ms, QTd 34.0±12.0 ms, p<0.01). The QTc was 415.2±4.1 ms in DM 1 and 401.4±6.6 ms in controls (NS). Other significant findings in DM 1 were: higher maximum of depolarization isopotential maps (DIPMmax) in the initial phase of QRS and less positive in the terminal phase, more negative minimum (DIPMmin) during QRS similarly as the minimum in depolarization isointegral maps (DIIMmin) and the minimum in isointegral map of the Q wave (Q-IIMmin), lower maximum in repolarization isopotential maps (RIPMmax) and less negative minimum (RIPMmin), more negative amplitude of Q wave (Q-IPMAM) and more pronounced spread of depolarization (activation time). Our results confirmed a decreased parasympathetic to sympathetic tone ratio (tachycardia, shortening of the activation time) and revealed different depolarization and repolarization patterns in DM 1. The differences in heart electric field parameters measured by the BSPM method in DM 1 and in the controls indicate the importance of ECG examination of diabetic patients type 1 in the prevention of cardiovascular diseases.
Lit.: 41
- 000
- 04111naa 2200457 a 4500
- 001
- bmc07509082
- 003
- CZ-PrNML
- 005
- 20111210123413.0
- 008
- 080919s2007 xr e eng||
- 009
- AR
- 040 __
- $a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a xr
- 100 1_
- $a Janíčková Žďárská, Denisa $7 xx0074326
- 245 10
- $a ECG body surface mapping (BSM) in type 1 diabetic patients / $c Denisa Žďárská, Petra Pelíšková, Jiří Charvát, Jaroslav Slavíček, Mikuláš Mlček, Eva Medová, Otomar Kittnar
- 314 __
- $a Dept. Med., Second Med. Fac., Charles Univ., Prague
- 504 __
- $a Lit.: 41
- 520 9_
- $a Diabetes mellitus is a risk factor of cardiovascular diseases. ECG of patients with diabetes mellitus type 1 (DM 1) shows tachycardia (block of parasympathetic innervation) and abnormal repolarization (increased QT interval and QT dispersion (QTd)) indicating a risk of ventricular tachycardia and sudden death in young people with DM 1. The aim of the present report was to measure 145 parameters of the heart electric field in 22 patients (14 men, 8 women) with DM 1 without complications (mean age 32.8±11.4 years) and in 22 controls (11 men, 11 women, mean age 30.1±3.4 years). The duration of diabetes was 13.9±7.8 years. The parameters were registered by the diagnostic system Cardiag 112.2 and statistically evaluated by the Student and Mann-Whitney test. Tachycardia (86.3±2.7 beats.min-1), shortening of both QRS (79.9±1.6 ms) and QT (349.0±5.9 ms) and increased QT dispersion (115±36 ms) were observed in DM 1 when compared with the controls (75.0±2.1 beats. min.-1, QRS 89.9±2.7 ms, QT 374.0±4.4 ms, QTd 34.0±12.0 ms, p<0.01). The QTc was 415.2±4.1 ms in DM 1 and 401.4±6.6 ms in controls (NS). Other significant findings in DM 1 were: higher maximum of depolarization isopotential maps (DIPMmax) in the initial phase of QRS and less positive in the terminal phase, more negative minimum (DIPMmin) during QRS similarly as the minimum in depolarization isointegral maps (DIIMmin) and the minimum in isointegral map of the Q wave (Q-IIMmin), lower maximum in repolarization isopotential maps (RIPMmax) and less negative minimum (RIPMmin), more negative amplitude of Q wave (Q-IPMAM) and more pronounced spread of depolarization (activation time). Our results confirmed a decreased parasympathetic to sympathetic tone ratio (tachycardia, shortening of the activation time) and revealed different depolarization and repolarization patterns in DM 1. The differences in heart electric field parameters measured by the BSPM method in DM 1 and in the controls indicate the importance of ECG examination of diabetic patients type 1 in the prevention of cardiovascular diseases.
- 650 _2
- $a diabetes mellitus $7 D003920
- 650 _2
- $a kardiovaskulární nemoci $x diagnóza $x komplikace $7 D002318
- 650 _2
- $a elektrokardiografie $x metody $x využití $7 D004562
- 650 _2
- $a mapování potenciálů tělesného povrchu $x metody $x využití $7 D018780
- 650 _2
- $a inzulin $x terapeutické užití $7 D007328
- 650 _2
- $a vektorkardiografie $x metody $x využití $7 D014672
- 650 _2
- $a interpretace statistických dat $7 D003627
- 650 _2
- $a financování organizované $x využití $7 D005381
- 700 1_
- $a Pelíšková, Pavlína $7 xx0103857
- 700 1_
- $a Charvát, Jiří, $d 1948- $7 pna2005261832
- 700 1_
- $a Slavíček, Jaroslav, $d 1939- $7 jo2002101780
- 700 1_
- $a Mlček, Mikuláš $7 xx0106453
- 700 1_
- $a Medová, Eva $7 xx0066278
- 700 1_
- $a Kittnar, Otomar, $d 1953- $7 jn20000710185
- 773 0_
- $w MED00003824 $t Physiological research $g Roč. 56, č. 4 (2007), s. 403-410 $x 0862-8408
- 856 41
- $u http://www.biomed.cas.cz/physiolres/pdf/56/56_403.pdf $y plný text volně přístupný
- 910 __
- $a ABA008 $b A 4120 $c 266 $y 1
- 990 __
- $a 20080919102413 $b ABA008
- 991 __
- $a 20080919113112 $b ABA008
- 999 __
- $a ok $b bmc $g 624676 $s 477111
- BAS __
- $a 3
- BMC __
- $a 2007 $b 56 $c 4 $d 403-410 $i 0862-8408 $m Physiological research $x MED00003824
- LZP __
- $a 2008-21/dkal