Something wrong with this record ?
The influence of orifice height on flow rate of powder excipients
Z. Zatloukal, Z. Sklubalová
Language English Country Germany
Document type Journal Article, Research Support, Non-U.S. Gov't
PubMed
22312701
Knihovny.cz E-resources
- MeSH
- Sodium Chloride MeSH
- Technology, Pharmaceutical standards MeSH
- Boric Acids MeSH
- Excipients MeSH
- Powders MeSH
- Reproducibility of Results MeSH
- Temperature MeSH
- Particle Size MeSH
- Vibration MeSH
- Humidity MeSH
- Publication type
- Journal Article MeSH
- Research Support, Non-U.S. Gov't MeSH
The influence of the orifice height of a cylindrical, flat-bottomed hopper on the mass flow rate of the free-flowable size fractions of sodium chloride and boric acid was investigated. It was observed that a zone of sudden acceleration of the mass flow under gravity occurred when a critical orifice height had been achieved. Based on the results, an orifice diameter equal to 12 mm with a height of between 8-16 mm is recommended for the faster flow of sodium chloride while an orifice diameter equal to 8 mm with a height of less than 8mm is appropriate for the slower flow of boric acid. In summary, the orifice height should be taken into consideration as an important parameter of a cylindrical test hopper in order to obtain a reproducible and comparable mass flow as the single-point characteristic of powder flowability.
- 000
- 00000naa a2200000 a 4500
- 001
- bmc12022544
- 003
- CZ-PrNML
- 005
- 20160321110752.0
- 007
- ta
- 008
- 120806s2011 gw f 000 0#eng||
- 009
- AR
- 035 __
- $a (PubMed)22312701
- 040 __
- $a ABA008 $b cze $d ABA008 $e AACR2
- 041 0_
- $a eng
- 044 __
- $a gw
- 100 1_
- $a Zatloukal, Zdeněk $u Department of Pharmaceutical Technology, Charles University in Prague, Faculty of Pharmacy in Hradec Králové, Czech Republic $7 xx0113002
- 245 14
- $a The influence of orifice height on flow rate of powder excipients / $c Z. Zatloukal, Z. Sklubalová
- 520 9_
- $a The influence of the orifice height of a cylindrical, flat-bottomed hopper on the mass flow rate of the free-flowable size fractions of sodium chloride and boric acid was investigated. It was observed that a zone of sudden acceleration of the mass flow under gravity occurred when a critical orifice height had been achieved. Based on the results, an orifice diameter equal to 12 mm with a height of between 8-16 mm is recommended for the faster flow of sodium chloride while an orifice diameter equal to 8 mm with a height of less than 8mm is appropriate for the slower flow of boric acid. In summary, the orifice height should be taken into consideration as an important parameter of a cylindrical test hopper in order to obtain a reproducible and comparable mass flow as the single-point characteristic of powder flowability.
- 650 _2
- $a kyseliny borité $7 D001888
- 650 _2
- $a pomocné látky $7 D005079
- 650 _2
- $a vlhkost $7 D006813
- 650 _2
- $a velikost částic $7 D010316
- 650 _2
- $a prášky, zásypy, pudry $7 D011208
- 650 _2
- $a reprodukovatelnost výsledků $7 D015203
- 650 _2
- $a chlorid sodný $7 D012965
- 650 _2
- $a farmaceutická technologie $x normy $7 D013678
- 650 _2
- $a teplota $7 D013696
- 650 _2
- $a vibrace $7 D014732
- 655 _2
- $a časopisecké články $7 D016428
- 655 _2
- $a práce podpořená grantem $7 D013485
- 700 1_
- $a Šklubalová, Zdeňka $7 xx0223583
- 773 0_
- $w MED00003807 $t Die Pharmazie $x 0031-7144 $g Roč. 66, č. 12 (2011), s. 953-955
- 856 41
- $u https://pubmed.ncbi.nlm.nih.gov/22312701 $y Pubmed
- 910 __
- $a ABA008 $b sig $c sign $y m $z 0
- 990 __
- $a 20120806 $b ABA008
- 991 __
- $a 20160321110818 $b ABA008
- 999 __
- $a ok $b bmc $g 944457 $s 779841
- BAS __
- $a 3
- BAS __
- $a PreBMC
- BMC __
- $a 2011 $b 66 $c 12 $d 953-955 $i 0031-7144 $m Die Pharmazie $n Pharmazie $x MED00003807
- LZP __
- $b NLK111 $a Pubmed-20120806/12/01