Comparison of posterior capsule opacification after two different surgical methods of cataract extraction

J Nekolova, J Pozlerova, N Jiraskova, P Rozsival, J Kadlecova

. 2008 ; 145 (3) : 493-498.

Jazyk angličtina Země Spojené státy americké

Typ dokumentu srovnávací studie

Perzistentní odkaz   https://www.medvik.cz/link/bmc10026979
E-zdroje Online

NLK ScienceDirect (archiv) od 1993-01-01 do 2009-12-31

PURPOSE: To compare the extent of posterior capsule opacification (PCO) after AquaLase and NeoSoniX phacoemulsification methods using two types of software for PCO quantification. DESIGN: Prospective, randomized clinical trial. METHODS: At the Department of Ophthalmology, University Hospital in Hradec Kralove, 50 patients (100 eyes) were analyzed one year after surgery. AquaLase was used in the right eye and NeoSoniX in the left eye of each patient. One year after surgery, digital retroillumination photographs of anterior segments were obtained. The Evaluation of Posterior Capsule Opacification (EPCO) 2000 software (Berlin, Germany) and the Open-Access Systematic Capsule Assessment (OSCA) system (Edinburgh, United Kingdom) were used for PCO assessment. Best-corrected Snellen visual acuity (BCVA) was evaluated before and after surgery. Statistical analysis was performed using parametric tests. RESULTS: The EPCO 2000 results were as follows: mean value for right eyes, 0.324+/-0.305; mean value for left eyes, 0.298+/-0.341; no difference was proved (P=.532). The OSCA results were as follows: for right eyes, 0.7097+/-0.3777; for left eyes, 0.8584+/-0.4323; significant difference (P=.046), worse for left eyes. No correlation between EPCO 2000 and OSCA results was established (P>.001; correlation coefficient, 0.347). BCVA for the right eyes was 0.837+/-0.262 and for the left eyes was 0.849+/-0.224. Neodymium:yytrium-aluminum-garnet capsulotomy was performed in one eye in the NeoSoniX group, and in no eyes in the AquaLase group. CONCLUSIONS: There was no significant difference in PCO measured by EPCO 2000, however, PCO after AquaLase as assessed by EPCO 2000 was slightly denser. The OSCA system gave significantly higher scores in the NeoSoniX group. No correlation between EPCO 2000 and OSCA outcomes was proved.

000      
00000naa 2200000 a 4500
001      
bmc10026979
003      
CZ-PrNML
005      
20111210192521.0
008      
101020s2008 xxu e eng||
009      
AR
040    __
$a ABA008 $b cze $c ABA008 $d ABA008 $e AACR2
041    0_
$a eng
044    __
$a xxu
100    1_
$a Nekolová, Jana. $7 xx0237420
245    10
$a Comparison of posterior capsule opacification after two different surgical methods of cataract extraction / $c J Nekolova, J Pozlerova, N Jiraskova, P Rozsival, J Kadlecova
314    __
$a Department of Ophthalmology, University Hospital in Hradec Kralove, Hradec Kralove, Czech Republic. jani.nekolova@seznam.cz
520    9_
$a PURPOSE: To compare the extent of posterior capsule opacification (PCO) after AquaLase and NeoSoniX phacoemulsification methods using two types of software for PCO quantification. DESIGN: Prospective, randomized clinical trial. METHODS: At the Department of Ophthalmology, University Hospital in Hradec Kralove, 50 patients (100 eyes) were analyzed one year after surgery. AquaLase was used in the right eye and NeoSoniX in the left eye of each patient. One year after surgery, digital retroillumination photographs of anterior segments were obtained. The Evaluation of Posterior Capsule Opacification (EPCO) 2000 software (Berlin, Germany) and the Open-Access Systematic Capsule Assessment (OSCA) system (Edinburgh, United Kingdom) were used for PCO assessment. Best-corrected Snellen visual acuity (BCVA) was evaluated before and after surgery. Statistical analysis was performed using parametric tests. RESULTS: The EPCO 2000 results were as follows: mean value for right eyes, 0.324+/-0.305; mean value for left eyes, 0.298+/-0.341; no difference was proved (P=.532). The OSCA results were as follows: for right eyes, 0.7097+/-0.3777; for left eyes, 0.8584+/-0.4323; significant difference (P=.046), worse for left eyes. No correlation between EPCO 2000 and OSCA results was established (P>.001; correlation coefficient, 0.347). BCVA for the right eyes was 0.837+/-0.262 and for the left eyes was 0.849+/-0.224. Neodymium:yytrium-aluminum-garnet capsulotomy was performed in one eye in the NeoSoniX group, and in no eyes in the AquaLase group. CONCLUSIONS: There was no significant difference in PCO measured by EPCO 2000, however, PCO after AquaLase as assessed by EPCO 2000 was slightly denser. The OSCA system gave significantly higher scores in the NeoSoniX group. No correlation between EPCO 2000 and OSCA outcomes was proved.
650    _2
$a dospělí $7 D000328
650    _2
$a senioři $7 D000368
650    _2
$a senioři nad 80 let $7 D000369
650    _2
$a přední segment oční $x patologie $7 D000869
650    _2
$a katarakta $x etiologie $7 D002386
650    _2
$a ženské pohlaví $7 D005260
650    _2
$a lidé $7 D006801
650    _2
$a pouzdro oční čočky $x patologie $7 D007903
650    _2
$a implantace nitrooční čočky $7 D019654
650    _2
$a mužské pohlaví $7 D008297
650    _2
$a lidé středního věku $7 D008875
650    _2
$a fakoemulzifikace $x metody $7 D018918
650    _2
$a pooperační komplikace $7 D011183
650    _2
$a prospektivní studie $7 D011446
650    _2
$a software $7 D012984
650    _2
$a zraková ostrost $7 D014792
650    _2
$a randomizované kontrolované studie jako téma $7 D016032
650    _2
$a financování organizované $7 D005381
655    _2
$a srovnávací studie $7 D003160
700    1_
$a Pozlerová, Jana, $d 1981- $7 xx0139721
700    1_
$a Jirásková, Naďa, $d 1965- $7 mzk2007395044
700    1_
$a Rozsíval, Pavel, $d 1950- $7 nlk19990073794
700    1_
$a Kadlecová, Jana, $d 1974- $7 xx0078413
773    0_
$w MED00000272 $t American journal of ophthalmology $g Roč. 145, č. 3 (2008), s. 493-498 $x 0002-9394
910    __
$a ABA008 $b A 615 $y 7
990    __
$a 20110223105807 $b ABA008
991    __
$a 20110413082817 $b ABA008
999    __
$a ok $b bmc $g 802085 $s 666845
BAS    __
$a 3
BMC    __
$a 2008 $b 145 $c 3 $d 493-498 $i 0002-9394 $m American journal of ophthalmology $n Am J Ophthalmol $x MED00000272
LZP    __
$a 2011-2B/ewme

Najít záznam

Citační ukazatele

Nahrávání dat ...

    Možnosti archivace